http://www.vericable.com/cables/overheadcable/85.htm
Aerial Cable
Http://www.Zmscable.Com/overheadcables/325.Html -
Aerial Cable
http://www.zmscable.com/overheadcables/325.html
Power cable Spaced Aerial Cable, SAC 15kV, 25kV, 35kV
(1).Application: ABC Cable Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crosslinked polyethylene(XLP)insulated conductors. (2).Construction: Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+ Size (AWG) Stranding Insul. Thick. (Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY AAC Neutral-messenger Pekingese 6 1 45 6 7 563 10.36 61 61 85 70 Collie 6 7 45 6 7 563 10.36 64 64 85 70 Dachshund 4 1 45 4 7 881 10.36 92 92 115 90 Spaniel 4 7 45 4 7 881 10.36 96 96 115 90 Doberman 2 7 45 2 7 1350 14.88 147 147 150 120 Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160 Wooden Drum.
1.Application The NFC33-209 Standard AAAC Conductor Aerial Cable is used for 600V or lower overhead service applications such as power transimission and distribution for street lighting,outdoor lighting,and temporary service for construction. The operating temperatures should not to exceed 75°C for polyethylene(PE) insulated conductors or 90°C for crosslinked polyethylene(XLPE)insulated conductors. 2.Standard : NFC33-209,BS7870,GB/T12527-2008 3.Rated voltage : 1kV,10kV or 11kV 4.Specification Concentric strand Aluminum/ AlloyAAAC wires insulated by PE or XLPE as phase conductor, bare or insulated AAC/AAAC/ACSR/AACSR messenger
Place of Origin -Hebei, China Model Number -PTC Product Name -ABC Aerial Cable Accessories Certificate -ISO9001,ROHS,Test Report Material -PA66, Aluminum Alloy OEM/ODM -Offer Usage -Electrical Cable Fitting Kechen -ABC Accessories Factory
Place of Origin -Hebei, China Model Number -PTC Product Name -ABC Aerial Cable Accessories Certificate -ISO9001,ROHS,Test Report Material -PA66, Aluminum Alloy OEM/ODM -Offer Usage -Electrical Cable Fitting Kechen -ABC Accessories Factory
http://www.xlpecable.com/zmscable/abc_272_1.html
ABC Cable Aerial Bundle Cable
http://www.xlpecable.com/zmscable/abc_272_1.html
1.Application The NFC33-209 Standard AAAC Conductor Aerial Cable is used for 600V or lower overhead service applications such as power transimission and distribution for street lighting,outdoor lighting,and temporary service for construction. The operating temperatures should not to exceed 75°C for polyethylene(PE) insulated conductors or 90°C for crosslinked polyethylene(XLPE)insulated conductors. 2.Standard : NFC33-209,BS7870,GB/T12527-2008 3.Rated voltage : 1kV,10kV or 11kV 4.Specification Concentric strand Aluminum/ AlloyAAAC wires insulated by PE or XLPE as phase conductor, bare or insulated AAC/AAAC/ACSR/AACSR messenger
Cable Solid polyethylene insulated Self supporting aerial cables Description: Twisted pair cable with solid polythene insulated copper conductor, jelly filled or no jelly filled, polyester coated aluminum tape (pap) longitudinally wrapped, pe sheathed self-supporting local communication cable Application: This cables is ideal for long distance and interoffice communication for aerial installation. Construction: Conductor Solid annealed copper wire, sizes: 0.4 mm to 0.9 mm. Insulation Pe, color code in accordance with standard telephony industry code. Twisted pairs Insulated conductors twisted into pairs. Varying lay length is designed to minimize the cross talk and capacitance unbalance. Cable core 10 or 25 pairs are stranded to form a group called unit. Units/super units make up cables of 50 pairs and above. Core wrap A non-hygroscopic and dielectric polyester tape is applied helically with a suitable overlap. Screen Electrically continuous 0.2 mm thick aluminium tape coated with co-polymer on both sides applied longitudinally and overlapped to form a moisture barrier. Suspension Strand 7 extra high strength of galvanized steel wires strand together to form the suspension strand. Jacket Black ldpe Identification Length marking Manufacturer's identification, cable type, conductor size, year of manufacture are marked on jacket at one meter intervals (can be also as per customerí»s request) 1000m or 500m per durm.
•relative immunity to short circuits caused by external forces (wind, fallen branches), unless they abrade the insulation. •can stand in close proximity to trees and will not generate sparks if touched. •simpler installation, as crossbars and insulators are not required. •less cluttered appearance. •can be installed in a narrower right-of-way. •at junction poles, insulating bridging wires are needed to connect non-insulated wires at either side. Abc can dispense with one of these splices. •less risk of a neutral-only break from tree or vehicle damage, increasing safety with tnc-s systems. •electricity theft is made harder, and more obvious to detect. Drum or as your request
http://www.vericable.com/cables/overheadcable/aerial-bundle-cable.htm