Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Voltage transducer converts an ac voltage input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.
Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Voltage transducer converts an ac voltage input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage. Specifications Inputs: System voltages 100V,220V, 380V, 450V Absorbed power 0.5VA Frequency range 50Hz, 60Hz Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Ripple
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. Specifications Inputs: System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V Absorbed power 0.1VA Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Respones time
Function & Feature 1. QPPX electrical transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Total four channel output, with panel key or PC control programmable, user can free to set 4 different data from max 26 electrical parameter for sampling and analog signal output. 2. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA software. Any of the measured parameters can be read out via the optional RS485-Modbus connection. 3. QPPX also can be used to configure the connection to the measured circuit for single-phase, three-phase three-wire, three-phase four-wire, balanced or unbalanced load. Can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature 1. QPCX electrical transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt), reactive power (var) and power factor (PF). With an extra output channel for customized. Total four channel output for electrical data sampling use. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. This combination transducers with RS485 communication port, it can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Current transducer converts an ac current input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage. Specifications Inputs: System current 1A, 5A, 10A, 30A Absorbed power 0.3VA Frequency range 50Hz, 60Hz Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Ripple
Function & Feature 1. QPCX electrical transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt), reactive power (var) and power factor (PF). With an extra output channel for customized. Total four channel output for electrical data sampling use. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. This combination transducers with RS485 communication port, it can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Function & Feature 1. QPPX electrical transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Total four channel output, with panel key or PC control programmable, user can free to set 4 different data from max 26 electrical parameter for sampling and analog signal output. 2. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA software. Any of the measured parameters can be read out via the optional RS485-Modbus connection. 3. QPPX also can be used to configure the connection to the measured circuit for single-phase, three-phase three-wire, three-phase four-wire, balanced or unbalanced load. Can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. 6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Function & Feature 1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. 6. Ultra-thin dimension, suitable for limited space, the control cabinet. Specifications Inputs: System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V Absorbed power 0.1VA Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Respones time
Function & Feature 1. QPK transducer converts ac current and voltage signals into a load independent dc signal proportional to reactive power (vars). This signal is capable of driving a number of independent instruments. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. These var transducers to be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature 1. QPK transducer converts ac current and voltage signals into a load independent dc signal proportional to reactive power (vars). This signal is capable of driving a number of independent instruments. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. These var transducers to be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Function & Feature 1. QPW transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt). This signal is capable of driving a number of independent instruments. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. These watt transducers to be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Function & Feature 1. QPWK transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt) and reactive power (var). Two output signals combination in one transducer. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. This var transducers to be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Input Voltage 12V / 24V DC optional Output Voltage 115V / 230V AC optional Portable power for AC products, AC outlets for connecting multiple loads High surge capacity for products that require more power to start High efficiency converts virtually all of the battery's power to AC Mounting brackets for convenient installation Heavy duty stud-connection mounting RS232 communication port WIFI/BMS Optional Overload and over temperature shut down Low voltage and over voltage alarm/cut off Input reverse protection Short circuit protection PI15 series is a pure sine wave inverter, high frequency machine solution, the product is small size, the solution is reliable and stable, the main function is to invert the DC 12VDC battery or 24VDC battery to AC 230VAC or AC 115VAC output, mainly used for emergency use Electricity, car inverter, outdoor electricity and other occasions.
Introduction AC grid transducer converts an ac voltage or current input into a load independent output signal. With excellent temperature characteristic and good working stability. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.
Features : 3 times peak power, excellent loading capability. Combine inverter/solar controller/battery all in one. Multiple output : 2*AC output socket, 4*DC 12V, 2* Working mode AC prior/ECO mode/Solar prior selectable AC charging current 0 1 0A selectable. LVD/HVD/Charging voltage adjutable, suitable for kinds of battery Adding fault code to monitor real time work situations Continuous stable p ure sine wave output with inbuilt AVR stabilizer . Digital LCD and LED for visualization of operation status of the equipment. Inbuilt automatic AC charger and AC mains switcher, stwitch time 4ms
Function & Feature 1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.