Features Up to 11.3Gb/s data links DWDM EML transmitter and APD receiver 50 GHz ITU channel spacing with integrated wavelength locker Up to 80km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~+70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC Applications 10GBASE-ZR/ZW & 10G Ethernet SDH STM64 Other Optical Links
Features Up to 11.3Gb/s data links DWDM EML transmitter and APD receiver 100 GHz ITU channel spacing with integrated wavelength locker Up to 80km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70 oC Extended: -10 ~ +80 oC Applications 10GBASE-ZR/ZW & 10G Ethernet SDH STM64 Other Optical Links
Up to 11.3Gb/s data links CWDM EML transmitter and APD receiver Up to 80km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC
Features Up to 11.1Gb/s data rate 1490nm DFB laser and APD receiver for HTSX-B495596Zx 1550nm DFB laser and APD receiver for HTSX-B554996Zx 2-wire interface with integrated Digital Diagnostic monitoring Up to 80km transmission on SMF BIDI LC optical connector Single +3.3V power supply Metal enclosure, for lower EMI Maximum power consumption 1.8W RoHS-6 compliant and lead-free SFF-8472 MSA compliant &SFF-8431 Operating case temperature Commercial: 0 ~ +70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC Applications Back to Back 10GBASE-ZR/ZW 10G Ethernet
Up to 11.3Gb/s data links CWDM EML transmitter and APD receiver Up to 80km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC
Up to 11.3Gb/s data links CWDM EML transmitter and APD receiver Up to 80km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC
Features Up to 11.3Gb/s data links DWDM EML transmitter and PIN receiver 50 GHz ITU channel spacing with integrated wavelength locker Up to 40km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC Applications 10GBASE-ER/EW & 10G Ethernet SDH STM64 Other Optical Links
Features Up to 11.3Gb/s data links DWDM EML transmitter and PIN receiver 100 GHz ITU channel spacing with integrated wavelength locker Up to 40km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70 oC Extended: -10 ~ +80 oC Industrial: -40 ~ +85 oC Applications 10GBASE-ER/EW & 10G Ethernet SDH STM64 Other Optical Links
Features Up to 11.1Gb/s data rate 1270nm DFB laser and PIN receiver for HXSX-AL6843x 1330nm DFB laser and PIN receiver for HXSX-AL8643x 2-wire interface with integrated Digital Diagnostic monitoring Up to 40km transmission on SMF BIDI LC optical connector Single +3.3V power supply Metal enclosure, for lower EMI Maximum power consumption 1.5W RoHS-6 compliant and lead-free SFF-8472 MSA compliant &SFF-8431 Operating case temperature Commercial: 0 ~ 70oC Applications Back to Back 10GBASE-ER/EW 10G Ethernet
Features Up to 11.1Gb/s data rate 1270nm DFB laser and PIN receiver for HTSX-B273396Lx 1330nm DFB laser and PIN receiver for HTSX-B332796Lx 2-wire interface with integrated Digital Diagnostic monitoring Up to 10km transmission on SMF BIDI LC optical connector Single +3.3V power supply Metal enclosure, for lower EMI Maximum power consumption 1.5W RoHS-6 compliant and lead-free SFF-8472 MSA compliant &SFF-8431 Operating case temperature Commercial: 0 ~ 70oC Applications Back to Back 10GBASE-LR/LW 10G Ethernet
Features Up to 11.1Gb/s data rate 1270nm DFB laser and APD receiver for HTSX-B273396Kx 1330nm DFB laser and APD receiver for HTSX-B332796Kx 2-wire interface with integrated Digital Diagnostic monitoring Up to 60km transmission on SMF BIDI LC optical connector Single +3.3V power supply Metal enclosure, for lower EMI Maximum power consumption 1.5W RoHS-6 compliant and lead-free SFF-8472 MSA compliant &SFF-8431 Operating case temperature Commercial: 0 ~ 70oC Applications Back to Back 10GBASE-ER/EW 10G Ethernet
Features: Supports 9.95 to 11.3Gb/s bit rates Hot-Pluggable Duplex LC connector 100GHz ITU Grid, C Band DWDM EML transmitter,APD photo-detector SMF links up to 80km 2-wire interface for management specifications compliant with SFF 8472 digital diagnostic monitoring interface Power Supply :+3.3V Power consumption
Features Up to 11.3Gb/s data links 1310nm DFB transmitter and PIN receiver with CDR supported 9.95 to 11.3Gb/s reference-free Up to 10km on 9/125µm SMF Hot-pluggable SFP+ footprint Duplex LC/UPC type pluggable optical interface Metal enclosure, for lower EMI RoHS compliant and lead-free Support Digital Diagnostic Monitoring interface Single +3.3V power supply Maximum power consumption 1.5W Compliant with SFF+MSA and SFF8472 Case operating temperature Commercial: 0 ~ +70oC Extended: -10 ~ +80oC Industrial: -40 ~ +85oC Applications 10GBASE-LR/LW & 10G Ethernet SDH STM64 Other Optical Links
Features: Xaui electrical interface: 4 lanes @ 3.125gbit/s Hot z-pluggable Sc-duplex optical receptacle Mdio, dom support Cooled dwdm eml Apd photo-detector Operating case temperature: 0 to 70°c Compliant to ieee 802.3ae 10gbase-zr application Compliant to xenpak msa 3.0 Mechanical footprint: 4.76 x 1.42 x 0.46" Reference: Ieee 802.3ae as 10gbase-zr, xenpak msa release 3.0
10Gbps DWDM 100GHz 80KM SFP+ Transceiver Item NO.:ESDxxX-3LCD80 Date rate: 10G Wavelength:ITU-T C-band Distance:80KM Connector:LC First:SM DDM:YES Place of origin: Made in China Shipping Port: ShenZhen Package type: Individual package or 10pc/package Features Up to 11.1Gbps Data Links/Up to 80km transmission on SMF / DWDM EML Laser and APD receiver/Metal enclosure, for lower EMI/ wire interface with integrated Digital Diagnostic monitoring/ Hot-pluggable SFP+ footprint/Specifications compliant with SFF 8472/ Compliant with SFP+ MSA with LC connector/Single 3.3V power supply/ Case operating temperature range:0°C to 70°C  /Power dissipation < 1.5W / Applications 1.Gigabit Ethernet/Fiber Channel/Switch to Switch interface 2.Switched backplane applications/Router/Server interface 3.Other optical transmission systems
Specification Data rate: 1.25g Wavelength: tx1550/rx1490nm Distance: 80km Interface: lc Fiber: sm Ddm: yes Place of origin: made in china Port:shenzhen Working temperature: commercial: 0â°c to +70â°c;industrial:-40â°c to +85â°c Optical module used in ethernet, sdh, sonet, can be compatible with cisco 2900 series, cisco 4000 series, cisco 5000 series, huawei, the pole into, d-link, zte, hp, juniper and other equipment. Our products require strict testing standards, standard packing form, to provide customers with quality service and timely delivery cycle. Scope of application: switch, ethernet, data center, sdh, sonet, atm Package type: individual package or 10pc/package 10g sfp+ optical transceiver Etu model cisco model product description Esp8592-3lcd03 sfp-10g-sr 10g sfp+ sr mm 850nm 300m lc connector with ddm Esp3192-3lcd02 sfp-10g-lrm 10g sfp+ lr mm 1310nm 220m lc connector with ddm Esp3192-3lcd10 sfp-10g-lr 10g sfp+ lr sm 1310nm 10km lc connector with ddm Esp5592-3lcd40 sfp-10g-er 10g sfp+ er sm 1550nm 40km lc connector with ddm Esp5592-3lcd80 sfp-10g-zr 10g sfp+ zr sm 1550nm 80km lc connector with ddm Sfp optical transceiver Etu model cisco model product description Es8512-3lcd05 glc-sx-mm 1.25g sfp mm 850nm 550m lc connector with ddm Es3112-3lcd10 glc-lh-smd 1.25g sfp sm 1310nm 10km lc connector with ddm Es3112-3lcd40 glc-ex-smd 1.25g sfp sm 1310nm 40km lc connector with ddm Es5512-3lcd80 glc-zx-smd 1.25g sfp sm 1550nm 80km lc connector with ddm Es3103-3lcd2 glc-ge-100fx 155m sfp mm 1310nm 2km lc connector with ddm Es-t1-rj45 glc-t 1000m copper-t rj45 100m
GLsun's DWDM-SFP25G-10-C17-T02 single-mode transceiver is SFP28 25G DWDM 10KM transceiver for duplex optical data communications support up to 25.78Gb/s. It is with the SFP+ 20-pin connector to allow hot plug capability. Digital diagnostic functions are available via an I C. It has built-in clock and data recovery (CDR). This module is designed for single-mode fiber. Compatible Cisco Form Factor SFP28 Max Data Rate 25.78Gb/s Wavelength 1563.86nm~1528.77nm Max Cable Distance 10km Connector Duplex LC Transmitter Type 1563.86nm EML Extinction Ratio 3.5dB Media SMF Power Consumption
Features: Supports 9.95 to 11.3Gb/s bit rates Hot-Pluggable Duplex LC connector 1550nm cooled EML transmitter, APD photo-detector SMF links up to 80km 2-wire interface for management specifications compliant with SFF 8472 digital diagnostic monitoring interface Power Supply :+3.3V Power consumption
Cisco Compatible 10G 1550nm 80KM SFP+ Optical Transceiver Item NO.:ESP5592-3LCD80 Date rate: 10G Distance: 80KM Connector: LC Place of origin: Made in China Shipping Port: ShenZhen Package type: Individual package or 10pcs/package Features 1.Hot pluggable 2. 1550nm cooled EML, APD Receiver 3.Up to 80km on 9/125um SMF 4. SFP+ MSA package with duplex LC connector 5. SFI High Speed Electrical Interface 6.Very low EMI and excellent ESD protection 7. +3.3V single power supply 8. Case temperature range: -5â?? to 70â??. 9. 2-wire interface for management and diagnostic monitor 10. 10Gb/s serial optical interface compliant to 802.3ae 10GBASE-ZR/ZW 11. Power dissipation < 1.5W Applications 1.Gigabit Ethernet 2.Fiber Channel 3.Switch to Switch interface 4.Switched backplane applications 5.Router/Server interface 6.Other optical transmission systems
New SFP 2.5G Bidi 80KM Optical Transceiver Cisco HUAWEI compatibility Specification Data rate: 2.5G Wavelength: 1490/1550nm Distance: 80KM Interface: LC DDM: Yes Place of origin: Made in China Port:Shenzhen Working temperature: Commercial: 0°C to +70°C;Industrial:-40°C to +85°C Optical module used in Ethernet, SDH, Sonet,Can be compatible with CISCO 2900 Series,CISCO 4000 Series, CISCO 5000 Series,HUAWEI, the pole into, D-Link, ZTE, HP, juniper and other equipment. Our products require strict testing standards,standard packing form,to provide customers with quality service and timely delivery cycle. Scope of application: switch, Ethernet, data center, SDH, SONET, ATM Package type: Individual package or 10pcs/package