http://www.xlpecable.com/zmscable/cable_119_1.html
http://www.xlpecable.com/zmscable/abc_273_1.html
http://www.xlpecable.com/zmscable/abc_274_1.html
http://www.vericable.com/cables/rubber-cable/97.htm
0.6/1kV XLPE Insulated Cable
KVV PVC Insulation Control Cable
0.6/1kV XLPE Insulated Cable
0.6/1kV XLPE Insulated Cable
0.6/1kV XLPE Insulated Cable
PVC Insulation Electric Wire
XLPE PVC Electric Power Cable
6.35/11kV XLPE Cable
0.6/1kV XLPE Insulated Cable
0.6/1kV XLPE Insulated Cable
Standard:itu-t g.650 / itu-t g.652; itu-t g.653 / itu-t g.655; iec 60793 aluminum-clad steel wire iec 61232 / astm b 415 aluminum alloy wire iec 60104 / astm b 398 complete opgw iec 61089 / iec 60794; iec 60794-4; astm b 416 / ieee 1138 Capacity:50000 coils/week Construction options:single or double armor layers, Right or left-hand stranding lays (on single armor) Fiber count:up to 48 fibers in buffer tubes Fiber types:single-mode, corning optical fiber Aluminum-clad stainless steel core tube High crush resistance in a small form-factor Superior corrosion resistance Dissimilar metals are prevented from reacting with one another Provides performance similar to stainless steel central tube, without the risk of galvanic corrosion Meets ieee construction guidelines for use in high corrosion sites Enhanced electrical performance Use of aluminum alloy wires can be decreased Replacement with acs wires improves lightning resistance Compact design Reduced weight Increased flexibility Smaller minimum bend radius Easier to handle and install Lower wind and ice loads put less load on structures Our opgw provides a compact design without sacrificing corrosion resistance. It is best suited to applications with moderate to low span and electrical requirements.
1.9/3.3kv xlpe cable.
3.8/6.6kV XLPE Cable.
Standard:bt cw1128/1198 Capacity:50000 coils/week The steel tape armor provides increased mechanical protection and gopher resistance Conductors:solid annealed copper Insulation:dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color-coded in accordance with telephone industry standards Twisted pairs:insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk core assembly: 25 pairs and less; pairs are assembled together in a single group More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder 1200 pairs and larger are mirror image color code. Filling compound: the entire core assembly is completely filled with etpr compound , filling the interstices between the pairs and under the core tape core wrap: dielectric tape applied longitudinally with an overlap shield: corrugated, copolymer-coated, 0.008â??â?? al tape applied longitudinally with an overlap Jacket: black, linear low density polyethylene
Standard:astm b230, b231, b400 Voltage:450/750v, 600/1000v Capacity:2000km/month 1.Conductor Bare soft copper class b or class c concentrically stranded 2.Insulation Xlpe or pvc, colored for identification 3.Assembly Individual conductors are cabled, with non-hygroscopic fillers where necessary, to form a round compact core and wrapped with a binder. Two conductor versions are assembled flat parallel. 4.Shield Aluminum or copper wire, tape or braid 5.Sheath Black pvc Low-capacitance Single, pair and multiple conductor available Color-coded conductors for easy identification Durable, flexible, all-weather jacket Available at 600v for general purpose and 1000v for heavy duty We heavy duty control cables are particularly suited for substation control functions, and can also be used for general purpose control circuits in industrial applications.