As Per Client Requirements
Product Name: Tubing Encapsulated Cable Application: Monitor the temperature,pressure and other parameters in every wells. Tube Materials: 316L,Alloy 400,Alloy 825,Alloy 625. OD of Tube: 1/8'',1/4'',1/2'',3/8'',3/4'',5/8''. Wall Thickness: 0.028'',0.035'',0.049'',0.065'',0.083''. Encapsulation: Bare,Round,Square,Color-coated,Flatpacked. Sample Parameters A: 18AWG SINGLE CONDUCTOR STAINLESS STEEL TUBE SQUARE ENCAPSULATION 15,000 PSI SYSTEM INSULATION: PFA INSULATION JACKET: PFA MATERIAL TUBE: 1/4" x 0.028" A316L STAINLESS STEEL ENCAPSULATION: TPR,11mm Round A. 18#AWG 7/0.39mm Tin Coated Copper: OD 1.16mm (0.046) Nominal B. PFA INSULATION:OD 2.49mm (0.098) Nominal C. PFA JACKET: OD 4.92mm (0.194) Nominal D. 316L STAINLESS STEEL TUBE:WALL THICKNESS:0.71mm(0.028),OD 6.35mm(0.250) Nominal E. TPR ENCAPSULATION:MAJOR*MINOR:11mm*11mm Sample Parameters B: 18AWG MONOCONDUCTOR STAINLESS STEEL TUBE ENCAPSULATION 10,000 PSI SYSTEM INSULATION: ETFE INSULATION JACKET: POLYPROPYLENE MATERIAL TUBE: 1/4" x 0.028" A316L STAINLESS STEEL TUBE ENCAPSULATION: POLYPROPYLENE MATERIAL A. 18#AWG 7Ã?0.39mm Copper conductor: OD 1.19mm Nominal B. ETFE INSULATION:OD 2.60mm Nominal C. POLYPROPYLENE JACKET: OD 4.92mm Nominal D. 316L STAINLESS STEEL TUBE:WALL THICKNESS:0.71mm(0.028),OD 6.35mm(0.250) Nominal E. POLYPROPYLENE ENCAPSULATION:11mmÃ?11mm COLOR:YELLOW
Product Name: 16AWG Conductor, 316L SST Tubing Encapsulated Cable Conductor: 16AWG Solid Bare Copper Conductor, OD: 1.29mm Insulation: FEP Insulation, T-01, OD: 2.60mm Jacket: PP Jacket, P-06, OD: 4.92mm Tubing: 316L Stainless Steel Tube with 0.71mm Wall Thickness Encapsulation: PP Encapsulation, 11mm Square Shape. Working Pressure: 15000 psi Packing: 15000FT per spool or 5000m per spool
Product Name: Tubing Encapsulated Cable / Downhole Sensor Cable Application: Monitor the temperature,pressure and other parameters in every wells. Tube Materials: 316L, Duplex 2205, Incoloy825 (Alloy 825) OD of Tube: 1/8'',1/4'',1/2'',3/8'',3/4'',5/8''. Wall Thickness: 0.028'',0.035'',0.049'',0.065'',0.083''. Encapsulation: Bare,Round,Square,Color-coated,Flat packed.
Product Name: Teck90 Cable Standards: CSA FT1 & FT4,CSA C22.2 No.131 & 174,IEEE 383 &1202,ICEA T-30-520,CSA C68.3,ICEA T-29-520 Voltage: 1KV,5KV,8KV,15KV,25KV,28KV,35KV AWG Size:14,12,10,8,6,4,3,2,1,1/0,2/0,3/0,4/0,250,300,350,400,500,600,750,1000 Type: Single Conductor 1000V TECK90 Cable XLPE/PVC/AIA/PVC Two Conductor 1000V TECK90 Cable XLPE/PVC/AIA/PVC Three Conductor 1000V TECK90 Cable XLPE/PVC/AIA/PVC Four Conductor 1000V TECK90 Cable XLPE/PVC/AIA/PVC Shielded Single Conductor 90 MIL 100%/133% 5KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 90 MIL 100%/133% 5KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Single Conductor 115 MIL 133% 5KV(100% 8KV) TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 115 MIL 133% 5KV(100% 8KV) TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 140 MIL 133% 8KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Single Conductor 220 MIL 133% 15KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 220 MIL 133% 15KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Single Conductor 320 MIL 133% 25KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 320 MIL 133% 25KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Single Conductor 345 MIL 133% 28KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 345 MIL 133% 28KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Single Conductor 345 MIL 100% 35KV TECK90 Cable TR-XLPE/PVC/AIA/PVC Shielded Three Conductor 345 MIL 100% 35KV TECK90 Cable TR-XLPE/PVC/AIA/PVC
Our coiled tubing reduce the risk of leakage of the instrument hydraulics. By reducing the number of joints in the system, the installation is more convenient, especially for vertically installed industrial and mining, the advantages are more obvious. The coiled tubing improves the integrity of the entire system and reduces the risk of leakage, greatly reducing maintenance costs. Our coiled tubes can be used as oil and gas downhole control lines, chemical injection lines, instrumentation lines, electric mixing lines or steam heating lines, pre-insulation lines, flue gas pipes, heater coils, etc. Material: 316L, 316, 304, ncoloy825, incoloy625, carbon steel etc. Wall Thickness: 0.5mm3mm Length: 100M5000M Pressure Bearing: 50MPA130MPA OD: 3mm-60mm
Product Name: Tubing Encapsulated Cable, Downhole senser cable Application: Monitor the temperature,pressure and other parameters in every wells. Tube Materials: 316L, Duplex2205, Alloy 825 OD of Tube: 1/8'',1/4'',1/2'',3/8'',3/4'',5/8''. Wall Thickness: 0.028'',0.035'',0.049'',0.065'',0.083''. Encapsulation: Bare,Round,Square,Color-coated,Flatpacked.
Product Name: Tubing Encapsulated Cable / Downhole Sensor Cable Application: Monitor the temperature,pressure and other parameters in every wells. Tube Materials: 316L, Duplex 2205, Incoloy825 (Alloy 825) OD of Tube: 1/8'',1/4'',1/2'',3/8'',3/4'',5/8''. Wall Thickness: 0.028'',0.035'',0.049'',0.065'',0.083''. Encapsulation: Bare,Round,Square,Color-coated,Flat packed.
PTC Alloy wire has medium resistivity and high positive temperature coefficient of resistance. It is widely used in various heaters. It can automatically control temperature and adjust power by keeping comstant current and limiting current. GRADE:P-4500,P-4000,P-3800,P-3500,P-3000,P-2500
PTC Alloy wire has medium resistivity and high positive temperature coefficient of resistance. It is widely used in various heaters. It can automatically control temperature and adjust power by keeping comstant current and limiting current. GRADE:P-4500,P-4000,P-3800,P-3500,P-3000,P-2500
The Nickel-Chrome and Nickel-Chrome-Iron alloy wires are widely used as the high resistance alloy for electrical heating and wire-wound resistors in metallurgical industry,chemical industry and electrical industry, etc. This alloy wire has higher electrical resistance coefficient, good anti-oxidation and anti-corrosion performance, and it also has good mechanical workability and weldability, with a high strength at high temperature.
PTC Alloy wire has medium resistivity and high positive temperature coefficient of resistance. It is widely used in various heaters. It can automatically control temperature and adjust power by keeping comstant current and limiting current. GRADE:P-4500,P-4000,P-3800,P-3500,P-3000,P-2500
PTC Alloy wire has medium resistivity and high positive temperature coefficient of resistance. It is widely used in various heaters. It can automatically control temperature and adjust power by keeping comstant current and limiting current. GRADE:P-4500,P-4000,P-3800,P-3500,P-3000,P-2500
Copper nickel alloy,which has low electric resistance,good heat-resistant and corrosion-resistant, easy to be processed and lead welded.It is used to make the key components in the thermal overload relay,low resistance thermal circuit breaker, and the electrical appliances.It is also an important material for electrical heating cable.It's similar as s type cupronickel.
AS PER CLIENT REQUIREMENTS
AS PER CLIENT REQUIREMENTS
AS PER CLIENTS REQUIREMENTS
AS PER CLIENTS REQUIREMENTS
AS PER CLIENTS REQUIREMENTS
PTC Alloy wire has medium resistivity and high positive temperature coefficient of resistance. It is widely used in various heaters. It can automatically control temperature and adjust power by keeping comstant current and limiting current. GRADE:P-4500,P-4000,P-3800,P-3500,P-3000,P-2500