Hardware products, DC contactors, relay products, new energy electronics, medical devices, auto parts, motors and other industries.Development, design, manufacturing, export, service, technical training
3000W Power Station
Model number PB-D04A
Battery type LiFePO4
Nominal voltage 25.6V
Battery capacity 120Ah/3072Wh
Cycle life 3000 times
BMS Over charge, over discharge, over current, short circuit and temperature protection
Input
Anderson Fast Charge (Adapter &PV) 29.2V 20A default;29.2V,50A Max
PV Charge 20V-60V,1440W Max
Charging Temperature 0-45
Automatic Constant Feed Speed Control: Automatic output voltage adjustment in real-time to ensure constant preset feed speed regardless of weight change of the workpieces.
Automatic Frequency Adjustment: Automatic output frequency adjustment in real-time ensures the load always works at its resonant frequency.
Automatic Resonant Frequency Search: Search out and output the resonant frequency of the load. Other related parameters are also set automatically
Counting: Count the number of the workpieces. The controller will slow down or stop when counting up to the preset value. (available on SDVC34-XLRJ)
Rs485 Communication: All parameters of the controller can be adjusted via Rs485
Automatic Switch Sensor Type Recognition: The controller can recognize and adapt to both PnP and nPn type switch sensors.
Sync Output: Sync the output waveform of the slave controller with that of the master controller to the same frequency and phase to avoid the beat effect.
Overvoltage Protection: If the input voltage is too high, the power supply of the controller will be shut down automatically to protect itself.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the controller's output is short-circuited, it will shut down its production to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side the controller will work again after power is on.
Automatic Constant Feed Speed Control: Automatic output voltage adjustment in real time to ensure constant preset feed speed regardless of weight change of the workpieces.
Automatic Frequency Adjustment: Automatic output frequency adjustment in real time to make sure the load is always working at its resonant frequency.
Automatic Resonant Frequency Search: Search out and output resonant frequency of the load. other related parameters are also set automatically
Counting: Count number of the workpieces. The controller will slow down or stop when count up to preset value. (available on SDVC34MRJ)
Rs485 Communication: All parameters of the controller can be adjusted via R485.
Automatic Switch Sensor Type Recognition: The controller can recognize and adapt to both PNP and NPN type switch sensors
Sync Output: Sync output waveform of the slave controller with that of the master controller to the same frequency and phase to avoid beat effect
Overvoltage Protection: If input voltage is too high, power supply of the controller will be shutdown automatically to protect itself.
Digital Overheat Protection: If internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If output current exceeds its rated value he controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power on.
Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect.
Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation.
Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset.
Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off.
Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn the controller on/off.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices.
Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
Wistek 12V 100Ah Max LiFePO4 Lithium Deep Cycle Battery adopts 2C rate EVE Grade A cells with durable aluminum casing. It contains no toxins and can charge over 4000 times at 100% DOD for over a 10-year lifespan. Withstanding Max 2560W Power and can support a maximum 2C rate discharging and 1C rate charging, it can be used in scenarios that require higher Power. No need to bother with the limitations of lead-acid batteries anymore! Choose Wistek without hesitation for its lighter weight, less space, higher power, and larger energy!
CE certificated, RoHS compliant.
Automatic Constant Feed Speed Control: Automatic output voltage adjustment in real-time to ensure constant preset feed speed regardless of weight change of the workpieces.
Automatic Frequency Adjustment: Automatic output frequency adjustment in real-time to make sure the load is always working at its resonant frequency.
Automatic Resonant Frequency Search: Search out and output the resonant frequency of the load. other related parameters are also set automatically
Counting: Count the number of the workpieces. The controller will slow down or stop when counting up to the preset value. (available on SDVC34MRJ)
Rs485 Communication: All parameters of the controller can be adjusted via R485.
Automatic Switch Sensor Type Recognition: The controller can recognize and adapt to both PNP and NPN-type switch sensors
Sync Output: Sync the output waveform of the slave controller with that of the master controller to the same frequency and phase to avoid the beat effect
Overvoltage Protection: If the input voltage is too high, the power supply of the controller will be shut down automatically to protect itself.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If output current exceeds its rated value the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect.
Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation.
Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset.
Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off.
Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn the controller on/off.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices.
Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect.
Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation.
Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset.
Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off.
Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn the controller on/off.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices.
Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect.
Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation.
Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset.
Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off.
Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices.
Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
Automatic Constant Feed Speed Control: Automatic output voltage adjustment in real-time to ensure constant preset feed speed regardless of weight change of the workpieces.
Automatic Resonant Frequency Search: Search out and output the resonant frequency of the load. other related parameters are also set automatically
Rs485 Communication: All parameters of the controller can be adjusted via R485.
Sync Output: Sync the output waveform of the slave controller with that of the master controller to the same frequency and phase to avoid beat effect
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If output current exceeds its rated value the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the controller's output is short-circuited, it will shut down its production to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Frequency Adjustment: The output frequency of the controller can be manually adjusted to the resonant frequency of the vibratory feeder to get smooth, quiet, and energy
saving feed effect
Automatic High Precision Voltage Requlation: The internal digital voltage regulation circuit can eliminate feed sped variation caused by mains voltage fluctuation.
Time Adjustable Soft Start: The controller will increase output voltage from 0 to the preset value when powered on to avoid a sudden shake. soft start time can be
digitally preset
Switch Sensor ON/OFF Control NPN switch sensor or PLc can be connected to turn on/off the controller.
Photoelectric Sensor ON/OFF Control: The cuH inteligent Photoelectric sensor can be connected to turn on/off the controller.Remote speed Control. The output voltage of the controller can be adjusted remotely by an external potentiometer, a Plc, or a 1-5v DC signal.
DC Control Output: The controller can output low voltage DC power asociated with ON/0ff Control of the controller to drive a solenoid or other external devices.Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/Off button and hold
Frequency Adjustment: The output frequency of the controller can be manually adjusted to the resonant frequency of the vibratory feeder to get a smooth, quiet, and energy-saving feed effect.
Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation.
Time Adjustable Soft Start: The controller will gently increase output voltage from 0 to the preset value when powered on to avoid sudden shaking. Soft start time can be digitally preset.
Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn on/off the controller.
Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller.
Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices.
Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds.
Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself.
Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load.
Restorable Short Circuit Protection: If the controller's output is short-circuited, the controller will shut down its production to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.
Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by a voltage that is too high.
MPN
J75X020, RVE-Y1
Bagged/Bagless
Bagless
Smart Home Compatibility
Amazon Alexa
Brand
iRobot
Runtime
75 min
Filters
HEPA
Type
Robotic
Charge Time
3 hrs
Capacity
0.4 L
Model
Roomba j7
Included Accessories
Filter
Features
Battery Operated, Edge Cleaning, Multi Surface, Removable Brushroll, Rinsable Filter, Rotating Brushes, Factory Sealed, Automatic Dirt Disposal
Cord Type
Cordless
Smart Home Protocol
Wi-Fi
Power
33 W