Model: 32V 1000mA for HP 0957-2176 Output: 32V 1000mA Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Size: 15X15X6 cm (L x W x H) Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment Test: Temperature test; Vibration test; Drop-Test; Overcharging and discharging test Line Regulation: +/-5% Load Regulation +/-5%
Model: 32V 250mA for HP Deskjet 3300 3400 Seriesï¼?HP Deskjet 3320, 3320v, 3322, 3420, 3420v, 3425, 3450 Output: 32V 250mA Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Size: 15X15X6 cm (L x W x H) Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment Test: Temperature test; Vibration test; Drop-Test; Overcharging and discharging test Line Regulation: +/-5% Load Regulation +/-5%
Model: 29V 2A AC DC Switching Power Supply Transformer for Lazy Boy Lift Chair, Hmleaf Recliner Lift Chair, Okin Limos Tranquil Ease Lift Chair, Okin Electric Recliner BetaDrive Motors Sofa Output: 29V 2A Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Size: 15X15X6 cm (L x W x H) Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment Test: Temperature test; Vibration test; Drop-Test; Overcharging and discharging test Line Regulation: +/-5% Load Regulation +/-5%
Model: 19.5V 7.7A 180W 7.4/5.0mm Output: 19.5V 7.7A Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment
Model: 24V 10A AC-DC Switching Power Supply 240W Output: 24V 10A Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment
Model: AC 100-240V To DC 12V 20A Power Supply 240W Output: 12V 20A Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment
Model: Ac Power Supply 24V 5A 120W 4Pin LCD LED Lamp Output: 24V 5A Power cord: UK US EU AU Power Cord Outlet: 2/3 prong Packing: Brown box with pe bag and bubble bag; 49*39*34CM(L x W x H) for a master carton size Delivery Date: Within 2-3 working days after confirming the payment
"FAMAGA Group OHG, the global supplier of industrial equipment and spare parts, is glad to provide encoders by I/O Modules Kieback & Peter: We supply a complete range of the manufacturerâ??s catalog, including the following items: Kieback & Peter DDC420 Kieback & Peter FBU410 Kieback & Peter TLD2 Kieback & Peter FBM018 Kieback & Peter TVD1 Kieback & Peter FW113H5 Kieback & Peter MD200Y Kieback & Peter Z201 Kieback & Peter TAD Our company is also pleased to offer products of other brands: Bei Sensors IBH Softec Schmersal BALLUFF Pepperl+Fuchs Bernstein Di-Soric Elobau Univer Eltra Aventics FESTO Camozzi Euchner END-Armaturen TAMAGAWA SENECA Airtac Murrelektronik Azbil Yamatake FRANKE-Filter Endress+Hauser IFM Ipf Electronic Kieback & Peter MD Micro Detectors Bihl Wiedemann ANDERSON-NEGELE KITAGAWA Georg Schlegel Metal Work Kipp Allen-Bradley Netter Vibration Kuebler / K�¼bler RAFI LINDY 4B Braime SOUTHCO ELGO Electronic FAG RECO Pilz AIRTEC Pneumatic COMITRONIC-BTI L�¼tze Hydac Barksdale Keyence AirCom Pneumatic Garlock Mac Valves MAHLE (Filtration Group) Riegler Baumer Elreha Sick Siko FAMAGA Group OHG is a family-owned company with many years of experience in the supply of components and spare parts for industrial enterprises around the world. Our mission is to provide fair prices, reducing the cost of production for our customers. A significant network of suppliers around the world allows us to supply any equipment, which client needs on favorable terms. Therefore, the list of equipment we provide is tenfold greater than the catalog presented on this site. You are welcome to check the full catalog on our website."
"FAMAGA Group OHG, the global supplier of industrial equipment and spare parts, is glad to provide encoders by Power Supplies Pepperl+Fuchs: We supply a complete range of the manufacturerâ??s catalog, including the following items: Pepperl+Fuchs F2D0-FB-EX4.CGS Pepperl+Fuchs 132960 Pepperl+Fuchs 231364 Pepperl+Fuchs 248764 Pepperl+Fuchs 132958 Pepperl+Fuchs 231194 Pepperl+Fuchs KFD2-UT2-Ex2 Pepperl+Fuchs KFD2-STC4-EX2 Pepperl+Fuchs UC2000-30GM-IUR2-V15 Pepperl+Fuchs 106437 Pepperl+Fuchs 46904 Pepperl+Fuchs 102157 Pepperl+Fuchs 190653 Pepperl+Fuchs 194775 Pepperl+Fuchs 231193 Pepperl+Fuchs 248767 Pepperl+Fuchs 71816 Pepperl+Fuchs KFD2-EB2 Pepperl+Fuchs KFD2-UT2-EX1 Our company is also pleased to offer products of other brands: Bei Sensors IBH Softec Schmersal BALLUFF Pepperl+Fuchs Bernstein Di-Soric Elobau Univer Eltra Aventics FESTO Camozzi Euchner END-Armaturen TAMAGAWA SENECA Airtac Murrelektronik Azbil Yamatake FRANKE-Filter Endress+Hauser IFM Ipf Electronic Kieback & Peter MD Micro Detectors Bihl Wiedemann ANDERSON-NEGELE KITAGAWA Georg Schlegel Metal Work Kipp Allen-Bradley Netter Vibration Kuebler / K�¼bler RAFI LINDY 4B Braime SOUTHCO ELGO Electronic FAG RECO Pilz AIRTEC Pneumatic COMITRONIC-BTI L�¼tze Hydac Barksdale Keyence AirCom Pneumatic Garlock Mac Valves MAHLE (Filtration Group) Riegler Baumer Elreha Sick Siko FAMAGA Group OHG is a family-owned company with many years of experience in the supply of components and spare parts for industrial enterprises around the world. Our mission is to provide fair prices, reducing the cost of production for our customers. A significant network of suppliers around the world allows us to supply any equipment, which client needs on favorable terms. Therefore, the list of equipment we provide is tenfold greater than the catalog presented on this site. You are welcome to check the full catalog on our website."
Per requirements. Per requirements
22000+ qty laptop batteries the battery life will be 85-90%
I have a Ge 19,700 kw generator and turbine for sale .
This test bench can be widely used in measurement centers of start grid, management and electric energy measuring departments of power supply companies, national measurement laboratories, as well as large industrial and mining enterprises and electric meter manufacturers.
HS-3303M is a three-phase electric energy meter inspection device designed based on the requirements of the IR46 metering part, which meets the harmonic requirements of the IR46 electric energy meter. It can output square wave, peak wave, current multiple zero-crossing wave, higher harmonics, odd harmonics, sub-harmonics, custom harmonics, etc. This device is equipped with 3 epitopes and has a small structure, which is suitable for product research and development, model selection, random inspection, etc. For more product details,please see Energy Meter Test Bench this page :
qt - 800 pcs fob - california conditioin-new braND - artesyn model- DS1100PED-3-A
Transformers, generators, large and small gas and furnace oil turbines, lighting system equipment and supplies, lightning and grounding systems or power plants, switch yards and substations, electrical rooms and battery systems.
CE certificated, RoHS compliant. Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect. Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation. Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset. Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off. Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn the controller on/off. Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal. DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices. Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds. Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself. Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load. Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on. Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
CE certificated, RoHS compliant. Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect. Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation. Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset. Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off. Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn the controller on/off. Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal. DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices. Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds. Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself. Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load. Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on. Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
CE certificated, RoHS compliant. Frequency Adjustment: The controller's output frequency can be manually adjusted to the vibratory feeder's resonant frequency to achieve a smooth, quiet, and energy-saving feed effect. Automatic High Precision Voltage Regulation: The internal digital voltage regulation circuit can eliminate feed speed variation caused by mains voltage fluctuation. Time Adjustable Soft Start: When powered on, the controller will gently increase output voltage from 0 to the preset value to avoid a sudden shake. The soft start time can be digitally preset. Switch Sensor ON/OFF Control NPN switch sensor or PLC can be connected to turn the controller on/off. Photoelectric Sensor ON/OFF Control: The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller. Remote Speed Control: Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal. DC Control Output: The controller can output low voltage DC power associated with the ON/OFF Control of the controller to drive a solenoid or other external devices. Keypad Lock: Lock all buttons on the keypad to prevent misoperation by pressing the ON/OFF button and holding for 2 seconds. Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself. Overcurrent Protection: If the output current exceeds its rated value, the controller will stop its output to protect itself and the load. Restorable Short Circuit Protection: If the output of the controller is short-circuited, the controller will shut down its output to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on. Max Adjustable Output Voltage: Max Adjustable Output Voltage can be preset to protect the load from damage caused by too high voltage.
Automatic Constant Feed Speed Control: Automatic output voltage adjustment in real-time to ensure constant preset feed speed regardless of weight change of the workpieces. Automatic Resonant Frequency Search: Search out and output the resonant frequency of the load. other related parameters are also set automatically Rs485 Communication: All parameters of the controller can be adjusted via R485. Sync Output: Sync the output waveform of the slave controller with that of the master controller to the same frequency and phase to avoid beat effect Digital Overheat Protection: If the internal temperature of the controller gets too high, the controller will stop its output to protect itself. Overcurrent Protection: If output current exceeds its rated value the controller will stop its output to protect itself and the load. Restorable Short Circuit Protection: If the controller's output is short-circuited, it will shut down its production to protect itself and the load. But the fuse inside will not be blown. So when there is no short circuit at the output side, the controller will work again after power is on.