Please click here to check who's online and chat with them.

Find Verified Medical Equipment Machinery Suppliers, Manufacturers and Wholesalers

Oct-22-20

T4

$0
MOQ: Not Specified
 
Thyroid Function 10-320 ng/ml Serum/Plasm 15Min.
Oct-22-20

Tsh

$0
MOQ: Not Specified
 
Thyroid Function 0.05-80IU/ml Serum/Plasma/Whole blood 15Min.
Apr-29-20
 
Ventilator YH-830 bi-level PAP device
CE certification and FDA certificate
FOB Price USD 6.100/ Set
Stock 300 units in stock today
Payment term: T/T in advance.
Delivery immediately after payment

Technical parameters of YH-830 bi-level PAP device
1. Scope of application:
For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive
ventilation in a hospital or home.

2. the main function:
1. Different treatment options can be provided according to patients' needs, from CPAP
to S, T, S / T, VGPS five modes
2. Adjustable trigger sensitivity.
3. Real-time monitoring and recording of blood oxygen saturation.
4. alarm function.
5. Record function (SD card).
6. Maximum leak compensation function. 60L/min
7. With trolley, easy to move in the hospital

3. the key technical parameters:
1. Working mode: CPAP, S, T, ST, VGPS.
2. Ventilation parameters:
2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval)
2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval)
2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval)
2.4 Delayed boost: 0-45 minutes (interval of 5 minutes)
2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute)
2.6 Breathing ratio: 10-70% (interval of 1%)
2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly)
2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st
step triggers slowest)
2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the
slowest)
2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml)
3.VGPSï¼?same with AVAPS, can set Target tidal volumeï¼?
3.1 Maximum IPAP value adjustable range: 4-30 cmH2O
3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O
3.3 EPAP value adjustable range: 4-30 cmH2O
3.4 Target Tidal Volume: 50-1500ml

4. Display range of monitoring setting parameters:
4.1 Respiratory waveform can be displayed;
4.2 Current mode: CPAP, S, T, ST, VGPS
4.3 Inspiratory pressure: 4-30 cmH2O
4.4 Expiratory pressure: 4-30 cmH2O
4.5 Breathing frequency: 5-50 times / minute
4.6 Breathing ratio: 10-70%
4.7 Air leakage: 20-99.9lpm
4.8 Tidal volume: 50-1500ml
4.9 minute ventilation: 0-50lpm
4.10 Blood oxygen saturation: 70-100%
4.11 Pulse rate: 25-250bpm
4.12 Delay boost: 0-45 minutes

6.Specifications
6.1 Weight: about 20kg including the trolley and the device
6.2 Operating temperature: 5-35 C
6.3 Relative humidity: 10% -90%
6.4 Power supply: input is AC 100-240V, 50-60Hz, 1.8A Max; output: DC 24V, 3.33A.
Feb-26-19
Supplier From Essex, United Kingdom
Jul-13-23
Supplier From London, London, United Kingdom
 
Laryngoscopes
581 Medical Equipment Machinery Suppliers
Short on time? Let Medical Equipment Machinery sellers contact you.
Jul-13-23
Supplier From London, London, United Kingdom
 
Perforator 01
Nov-29-21
Supplier From Oxford, United Kingdom
Apr-12-20
Supplier From London, United Kingdom
Apr-01-20
Supplier From United Kingdom, United Kingdom
Sep-27-18
Supplier From London, United Kingdom
Mar-25-08
Supplier From Leicester, United Kingdom
Dec-16-15
Supplier From London, United Kingdom
Apr-13-23
Supplier From United Kingdom
Oct-20-19
Supplier From London, Middlesex, United Kingdom
Dec-22-06
Supplier From London, United Kingdom
Mar-30-07
Supplier From Leicester, United Kingdom
Oct-24-21
Supplier From London, United Kingdom
Jul-13-15
Supplier From London, Surrey, United Kingdom
Nov-01-18
Supplier From Kent, United Kingdom
Nov-11-22
581 Medical Equipment Machinery Suppliers
Short on time? Let Medical Equipment Machinery sellers contact you.
See what buyers and suppliers are discussing in Medical Equipment Machinery import export community