Lightbars, siren announcement systems, warning lighting systems, strobes.
Primary Knee System Arthroplasty
CORAIL Total Hip System Primary Knee System TOTAL INSTRUMENT SET SYSTEM
We have the ja1 & en59010ppm product available in Rotterdam. Our company regulates oil contracts between the seller and the buyer well and reserves all the rights of the intermediaries and both parties (the seller and the buyer). We have most petroleum products available (en59010ppm & ja1) for those interested in the subject and serious buyers only, we offer our services. 100,000 metric tons of EN590 10 PPM material at the Rotterdam Port. price $735 per ton. $10 for brokers ($5 from seller side $5 from buyer side) 2,000,000 barrel JA1 Fuel at the Rotterdam Port price 92$ per barrel . $10 for brokers ($1 from the seller's side and $1 from the buyer's side). The deal will be subject to the following procedures: PROCEDURES (Tank to Tank ) JA1& EN590 10PPM. 1. Buyer issue ICPO, (TSA), Financial Capability, 2. Banking details, scanned copy of buyer's passport along with CP and Reg. Certificate. 3. Seller issues commercial invoice to be signed by Buyer and Seller. 4. Seller issue to Buyer the Dip Test Authorization document (DTA) which is to be signed by the Buyer, Seller, and Buyerâ??s logistic company as verification. 5. Seller issues the PPOP listed below to the Buyer: TSR with GPS coordinates of the Tank Location. Injection report. Certificate of Origin. Authorization to sell. SGS report. Product Passport (Lab Analysis Report). 6. Buyer Conducts Dip Test and sends TSR to Seller. 7. Upon successful Dip Test in Sellers Tanks, product will immediately be injected into Buyer's Tanks. Buyer makes payment for the product via MT103/TT." If these procedures and price suit the buyer's requirements, you can contact us.
100,000 metric tons of EN590 10 PPM material at the Port of Rotterdam price is $735 per ton. The transaction will be subject to the following procedures: Procedures (tank to tank) FOB Rotterdam standard procedures: 1. Buyer issues ICPO, (TSA), financial capacity, 2. Bank details, scanned copy of buyer's passport along with CP and Reg. certificate. 3. The seller issues a commercial invoice signed by the seller and buyer. 4. The Seller issues to the Buyer a Dipping Test Authorization (DTA) document which must be signed by the Buyer, the Seller and the Buyer's logistics company as verification. 5. Seller issues the PPOP listed below to Buyer: â?? TSR with GPS coordinates of tank location. â?? Injection report. â?? Certificate of origin. â?? Permit to sell. â?? SGS report. â?? Product passport (laboratory analysis report). 6. Buyer conducts dip test and sends TSR to seller. 7. After successful dipping test in sellers' tanks, the product will be immediately injected into buyer's tanks. Buyer pays for the product via MT103/TT.
ENplus A1 quality certificate ( TR-023) TSE A1 certificate (Turkish Standard Institution) ISO 9001 ISO 14001 ISO 45001 * 1500 tonnes ready to load * Please contact via Whatsapp
Dustless Chalk Machine-Automatic Dustless Chalk Machine - Calcium Carbonate Chalk Machine - School Chalk Machine - Big Capacityy Chalk Machine
TSE EN ISO 17225-2 A1 KALITE BELGEL QUALITY CERTIFICATE % 100 MUSTERI MEMNUNIYETI % 100 CUSTOMER SATISFACTION INDIRIMLI FIYATLAR DISCOUNTED PRICES
ORTHOSYN MRY KNOTLESS ANCHOR The good knotless Anchor; They should be able to detect sutures in the bones, should not come back from the bone, facilitate the surgical technique, should not cause any problem in the post-op period, be biocompatible and allow early rehabilitation. ORTHOSYN MRY Knotless Anchor It can be use for soft tissues. The implant is made from one piece of PEEK. REF PRODUCT DESCRIPTION 16.150.018 3.5mm knotless anchor PEEK 16.150.019 4.5mm knotless anchor PEEK Arthroscopic reconstructive surgery poses many challanges for the surgeon. One of these is the tying of arthroscopic knots. To achieve reliable, reproducible knots every time requires a lot of practice and skill. Some surgeons prefer knotless devices for many reasons. Knots are extremely strong and reliable. Well tied knots are strong enough to withstand tendon and bone forces. Arthroscopic knots are the same as those used by climbers and sailors, so knot security is not a concern in the experts hands. Knots are versatile and can be used in any suture repair situation, such as margin convergence for cuff repair or with suture anchors. Possible disadvantages of knots are a theroretical risk of tissue irritation, potential postoperative joint clicking from large knots and surgeons knot-tying skill. For consistent knot-tying a surgeon must be well practiced in tying knots on models before doing so on patients. Knotless anchors have the advantage of avoiding the problems above and potentially reducing surgical time as well. Orthosyn MRY knotless anchors designed for use during arthroscopic and mini open surgery and reconstruction procedures. material: PEEK
ORTHOSYN LIGAMENT STAPLE ligament, bone or tendon fixation Full stability in the staple holder. Reinforced corners for stability. Effective anti-backout serrations. Sharp bevelled points. Used for the fixation of all anatomical or prosthetic components. Used for knee or other joints. Cobalt-chromium alloy Staples are fixed and stable in all directions. Full stability in the staple holder ensuring immediate fixation stability. Reduced risk of pain due to implant micromotion. The staples are easy to remove because they provide a firm grip to the staple extractor. sterile or non-sterile 8X20MM
Multi-Axis Tubular Fixator Radio Sulient not visible on x-ray Lightweight and durable with special alloy plastic structure Anatomical compliance with right and left fixators Compression feature Easy and quick application in sterile box
ORTHOSYN INTERFERENCE SCREW -Material: PEEK -provide strong mechanical fixation for both bone-patellar tendon-bone (BTB) and soft tissue grafts in ACL and PCL reconstruction. PEEK Interference Screws feature a thread pattern that allows for a simple surgical technique, with minimal tunnel preparation. â??PEEK With a modulus similar to cortical bone, PEEK polymer exhibits an ideal combination of strength, stiffness and toughness, together with a bio-inert nature and MRI compatibility. PEEK screw with the closest character to bone structure. It is more resistant than Biocomposite and PLLA. Bioabsorbable is easy to revise compared to the screws. The foreign substance does not react. REF PRODUCT DESCRIPTION 16.150.031 orthosyn INT screw PEEK 7x25mm 16.150.032 orthosyn INT screw PEEK 7x30mm 16.150.033 orthosyn INT screw PEEK 8x25mm 16.150.034 orthosyn INT screw PEEK 8x30mm 16.150.035 orthosyn INT screw PEEK 9x25mm 16.150.036 orthosyn INT screw PEEK 9x30mm 16.150.037 orthosyn INT screw PEEK 9x35mm 16.150.038 orthosyn INT screw PEEK 10x25mm 16.150.039 orthosyn INT screw PEEK 10x30mm 16.150.040 orthosyn INT screw PEEK 11x25mm 16.150.041 orthosyn INT screw PEEK 11x30mm INDICATION Knee: ACL repair Lateral and medial cholateral ligament reconstruction. Achilles tendon repair Lateral ST, FDL and FHL tendon repair Hand: Ligament reconstruction SCL KLR Elbow: Distal Biceps tendon repair UCL Shoulder: Proximal biceps tendon repair
Self Tapping The screw threads are designed to provide maximum retention in the cortical bone. Needle and needleless options. Special design handle for suture and needle reserve Ergonomic handle design REF PRODUCT DESCRIPTION 16.150.012 2.0mm suture anchor TI without needle 16.150.013 2.8mm suture anchor TI without needle 16.150.014 3.5mm suture anchor TI without needle 16.150.015 3.5mm suture anchor TI with needle 16.150.016 5.0mm suture anchor TI with needle 16.150.017 5.0mm suture anchor TI without needle
ORTHOSYN MTP PROSTHESIS Modular Replacement of the First Metatarsophalangeal Joint Orthosyn MTP is a modular joint replacement for the first metatarsophalangeal joint intended for use in patients with hallux rigidis or other destructive conditions of the joint. The components are modular and can be used for either hemi- or total joint replacement. The total joint includes a polyethylene articulation. Stems are titanium and uncemented; the bearing surface is cobalt chrome. Indications: Hemiarthroplasty Hallux rigidus with mild to moderate arthrosis Advanced arthrosis, with a good weight-bearing layer of suchondral bone in the head of the 1st metatarsal Post-traumatic arthrosis Salvage operation following hallux valgus operation with trimming or arthrosis Total joint replacements Hallux rigidus with moderate to severe arthrosis Pronounced post-traumatic arthrosis Rheumatoid arthritis Salvage operation in the presence of major destruction of joint proportions Revision of silicone rubber or metal joint implants REF PRODUCT DESCRIPTION 66.890.006 metatarsal head 8mm 66.890.007 metatarsal head 7mm 66.890.008 metatarsal head 6mm 66.890.210 metatarsal component S 66.890.220 metatarsal component M 66.890.230 metatarsal component L 66.890.240 metatarsal component XL 66.890.115 phalanx insert 15-5.0mm 66.890.125 phalanx insert 15-6.0mm 66.890.135 phalanx insert 15-7.5mm 66.890.145 phalanx insert 15-9.0mm 66.890.010 phalangeal component S 66.890.020 phalangeal component M 66.890.030 phalangeal component L 66.890.040 phalaheal component XL REF DORSAL FLEXION SYSTEM 66.890.300 metatarsal head DF 10mm 66.890.310 metatarsal head DF 20mm 66.890.320 metatarsal head DF 30mm 66.890.330 metatarsal head DF 40mm 66.890.340 metatarsal DF component 7.5mm 66890350 metatarsal DF component 9.5mm 66.890.360 phalanx total 10mm 66.890.370 phalanx total 20mm 66.890.380 phalanx total 30mm 66.890.390 phalanx total 40mm 66.890.400 phalangeal component 7.5mm 66.890.410 phalangeal component 9.5mm
Certofix Safety Trio Triple-lumen catheter set for catheterization of the vena cava according to the Seldinger method with the possibility of ECG based Central Venous Catheter tip placement and position control Picture of product Certofix Safety Trio Set consists of:
3 Layer Protective Mask Iir,fda And Ce Marked
ETHICON surgical stapling portfolio addresses the challenges of tissue thickness, tissue movement during firing, staple line security, and tissue tension with the objective of providing greater stapling precision in surgery. Improving outcomes with a scientific approach to stapling and evaluating the impact with evidence â?? our portfolio goes "beyond the benchtop," using real-world evidence in colorectal, bariatric and thoracic surgery.
B. Braun offers a holistic infusion therapy concept which combines high-quality products with intelligent technologies and services
ETHICON Energy Sealing and Dissecting
Vasofix Safety is a peripheral IV catheter with an injection port and a passive fully automatic needlestick protection. The single-use device is intended to generate intravascular access to sample blood, and administer fluids/medication and blood/blood products intravenously.