- Radial Flow Roof Fans -Impeller With Backward-Curved Blades Made From Sheet Metal - Accident Protection Net Around Impeller - Electric Motor With B5 Flanged - Hood For Protection Against To Atmospheric Agents.
- Axial Flow Roof Fans - Directly Coupled Motor. - Impeller Is Manufactured From Polypropylene Blade. - Hub Is Made By Cast Aluminium. - Rigid Case With Sheet Metal. - Accident Prevention Net Suction Side Of Impeller - Hood For Protection Against To Atmospheric Agents.
- In-line Rectangular Duct Fans Have Advantageous With Compact Design and Easy Installation To Duct. - Directly Coupled External Rotor Motor. - Impeller and Casing Is Manufactured From Galvanised Steel. - High Efficient Backward Curved Centrifugal Impeller. - Possibility To Easily Maintanence and Cleaning To Impeller With The Help Of A Hinged Cover.
- Axial Flow Duct Type Tubular Fans - With Belt-Driven Motor. - Impeller Is Manufactured From Cast Aluminium Blade. - Hub Is Made By Cast Aluminium. - Duct Fan With Double Flanged Cylindrical Tube Case. - Rigid Construction In Sheet Metal.
- Axial Flow Duct Type Tubular Fans - With Belt-Driven Motor. - Propoller Is Manufactured From Galvanised Steel. - Duct Fan With Double Flanged Cylindrical Tube Case. - Rigid Construction In Sheet Metal.
- Axial Flow Duct Type Tubular Fans - Directly Coupled Motor. - Impeller Is Manufactured From Cast Aluminium Blade. - Hub Is Made By Cast Aluminium. - Duct Fan With Double Flanged Cylindrical Tube Case. - Rigid Construction In Sheet Metal. - Air Flowrate : 3.150 - 96.500 m³/h (Min. - Max.) - Smoke exhaust, suction of dusty and wet air in the foundries, cement factories, paper factories and joinery works, building ventilation and for heater and refrigerators.
- Axial Flow Duct Type Tubular Fans - Directly Coupled Motor. - Impeller Is Manufactured From Polypropylene Blade. - Hub Is Made By Cast Aluminium. - Duct Fan With Double Flanged Cylindrical Tube Case. - Rigid Construction In Sheet Metal. - Air Flowrate : 3.150 - 96.500 m³/h (Min. - Max.)
- Axial Flow Duct Type Tubular Fans - Directly Coupled Motor. - Propoller Is Manufactured From Galvanised Steel. - Duct Fan With Double Flanged Cylindrical Tube Case. - Rigid Construction In Sheet Metal. - Air Flowrate : 3.000 - 67.500 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Square Framed Case Design. - Directly Coupled Motor. - Impeller Is Manufactured From Cast Aluminium Blade. - Hub Is Made By Cast Aluminium. - Rigid Construction In Sheet Metal. - Air Flowrate : 3.150 - 96.500 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Square Framed Case Design. - Directly Coupled Motor. - Impeller Is Manufactured From Polypropylene Blade. - Hub Is Made By Cast Aluminium. - Rigid Construction In Sheet Metal. - Air Flowrate : 3.150 - 96.500 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Square Framed Case Design. - Directly Coupled Motor. - Propoller Is Manufactured From Galvanised Steel. - Rigid Construction In Sheet Metal. - Air Flowrate : 3.000 - 67.500 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Square Framed Case Design. - Directly Coupled Motor. - Rigid Construction In Sheet Metal. - Air Flowrate : 2.750 - 18.000 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Directly Coupled Motor. - Impeller Is Manufactured From Cast Aluminium Blade. - Hub Is Made By Cast Aluminium. - Single Flanged Ducting Drum - Rigid Construction In Sheet Metal. - Air Flowrate : 3.150 - 96.500 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Directly Coupled Motor. - Impeller Is Manufactured From Polypropylene Blade. - Hub Is Made By Cast Aluminium. - Single Flanged Ducting Drum - Rigid Construction In Sheet Metal. - Air Flowrate : 3.150 - 96.500 m³/h (Min. - Max.)
- Axial Flow Wall/Window Type Fans - Directly Coupled Motor. - Propoller Is Manufactured From Galvanised Steel. - Single Flanged Ducting Drum - Rigid Construction In Sheet Metal. - Air Flowrate : 3.000 - 67.500 m³/h (Min. - Max.)
- Axial Flow Wall / Window Type Fans - Directly Coupled Motor. - Single Flanged Ducting Drum - Rigid Construction In Sheet Metal. - Air Flowrate : 2.750 - 18.000 m�³/h (Min. - Max.) - Smoke exhaust, suction of dusty and wet air in the foundries, cement factories, paper factories and joinery works, building ventilation and for heater and refrigerators.
- Belt-driven Motor. - Medium Pressure Radial Fan. - Backward-Curved (BC) Blade Fans. - Rigid Construction In Sheet Metal. - Statically and Dynamically Balanced Impellers. - On Demand, Special Stainless Steel Manufacturing Is Available
- Belt-driven Motor. - Low Pressure Radial Fan. - Backward-Curved (BC) blade fans. - Rigid Construction In Sheet Metal. - Statically and Dynamically Balanced Impellers. - On Demand, Special Stainless Steel Manufacturing Is Available.
- High Pressure Radial Fan. - Directly Coupled Motor. - Air Blower with Radial-Bladed Impeller. - Revolvable Fan Case. - Air Flowrate : 450 2.000 m�³/h (Min. Max.) - Pressure (Pt) : 250 - 1.000 mmss (Min. - Max.) - Gas boosting, combustion air, air flotation systems, aeration of waste water, molten iron, and other fluids, pneumatic conveying of agricultural grains (corn, oats, barley, wheat, rice) and other materials.
- Low Pressure Mini Radial Fan. - Directly Coupled Motor. - Forward-Curved (FC) Blade Fans. - Revolvable Fan Case. - Coupled With 2-Poles (3000rpm) Motors. - Air Flowrate : 1.950 - 8.500 m�³/h (Min. - Max.) - Pressure (Pt) : 90 - 300 mmss (Min. - Max.) - On Demand, Special Stainless Steel Manufacturing Is Available