This device is used for impel dry products from full pallets which are going to machine from tail collector one by one. This robot is labor saver system, you dont have to hire extra staff for dry product collecting. By using collector robot you can also decrease forklift costs in drying area. Hyrdaulic power is supplied by seperated hydraulic unit or, machines hydraulic system. Front and back motions of the jaw is regulated by motor-reducer. Frame of the collector robot construction will be designed according to machine dimensions, and for long life usage.
Led lighting manufacturer, street lightings, industrial lighting, outdoor lightings, indoor lightings, decorative lightings, landscape lightings, facade lightings, smart lightings,.Transportation, agent, shipment
Laser cut steel products, press brake steel products.Steel production, selling and shipping.
Built in ovens, freestanding ovens, mini ovens, microwaves, built-in hobs, countertop hobs, range hoods, heaters, coolers.
Furniture, Chairs, Home Appliances .
Fin tube heat exchangers, air cooled condensers, cold room evaporators, dry coolers, air conditioning system batteries and all kinds of customer oriented (oem) dx cw and condenser batters..
Lighting product, connectors,fiber optic , network , connectors, overmold cable assemblies, cable assemblies, cable assemblies, uvc, ear protector, rapid test kit, nucleic acid test box for testing covid 19,test kits,antibody test kits,cables,street lights,solar led street lights,uv lamp,street lamp,coaxial cables,telecommunication cables.
JCBENERGY engine  JCBENERGY alternator Soundproof  50 / 60 HZ 127 / 220V, 230 / 400V, 277 /480V jcbenergy GENERATOR MANUFACTURER
Robotic Gloves
Charging Vending Machines for Service Businesses These devices provide extra income by using them in places where customers spend time. The customer inserts the coin and charges his phone at the specified charging time. It saves from cable crowds and electricity bills; increases customer satisfaction, increases the consumption of customers by spending more time in the restaurant. -The device can be produced in the requiered coin(usd,eur,.....etc). -It has a charging time of 300 minutes. -With Li-ion battery, it supports ios, type-c and android in fast charging. -The coin amount and charging time can be adjusted from the digital display. -It has a very solid stainless steel case and a coin lock mechanism. -There is a smart balance counter system with reset, you do not have to count coins. - It is very easy to use and maintain. -All language options are available. Color options, brands and all options can be provided for high volume purchases at the dealership for cities. -It has charging stands that can charge without contact, it reaches 0% to 100% charge in a total of 3 hours. -You can supply as 3, 5 and 9 charging stands according to the customer density of businesses. -It is small in size and has a weight of 1.5 kg. -For your sample requests, express shipping can be made to anywhere with UPS or DHL. With portable desktop chargers, you can be the only one in your area and become our dealer. You can rent these devices to businesses free of charge and share the profit 50-50% with business owners. It can easily cover the cost of the device in 2-3 months, you just need to check the machines once a week and get your profit. Just contact for more details and sample submission, it's really easy to be the only one in your area and earn money. Contact with us for high quantity orders and dealership opportunities.
EAP 88 Engine: PERKINS Engine Model : 1104A-44TG2 Stand By kVA: 88 Stand By kW : 70,4 Prime kVA: 80 Prime kW : 64 Rated Current : 115,2 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1104A-44TG2 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 88 / 120 Prime Power Hp 80 / 110 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 18,5 Lt %75 LOAD 14,2 Lt %50 LOAD 9,8 Frequency Hz Power kVA 93 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1350 Weight (Open) Kg 1160 Width (Silent) Mm 1000 Length (Silent) Mm 2800 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 210 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70 Engine: PERKINS Engine Model : 1104A-44TG1 Stand By kVA: 70 Stand By kW : 56 Prime kVA: 64 Prime kW : 51 Rated Current : 92 Engine - PERKINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1104A-44TG1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 65,6 / 88,5 Prime Power Hp 59,6 / 80,5 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 14,6 Lt %75 LOAD 11 Lt %50 LOAD 8 Frequency Hz Power kVA 79 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1280 Weight (Open) Kg 1100 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 66 Engine: PERKINS Engine Model : 1103A-33TG2 Stand By kVA: 66 Stand By kW : 52,8 Prime kVA: 60 Prime kW : 48 Rated Current : 86,4 Engine - PERKINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1103A-33TG2 Number of Cylinders 3 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 60,5 / 82 Prime Power Hp 55 / 74 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 10,2 Fuel Consumption (lt / h) Lt Full Load 14 Lt %75 LOAD 10,4 Lt %50 LOAD 7,2 Frequency Hz Power kVA 66 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1200 Weight (Open) Kg 1030 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 22 Engine: PERKINS Engine Model : 404A-22G1 Stand By kVA: 22 Stand By kW : 17,6 Prime kVA: 20 Prime kW : 16 Rated Current : 28,8 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKINS Engine Model 404A-22G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 23.3:1 Bore 84 Strok 100 Displacement Lt 2,21 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 10,6 Standby Power kw / Hp 20,6 / 27,8 Prime Power Hp 18,7 / 25,2 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 14 Fuel Consumption (lt / h) Lt Full Load 5,3 Lt %75 LOAD 4 Lt %50 LOAD 2,9 Frequency Hz Power kVA 22 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 720 Weight (Open) Kg 590 Width (Silent) Mm 950 Length (Silent) Mm 2000 Height (Silent) Mm 1200 Fuel Tank Capacity Lt 125 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 1000 Engine: CUMMINS Engine Model : KTA38-G2A Stand By kVA: 1000 Stand By kW : 800 Prime kVA: 909 Prime kW : 727 Rated Current : 1308 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2A Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 895 / 1199 Prime Power Hp 813 / 1089 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 202,3 Lt %75 LOAD 153,7 Lt %50 LOAD 103,1 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9350 Weight (Open) Kg 8200 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890 Engine: CUMMINS Engine Model : KTA38-G2B Stand By kVA: 890 Stand By kW : 712 Prime kVA: 809 Prime kW : 647 Rated Current : 1165 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2B Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 789 / 1057 Prime Power Hp 711 / 953 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 176,9 Lt %75 LOAD 133,3 Lt %50 LOAD 91,3 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9300 Weight (Open) Kg 8150 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825 Engine: CUMM�°NS Engine Model : KTA38-G2 Stand By kVA: 825 Stand By kW : 660 Prime kVA: 750 Prime kW : 600 Rated Current : 1080 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 731 / 980 Prime Power Hp 664 / 890 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 167 Lt %75 LOAD 128 Lt %50 LOAD 90 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9250 Weight (Open) Kg 8100 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790 Engine: CUMMINS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 495 Engine: CUMMINS Engine Model : QSZ13-G3 Stand By kVA: 495 Stand By kW : 396 Prime kVA: 450 Prime kW : 360 Rated Current : 648 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model QSZ13-G3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 17:01 Bore 130 Strok 163 Displacement L 13 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 40 Standby Power kw / Hp 470 /629 Prime Power kw / Hp 450 /603 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 101 L %75 LOAD 74,2 L %50 LOAD 49 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 4100 Weight (Open) Kg 3625 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 440 Engine: CUMMINS Engine Model : NTAA855-G7A Stand By kVA: 440 Stand By kW : 352 Prime kVA: 400 Prime kW : 320 Rated Current : 576 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model NTAA855-G7A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 38,6 Standby Power kw / Hp 407 / 545 Prime Power kw / Hp 370/ 500 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 89,2 L %75 LOAD 67,8 L %50 LOAD 47,5 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3765 Weight (Open) Kg 3290 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.