Steel , cement , plumbing tools , sanitary items , fabrication( pipes , angles , flats , ) , paver block , natural red sand stone , binding wire , nails , tiles & all building materials.Clearing agent, transportation & shipping
Surgial instruments, dental instruments, vetrinery instrument, mani cure & buty instruments, gardinig tools & scissors of all kinds.Consultency of quality, assurity of quality from exporters in behalf of importers
Hand tools as pliers, wrenches, hammers measuring tools, screw drivers, electric power tools, pneumatic tools, construction & decoration tools as brush, bottle trap, bathtub overflow, WC fitting etc., agricultural & gardening tools, valves, bearing, fasteners as nuts, nails, bolts, door & window hardwares as handles, hinges, baluster, handrail..
Digital Oscilloscope, Xbox, Laboratory Equipment's, Research Equipment's.
Laparoscopic instruments, laparoscopic hand instruments & surgical instruments.
Laboratory equipment, laboratory instruments, packaging consumables.
Endoscopy surgery equipment, electro surgical unit, endoscope disinfector, laparascopic instruments, surgery equipment.
Surgical instruments, dental instruments, beauty case instruments, veterinary instruments, orthopedic instruments, single hand use instruments.
Scientific laboratory equipments, survey drawing instruments and medical, biology, medical furniture.Manufacturer
Microscopes, microtomes, profile projectors, educational scientific laboratory equipment.
Hospital furniture, laboratory instrument, glasswere, scientific instrument.
Product description Transformer calibrator is a new automatic instrument. We apply advanced electronic technology in the design. By directly decomposing the error signal, it is able to display the percentage, phase error and orthogonal error statistically. It s quick and energy saving. And it s especially good for live testing due to its cute dimension and light weight. Technical Parameters Working Condition: (1) Temperature: 5 (2) Relative humidity:
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Supper cutt scieser made with stainless steel 420 grade , full polished ,
Overview The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact. Technical parameter: AC current output Output accuracy Level 0.5 Phase current output (effective value) 0 40A Three merge current output (effective value) 0 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 1000VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (foundation) 20 1000Hz Harmonic number 1 20 times DC current output Output accuracy Level 0.5 Current output 0 10A / each phase, 0 20A / two superimposed Maximum output load voltage 20V AC voltage output Output accuracy Level 0.5 Phase voltage output (effective value) 0120V Line voltage output (effective value) 0210V Maximum voltage output value 0240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 201000Hz Harmonics 1 20 times
Overview The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use. Technical parameter Input voltage Three-phase four-wire 3 380 (220) V 50Hz The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1 Output current Communication 0 ~ 20A Triple semi-digital display, accuracy: level 1 Maximum output capacity 3 300VA Three-phase coarse Ambient temperature: 0 360 Move 30 per step
Product Introduction SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Technical Parameters Measuring range Dew point value 80 20 Moisture content 0 19999uLL Accuracy of measurement 0.5 60 20 1.0 80 60 The resolution of the Dew point value 0.1 Moisture content 1uLL Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20 63 needs 10s 90 needs 240s 20 60 Sampling flow 0.6L min 20 Pressure range 01.0Mpa The use of temperature 20 60 Environmental humidity 0 100 RH Storage temperature 20 80 Charging time 4 hours The whole machine size 250 150 300mm3 The weight of The machine 3.5kg
OVERVIEW Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB T507-2002, industry standard DL429.9 91 and the latest Electric Power Industry Standard DL T846.7-2004 by ourselves. This instrument, by using a single chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry. MAJOR TECHNICAL INDICATORS Output voltage 0 100KV optional Voltage distortion rate 3 Voltage raising speed 0.5 5 KVS adjustable Standing time 15min adjustable Boosting interval 5 min adjustable Boosting frequency 1 9 time s optional Booster capacity 1.5KVA Measuring accuracy 3 Supply voltage AC220V 10 50Hz1 Hz Power 200W Applicable temperature 0 45 Applicable humidity 75 RH Overall dimension 465 385 425 Transformer Oil Dielectric Strength Tester 2
Product description Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V 50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots gloves withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer. A special water tank can be customized according to needs to test 68 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots gloves
Product description The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester MOA leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests. Zinc oxide arrester tester Technical Indexes Range of reference voltage input peak 10V-200V Measurement range of full leakage current peak 100uA 10mA Measurement range of resistive current peak 100uA 10mA Measurement range of capacitive current peak 100uA 10mA Measurement range of angle 0-90 Power consumption 4W System measurement accuracy reading 5 5 words not more than 2m for harmonic current AC power supply AC 220V 10 50Hz 1 Precautions When measure the reference voltage from PT or the measuring end of the testing transformer, carefully check wiring to avoid the PT secondary or test voltage short circuit. Be careful not to wrongly connect the current and voltage sampling lines in the connecting process. In the laboratory experiment, the high voltage power supply cannot use the series excitation testing transformer.