Frank Hertz Experiment - BRAND - VIJAYANTA, INDIA 1. Frank Hertz Experiment, Model: FH 3001.
Apparatus for the Measurement of Susceptibility of Paramagnetic Solution by Quincks tube method - BRAND - VIJAYANTA, INDIA 1. Apparatus for the Measurement of Susceptibility of Paramagnetic Solution by Quincks tube method., Model: QTX-10 The Apparatus consists of : (a) Quincks tube with Multipurpose stand. (b) Sample : Fecl3. (c) Electromagnet (Tappered Poles ), Model: EMU-50T (d) Constant Current Power Supplies for Electromagnets, Model: CC-50 0 4, Amp. Suitable for EMU-50T (e) Digital Gauss Meter (Range : 0 - 2 K Gauss , 0 - 20 K Gauss), Model: DGM 100 (f) Travelling Microscope. Complete in all respects.
Determination of Plancks Constant by means of LED - BRAND - VIJAYANTA, INDIA 1. Determination of Plancks Constant by means of LED, Model: PCA-01
Electron Spin Resonance Spectrometer - BRAND - VIJAYANTA, INDIA 1. Electron Spin Resonance Spectrometer, Model: ESR - 105
Four Probe set-up for Mapping the Resistivity of Large Samples - BRAND - VIJAYANTA, INDIA 1. Four Probe set-up for Mapping the Resistivity of Large Samples, Model: FP 01
Magnetic Hysteresis Loop Tracer - BRAND - VIJAYANTA, INDIA 1. Magnetic Hysteresis Loop Tracer, Model: HLT 111
Study of Dielectric Constant & Curie Temperature - BRAND - VIJAYANTA, INDIA 1. Study of Dielectric Constant & Curie Temperature of Ferroelectric Ceramics, (Complete in all respects), Model: DEC 01
Four Probe Method Various Type - BRAND - VIJAYANTA, INDIA 1. Resistivity of Semiconductors by Four Probe Method, Model: DFP - 10 2. Resistivity of Semiconductors by Four Probe Method, Model: DFP â?? 20 3. Four Probe set-up for measuring the Resistivity of very low to highly Resistive sample at temperatures up to 2000C with PID controlled oven, Model: DFP - RM
Digital LCR Meter , Hand Held - BRAND - VIJAYANTA, INDIA 1. Digital LCR Meter, Model: LCR 4070 Range: R - 20, 200, 2K , 20K 200K , 2m , 20m L - 20H, 2mH, 20mH, 200mH, 2H, 20H. C 200pf, 2nf, 20nf, 200nf, 2µf, 20µf, 200µf, 2000µf.
Digital Pico ammeter - BRAND - VIJAYANTA, INDIA 1. Digital Pico ammeter, Model: DPM 111.
Digital Nanoammeter - BRAND - VIJAYANTA, INDIA 1. Digital Nanoammeter, Model: DNM 121
Digital D.C. Micro voltmeter - BRAND - VIJAYANTA, INDIA 1. Digital D.C. Micro voltmeter, Model: DMV 001.
Digital Lab Trainer - BRAND - VIJAYANTA, INDIA 1. Digital Lab Trainer, Model: Digi Lab - 203.
Audio Frequency Oscillator - BRAND - VIJAYANTA, INDIA 1. Audio Frequency Oscillator, (Digital Display) 20 Hz 200 KHz +/- 1% Calibration, Model: AF 712 IF YOUR STILL ANY ENQUIRY PLEASE FEEL FREE AND CONTACT US.
A.C MILLIVOLTMETER - BRAND- VIJAYANTA , INDIA 1. A.C. Millivoltmeter (TRUE RMS) - (With built-in 1 KHz Oscillator). Model : ACM
1.Strict accordance with the safety standards for design with 5 range: 500V 1000V 2500V 5000V 10000V test up to 10T�©. 2.This instrument has the function of automatic calibration and calibrate precision automatly before test 3.Actual test object live voltage measurement functionmeasure leakage currentdischarge automatly. 4.automatic measure and remenber R15Sã??R60S ã??R10min valueAutomatic display polarization index (PI) induced electric absorption test values than (DAR)and test time. 5.Anti-jamming performance is superior the interference current reaches 600 mA still ensure accuracy of test instruments. 6.Automatic discharge:quickly discharge for capacitive test object by advanced high-voltage discharge technology and real-time measurement of discharge voltage (test voltage to 0v) . 7.powered by internal rechargeable lithium battery or ac power supply the real ac and dc dual use does not affect the test accuracy. 8.digital displayautomatic display battery level and undervoltage alarm protection function. 9.Short circuit protection short circuit condition will not burn out the instrument
With the development of China's electric power industry the capacitor compensation device has been unprecedentedly developed but with it the capacitor accident rate has risen sharply and there have been serious group injury accidents. In order to prevent the occurrence of parallel capacitor accidents and ensure the safe and reliable operation of the power grid State Grid Corporation has formulated the "Measures for Preventing High Voltage Shunt Capacitor Accidents". It is clearly stated that "the measurement of the capacitance of a single capacitor of a capacitor bank should be carried out on a regular basis. It is recommended to use a measurement method that does not remove the connecting wire to avoid the failure of the casing to leak due to the force of the casing caused by the disassembly and assembly of the connecting wire". Automatic capacitance and inductance tester is designed for the problems in the measurement of high voltage shunt capacitor banks in substation sites and refers to GB3983.2-1989 "High Voltage Shunt Capacitors" DL/T840-2003 "Technical Conditions for Use of High Voltage Shunt Capacitors" and JB5346 -1998 "Series reactor" and other national standards and specially developed mainly to measure the high voltage shunt capacitor bank and reactor of reactive power compensation device. Automatic capacitance and inductance tester adopts a new generation of high-speed hybrid microprocessor which is highly integrated synchronously collects the voltage signal and current signal of the test object and automatically calculates the capacitance value inductance value and reactive power value. On-site measurement of capacitors eliminates the need to remove the connecting lines simplifying the test process effectively improving work efficiency and avoiding damage to power equipment. After the test the capacity of each phase capacitor and other parameters are automatically calculated and it is easy to discriminate the quality change of the capacitor and the connection conductor failure between devices. At the same time the automatic capacitance and inductance tester also features data storage and USB communication eliminating the need to copy data on-site and ensuring complete measurement data. Product nickname: automatic capacitance and inductance tester referred to as
After years of research and development our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge tester can be in offline mode battery as discharge load through continuously regulating discharge current constant discharge current at the set value can be realized. When discharging the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit or the set discharge time or the set discharge capacity and record all valuable and continuous real-time process data. Battery discharge tester system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access. Battery discharge tester has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report. Battery discharge tester there is perfect protection function not only sound light warning but also a clear interface tips.
Battery internal resistance tester adopts the most advanced ac discharge test method which can accurately measure the voltage and internal resistance at both ends of the battery and judge the advantages and disadvantages of the Battery capacity and technical state.Customers can choose battery internal resistance test voltage test capacity estimation according to their own situation.As the basis for matching the internal resistance of new batteries;Test the battery internal resistance before and after discharge to identify the real backward battery;Key operation and liquid crystal touch two operation mode;It can measure the accumulator in groups or in a single section. 1 Compact design light weight convenient for users to carry and operate 2 Battery internal resistance tester features: single battery measurement group battery measurement oscilloscope 3 You can use the keys or touch screens
1. The software is specially designed for DC system measurement 2. Adopts ARM DSP and 16 bit Flash memory 3. Touch panel simple operation 4. Can store review the testing results or upload data into PC 5. Module structure reliable running and reasonable design 6. Menu operation easy to use 7. Software can be upgraded via U disk 8. Data can be analyzed via DC system comprehensive analysis software installed in PC 9. large LCD display user-friendly interface 10. Full automation once set the parameters it automatically adjust AC voltage load loading resistance measure parameters record testing results and stop measuring 11. Real time on line test record single cell and battery bank voltage 12. RS232 and USB communication interface 13. Powerful data processing function: curve indication report generating accurate calculating 14. Protection function auto stop or manually stop measurement 15. Three phase digital control voltage regulator with high precision high stability 16. Module assembly structure small volume little weight easy for transporting or moving