Product Introduction The normal operation of cable-communication and electric transport completely rely on the good condition of the cable-circuit. Once the circuit breaks down and without punctually examination and repairing it will no doubt trigger the mass economic loss and bad social influence. So the electric fault measuring testing instrument is a very important tool. The intellectual testing instrument uses multiple testing methods and adopts the most advanced electronic devices and with computer and special electronic technology combining our companyâ??s successful experience of long-time exploitation on cable-fault measuring testing instruments and it is absolutely of high tech intelligence and abundant functions. Our cable-fault detector is a testing device of good integrity. It can test on the High Resistance Flashover Fault Grounding High and Low Resistance Fault Short & Off Circuit on the Cable Fault and Poor contact and etc. If being equipped with sounding method and locating instrument it can exactly detect the fault point. Furthermore it especially applies to test for various power cable and communication cable. Product nickname Cable fault meter Power Cable Fault Teater Street Light Cable Fault Teater Cable fault finder Cable fault finder Portable cable fault location system Cable fault flash meter Geo Cable Fault Teater Cable Trailer Cable Fault Teater
Product Overview TKDL Cable Identifier is designed to identify a special one within a group of cables during the power cables setting up moving maintaining and faults processing. It is suitable for all kinds of HV & LV cables. Features Can identify energized or de-energized cable. The system is composed by signal transmitter receiver transmit clamp receive clamp and some connection leads. Large power current pulse output. On-site receiving signal is clear. Light weight high sensitivity and anti-interference ability. To identify needed cable with or without electric. Accurate and fast identifying. Reliable protective circuit. Large diameter clamp suitable for all kinds of section surface cable. Build-in large power insulated transformer there is no any electrical contact between mains supply and user.
Transmission Line Test System is a new generation power transmission line frequency parameter testing system. It equips with frequency conversion testing power DFT Digital Filtering Technique which eliminates strong interference from power frequency electric field and ensures the safety of equipment convenient fast and accurate measurement. 1. Quickly and accurately test the positive sequence capacitance the positive sequence impedance zero sequence capacitance zero sequence impedance also can measure the mutual inductance and coupling capacitance between lines ; 2. High Anti-interference ability accurate and reliable measurement; 3. Easy operation equipped with large LCD and American rotating mouse and micro printer 4. Simple wiring only connecting with tested down leads to finish all line parameter measurement 5. High speed micro-controller as inner core integrated structure 6. Fast testing process one sequence parameter testing time is 1 min 7. Supplied with three groups different frequency power supply for selection: 42.5Hz/57.5Hz 45Hz/55Hz 47.5Hz/52.5Hz easily isolate the power frequency and noise wave to ensure high precision measurement of small signals.
Product Introduction The standard output of 4 phases of voltage and 3 phases of current It could combine various type of current or voltage conveniently and has diversity type of protective experiment. Every phase of voltage output is 120V and the total of the parallel current is 120A. The fourth phase voltage Ux has many functions and it can be set to be 4 type of every three voltages or synchronism checking voltage or output any value of voltage. Product Characteristics 1. Standard 4-phase voltage and 3-phase current output with 4-phase voltage and 3-phase current output can conveniently carry out various combination outputs for various types of protection tests. Single-phase voltage can output up to 120V single-phase current up to 40A (10 seconds) current three and can output up to 120A the fourth phase voltage Ux is a multi-function voltage item can be set as 4 kinds of 3U0 or check the same period voltage or a certain voltage value of the case output. 2. Single machine is easy to operate. The single machine is operated by a convenient and flexible rotating mouse through a large LCD screen all of which are displayed in Chinese. It can complete most of the field test verification work can verify all kinds of relays and microcomputer protection and can simulate all kinds of complex transient permanent and transformational faults for the whole group of tests. Boot can be used easy to operate. 3. Double operation mode connected to the computer operation through the Windows platform of the full set of Chinese operating software can carry out a variety of large complex and higher degree of automation verification work can be easily tested and scanned a variety of protection fixed value can be real-time storage test data display vector diagram draw fault waveform online print report etc. 4. Software is so powerful that can complete all kinds of high degree of automation of large complex check work such as three phase differential test auxiliary power fast cutting prepared from the cast test line protection inspection period reclosing etc. can easily test and scanning protection setting various fault playback real-time storage test data show that the vector diagram online printing report etc.
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the Ministry of Power standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made measurement (isolated The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results. The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A recommended by the national standard. The loop resistance can be directly measured under the condition of DC 100A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A gear position for users to choose; custom test time maximum The set time is 599S which is much larger than the standard 60S. It is a very stable contact resistance tester with a resolution of 0.01�¼�© in China. The performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance and high-voltage switch factory loop resistance test in electric power and power supply departments.
At present conventional QJ44 type double-arm DC bridges are commonly used in power systems to measure contact resistance and the test current of such bridges is only mA level and it is difficult to find defects in reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the high-voltage switch conductive loop the measured value is several times larger due to the influence of the oil film and the oxide layer between the contacts and the contact resistance value cannot be truly reflected. To this end the latest Ministry of Power Standard DL/T845.4-2004 "General technical requirements for resistance measuring devices: loop resistance tester" and the new version of the verification procedures JJG1052-2009 "loop resistance tester straight resistance test procedures" made a measurement ( Isolation) The measuring current of the contact resistance of switches circuit breakers etc. is not less than DC 100A and the minimum current maintenance time is not less than 60S ensuring accurate test results. The High Precision Micro Ohmmeter operator panel is ergonomically designed to meet operational habits and uses high frequency switching power supplies and digital circuit technology for the measurement of loop resistance in switch control equipment. The test current is DC 100A and 200A recommended by national standards. The loop resistance can be directly measured under the condition of DC 100A and 200A. The test result is displayed by large-screen LCD LCD and has functions of data storage output printing time setting etc. and 50A 150A gears for users to choose; custom Test time the maximum setting time is 599S which is larger than the standard 60S; it is a very stable contact resistance tester with a resolution of 0.01�¼�© in China and its performance exceeds the imported high current micro-ohmmeter. It meets the requirements of on-site high-voltage switch maintenance of electric power and power supply departments and loop resistance test of high-voltage switch factory.
ntroduction TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches. Features 1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes. 2. Need not disassemble the vacuum switch during the field test. 3. High precision. 4. With LCD easy to operate. 5. Can save print and review the test results. 6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life. 7. Light in weight easy to carry.
Product Overview TKKGG-H Series HV/LV Switch Cabinet Test Bench is mainly applied for ex-work energized testing for high voltage and low voltage cabinet manufacturers. The test bench could provide various AC/DC power source in order to detect switch cabinet. Features Reading directly: Digital meters to display current voltage power factor test value. Measuring accurately: High precision test value is accurate. Full protections: Each circuit is with air switch protection. Portable: Small size light weight easy to move.
Leakage Protector Tester is well designed and manufactured for online measuring the leakage operating current leakage non-operating current leakage operating time of the leakage protector; adopt 16 characters blue display it is convenient and intuitive. The range of leakage current is 0~1000mA range of the leakage operating time is 0~999ms. It is a product with high accuracy small size light weight exquisite appearance easy to carry is an ideal tool for a variety of leakage protector in site or in laboratory testing. 1. Handheld type small and esay to operate 2. Can measure single phase or three phase all kinds of leakage protector 3. Auto test leakage operating current 4. Directly test leakage operating time 5. LCD display intuitive reading
1.Product overview The 80X series sensor is a 26G high frequency radar level measuring instrument with a maximum measuring distance of up to 80 meters. The antenna is further optimized, and the new type of microprocessor can be used for higher speed signal analysis and processing, so that the instrument can be used in some complex measuring conditions, such as reactor, solid silo and so on. 2.principle The radar level antenna transmits narrower microwave pulses, which are transmitted downwards through the antenna. When the microwave touches the surface of the measured medium, it is reflected back and received again by the antenna system, which transmits the signal to the electronic circuit and automatically converts it into a bit signal (because the microwave propagates very fast, The time it takes for an electromagnetic wave to reach the target and return to the receiver through reflection is almost instantaneous). NYRD 807 For use: sanitary liquid storage containers, strongly corrosive containers Measurement range: 20 m Process connections: flange Medium temperature:-40 �°C 150 â?? Process pressure:-0.1~0.1MPa Fine degree: equal to 3 mm Level of protection: IP67 Frequency range: 26GHz Explosion proof grade: Exia C T6 Ga/Exd ia IIC T6 Gb Signal output: 4.20mA/HART (2 / 4)RS485/Mod bus
2T GRASS FLAIL MOWER BLADES FRONTIER Grass Brush Cutter Blades: Rapid and accurate cutting Higher durability, especially for abrasive materials Less overall blade changes = higher efficiency - 2T/ 3T/ 4T/ 8T /40T/ 80T grass cutting saw blade - Product Hardness: HRC 58~78 Degree - Material: 65 Mn steel / Alloy steel - Packaging: 1 pc per plastic bag, 100 pcs per box - Apply for Soft grass, weed, lawn, wheat, reed,rice, bush (dia1.5~2cm) - Keep out of reach of children!!! Attention:Keep out of Children
Ergonomically designed device to ensure accurate inflation of Interventional devices. Features an angled analog gauge for better viewing of pressure readings and a luminescent dial for low-lit procedures.
product brief introduction Product Introduction FRC A/D digital kilovoltmeter consists of a high stabilized resistive-capacitive type passive high-voltage divider and a precision digital voltmeter for measuring AC/DC high voltage on the site of electric power systems and in various high-voltage laboratories. Both of them with measuring cable, power supply cord, and operating manual are placed in a portable aluminium case for easy carrying and use. Product features Product Characteristics The AC/DC digital kilovoltmetre is composed of two parts of a high voltage divider and a digital kilovoltmetre. The high voltage divider is of a passive resistive-capacitive type, assembled from precision low temperature drift resistors and high quility condensers. Digital kilovoltmeter consists of ture RMS value circuit, peak values measuring circuit and digital voltmeter. Voltage divider is connected to digital kilovoltmeter by a coaxial measuring cable. The high voltage is reduced to sample value by the voltage divider, and be fed to digital voltmeter. Through function selector, the voltmeter can display DC,AC effective(RMS)value, AC peak value, and AC peak/2 value with high measuring accuracy and
Product Introduction The TKJF-208 hand-held partial discharge detector is used to detect the local discharge power supply in medium and high voltage equipment.If no discharge is detected it does not mean that there is no discharge activity in medium and high voltage equipment.Power discharges often have an incubation period and the insulation may fail for reasons other than partial discharge.If a significant discharge is detected in equipment connected to the medium-high voltage power system the equipment maintenance department should be notified immediately. product features Product Characteristics a) Screen display: high-contrast 3.5 TFT color screen. b) Data storage: 1000 groups of test data can be stored. c) Working power supply: embedded 8.4V lithium battery for 8h continuous operation. d) Power supply: input 100-240VAC output 8.4V/3A charging time 34h. e) Boundary dimension:230 * 120 * 55(mm). f) Instrument weight:1.5kg. g) Environment temperature: -25-45. h) Storage temperature: -35-60. Complete configuration: host machine sensor AC adapter connecting cable and transport case.
Product Introduction TKDL-WS automatic temperature rise test system is used for manufacturers testing the high and low voltage electrical products before delivery. It provides two functions of large current and temperature test. Convenient for user operation improves working efficiency. It applies to power plant power distribution station electrical appliance manufacturing factories scientific researching institutes laboratory. Multi channel temperature recorder uses digital synchronous sampling technology with advantages of rapid test speed high precision convenient to operate good appearance. product features Product Characteristics 1 This product is composed of large current generator voltage regulator temperature tester industrial controlling computer operation system. 2 Voltage and current displayed by industrial controlling computer software precision level is 0.5. 3 With zero position starting up protection function and emergency stop function. 4 Software test time self setting and with prompting function. 5 After current setting any deviation software can automatically adjust according to the parameters set in advance. 6 Prevent strong magnetic interference. 7 Use imported K type thermocouple: 0~1370. 8 Temperature tester with multi channel temperature monitoring measuring recording function and comparing with the test point temperature formrising temperature self alarm when the rising temperature higher than setting temperature. Any point temperatures and temperature rising value can be checked measurement error is ±1%. 9 Adopt anti interference technology combined with the hardware and software function is stable and anti-interference is strong. Four basic screens digital display picture bar chart display picture real time curve picture recall curve picture.
8085 based Thyristor firing Angle Controller Trainer - BRAND - VIJAYANTA, INDIA Study of 8085 based Thyristor firing Angle Controller Trainer, Model: TFC 901
Single Phase Voltage Commutated D.C. Chopper - BRAND - VIJAYANTA, INDIA 1. Study of Single Phase Voltage Commutated D.C. Chopper using SCR, Model: JC 703
Product Introduction Dc high voltage generator adopts high frequency pulse width modulation (PWM) technology to makeclosed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The wide temperature LCD screen adopts green back light, which enables clear display either in bright light or in darkness. High-pressure components use Dupont new filling material, making the product more stable and reliable. Products are widely used in electricity power supply departments, power transmission and transformation engineering company and preventive test of large industrial enterprises and scientific research institutes as regulated dc high voltage power supply. product features Product Characteristics 1 The output voltage is stable: the high-frequency voltage doubler circuit is applied and the new PWM pulse width modulation technology and the voltage and current double closed-loop feedback technology are applied to improve the power supply adjustment rate and the load adjustment rate so that the voltage stability is high and the ripple is small. 2 comprehensive protection: full protection function with zero protection over-voltage protection over-current protection breakdown protection protection circuit uses nanosecond-level special sensor action fast and reliable effectively protect personal and equipment safety. 3 0.75U function: Add intelligent high-precision 0.75U function one-button button press this button the voltage and current will automatically jump to the 0.75U state which is conducive to the test of zinc oxide arrester. 4 zero boost: The boost potentiometer starts from zero adopts imported multi-turn potentiometer the boosting process is stable and the adjustment precision is high. 5 over-voltage setting: over-voltage setting uses digital dialing switch easy to operate and has a high setting accuracy. 6 one-piece design: the choice of integrated design Host and double pressure cylinder is placed in a chassis. The imported high-frequency high-voltage rectifier diode is used to make the double-pressure cylinder small in size improve the efficiency of the whole machine and is easy to carry. 7 reliable performance: the key components use high-performance imported components the pressure roller is coated with special insulating materials good electrical performance strong moisture resistance no leakage. 8 the operation is simple: the instrument interface each function button the layout is reasonable the instructions are clear easy to learn and use.
product brief introduction Product Introduction The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance, and light weight. 3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive. 4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
product brief introduction Product Introduction The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance, and light weight. 3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive. 4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install. warning 1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit. 2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity. 3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire. 4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.