ALSTOM GBCDG11AF016SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF016SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA /1.3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.1 - 0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125 792 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
GBCDG11AF018SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF018SACH Relay type CDG 11 Special Case size 1D V 10T Application E/F Current setting 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Burden 3 VA Operating time 1.3 secs Taps Std Frequency 50 Hz Flag Yes Mounting Flush Name Plate RFG9125 793 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
ALSTOM GBCDG11AF106SACH SELF-POWERED INVERSE TIME O/C ORE/F 60HZ Technical Specifications Model No CDG11AF106SACH CDG11 Application - E/F Burden / D.M.T - 3Va / 3 Secs. C.T. Secondary - 1 Amp Case Size - 1D V 10T Contacts - 2 N/O S/R Current Setting - 0.1 - 0.4 Amps. Flag - Yes Mounting - Flush Taps - STD Frequncy - 60 Hz Note:-In NamePlate write 60 Hz in place of 50 Hz Name Plate RFG9126792 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
Alstom Gbcdg11af8101kch Idmt O/c Relay, Bss Curve,ac Series Trip Technical Specification Model No. Cdg11af8101kch Application O/c Burden / D.m.t 3va / 3 Secs. C.t. Secondary 5 Amp C.t. Case Size 1d V 10t Contacts (S/r or H/r) 2 N/o 2 N/c H/r E/f or U/v Setting Not Aplicable Flag Yes Frequency 50 Hz Mounting Flush O/c or O/v Setting 2.5 - 10 Amps. Name Plate-1 Rfg9126674 Outline Drawing Mfj012 Wiring Diagram Madz821-17
ALSTOM GBCDG11AF8104KCH INV.TIME O/C OR E/F RELAY FOR AC SERIES Technical Specifications Model No : CDG11AF8104K(M) CDG11 S/T APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126695 Outline Diagram MFJ012 Wiring Diagram MADZ821-17
ALSTOM GBCDG11AF9007ACH INVERSE TIME E/F RELAY MULTI-AUX-VOLTAGE Technical specification Relay model no CDG11AF9007ACH Relay type CDG 11 Case size 1D S/E Application E/F Current setting 1 to 4 amps C.T.Secondary 5 amps Taps Std Burden 3 VA Operating time 3 secs Frequency 50 Hz Aux.voltage vdc 30-50 / 100-125 V 220-250 V dc Contacts shunt 2 N/O S/R Flag Yes Mounting Type Flush Name plate RFG9126 796 Outline drawing MFJ 012 Wiring diagram MADZ 802.26-1
Alstom Gbcdg21af001zmch Obsoleted Model Ref.gbcdg21af101zmch Obsoleted Model Ref.gbcdg21af101zmch
Alstom Gbcdg21af003zmch Obsoleted Model Ref.gbcdg21af102zmch Obsoleted Model Ref.gbcdg21af102zmch
ALSTOM GBCDG21AF035SYCH IDMT EARTH FAULT RELAY WITH H/SET CAG13 TECHNICAL SPECIFICATION Relay Model CDG21AF035SYCH Relay Type CDG 21 SPR Application E/F Case Size 1D V 10T C.T. Secondary 1 Amp E/F Setting 0.1 TO 0.4 Amps Frequency 50 Hz Burden / D.M.T 3 Va / 1.3 Secs Contacts 2 N/O 2 N/C H/R Flag Yes High Set Type CAG13 Highset Contacts 2 N/O S/R Highset E/F Setting 2 TO 8 Amps Mounting Flush Name Plate RFG9125 792 Outline Drawing MFJ 012 Wiring Diagram MADZ821.29-1
ALSTOM GBCDG21AF101ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Technical Specifications Model No : CDG21AF101ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 12.5-100 Amps. MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate RFG9126 674 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
GBCDG21AF101ZNCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN TECHNICAL SPECIFICATION Relay Model CDG21AF101ZNCH CDG21/CAG17(MRK-III) Application - O/C Case Size - 1D V 10T Burden / D.M.T - 3Va / 3 Secs C.T. Secondaray - 5 Amp C.T. Contacts - 2 N/O 1 N/C H/R Flag - Yes Frequency - 50 Hz High Set Type - CAG17 Highset Contacts - 2M S/R Highset O/C Setting - 12.5-100 Amps. Mounting - Flush O/C Setting - 2.5 - 10 Amps. Name Plate RFG9126-774 Outline Drawing MFJ 012 Wiring Diagram MADZ821.32
ALSTOM GBCDG21AF102ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF102ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5-20 Amps. MOUNTING - FLUSH O/C OR O/V SETTING - 0.5 - 2 Amps. Name Plate RFG9126 671 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
ALSTOM GBCDG21AF102ZNCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF102ZNCH CDG21 APPLICATION O/C BURDEN / D.M.T 3VA / 3 SEC. C.T. SECONDARY 1 AMP CT. CASE SIZE 1D V 10T CONTACTS (S/R OR H/R) 2 N/O 1 N/C H/R FLAG YES FREQUENCY 50 HZ HIGH SET TYPE CAG17 HIGHSET CONTACTS 2M S/R HIGHSET O/C SETTING 2.5-20 Amps. MOUNTING FLUSH O/C SETTING 0.5 - 2 Amps NAME PLATE-1 RFG9126 671 OUTLINE DRAWING MFJ 012 WIRING DIAGRAM MADZ821.32
GBCDG21AF103ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF103ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 5 - 40 Amps. MOUNTING - FLUSH Name Plate RFG9126 696 Outline Diagram MFJ 012
ALSTOM GBCDG21AF104ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF104ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 5 - 40 Amps. MOUNTING - FLUSH Name Plate RFG9126 695 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
ALSTOM GBCDG21AF104ZNCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN RELAY MODEL CDG21AF104ZNCH CDG21 APPLICATION E/F BURDEN / D.M.T 3 VA / 3 SEC. C.T. SECONDARY 5 AMP C.T. CASE SIZE 1D V 10T CONTACTS (S/R OR H/R) 2 N/O 1 N/C H/R E/F OR U/V SETTING 0.5 - 2 Amps. FLAG YES FREQUENCY 50 HZ HIGH SET TYPE CAG17 HIGHSET CONTACTS 2M S/R HIGHSET E/F SETTING 5 - 40 Amps. MOUNTING FLUSH NAME PLATE-1 RFG9126 695 OUTLINE DRAWING MFJ 012 WIRING DIAGRAM MADZ821.32
ALSTOM GBCDG21AF105ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Technical specification Relay Model No - CDG21AF105ZMCH CDG21/CAG17(MRK-III) Case size - 1D V 10T Application - E/F Current setting - 0.2 to 0.8 amps Burden / D.M.T - 3 VA / 3 sec C.T.Secondary/Frequency - 1 amps /50 Hz Contacts (S/R OR H/R) - 2 N/O S/R Flag - Yes Mounting - Flush High set type - CAG17 Highset contacts - 2M S/R Highset E/F Setting - 1 to 8 amps Name Plate RFG9126 793 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
ALSTOM GBCDG21AF105ZNCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF105ZNCH CDG21 APPLICATION E/F BURDEN / D.M.T 3VA / 3 SEC. C.T. SECONDARY 1 AMP CT. CASE SIZE 1D V 10T CONTACTS (S/R OR H/R) 2 N/O 1 N/C H/R E/F SETTING 0.2 - 0.8 Amps. FLAG YES FREQUENCY 50 HZ HIGH SET TYPE CAG17 HIGHSET CONTACTS 2M S/R HIGHSET E/F SETTING 1 - 8 Amps. MOUNTING FLUSH NAME PLATE-1 RFG9126 693 OUTLINE DRAWING MFJ 012 WIRING DIAGRAM MADZ821.32
GBCDG21AF106ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF106ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 Secs. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 1 - 8 Amps MOUNTING - FLUSH Name Plate RFG9126 692 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
Gbcdg21af106znch Idmt Earth Fault Relay With High Set Relay Model Number Cdg21af106znch Cdg21 Application E/f Burden 3va C.t. Secondary 1 Amp Ct. Case Size 1d V 10t Contacts (S/r or H/r) 2 N/o 1 N/c H/r D.m.t 3 Sec. E/f or U/v Setting 0.1 to 0.4 a Flag Yes Frequency 50 Hz High Set Type Cag17 Highset Contacts 2m S/r Highset E/f Setting 1 to 8 a Highset O/c Setting Not Applicable Mounting Flush O/c or O/v Setting Not Applicable Name Plate-1 Rfg9126 692 Outline Drawing Mfj 012 Wiring Diagram Madz821.32