Gbcdd21pf053sbch Directional Idmt Relay Self Powered Technical Specification Cdd21pf053sbch Relay Type Cdd21 Case Size 1.5d S/e Application E/f C.t.secondary 5 Amps Current Setting 1 to 4 Amps Voltage 63.5 to 190v Ac Frequency 50 Hz Burden 3 Va Operating Time 1.3 Secs Mta I Lead/lag Volt. 14 Lag Deg Contacts 3m S/r Output Contacts 2m S/r Taps Std Name Plate Rfg9125 043 Outline Drawing Mfj 013 Wiring Diagram Mpdz801.23
ALSTOM GBCDD21PF055SJCH DIRECTIONAL IDMT RELAY SELF POWERED Technical specification RELAY MODEL NO CDD21PF055SJCH RELAY TYPE - CDD 21 CASE SIZE 1.5D S/E APPLICATION O/C CURRENT RATING 1 Amps CURRENT SETTING 0.5 - 2 Amps VOLTAGE 110V AC 50 Hz BURDEN 3 VA OPERATING TIME 1.3 Secs MTA I LEAD/LAG VOLT. 30 LEAD DEG CONTACTS 2M 2B H/R OUTPUT CONTACTS 2M 1B H/R TAPS STD NAME PLATE RFG 9125 011 OUTLINE DRAWING MFJ 013 WIRING DIAGRAM MPDZ 801.24
ALSTOM GBCDD21PF9054BCH SELF-POWERED DIR. INVERSE TIME O/C OR E/ Technical specification Relay model no CDD21PF9054BCH Relay type CDD 21 Case size 1-1/2D Vert.10T Application E/F Current setting 0.5 - 2.0 amps Aux.current or voltage 100 - 250V dc Burden 3 VA C.T.Secondary 5 amps Contacts (S/R OR H/R) 2 N/O S/R D.M.T 3 secs Taps Std Flag Yes Mounting Flush Frequency 50 Hz MTA Phase-char angle 60 Deg V.T/P.T Secondary 63.5V ac Name plate RFG9126-042 Outline drawing MFJ 013 Wiring diagram MPDZ 801-10-1
GBCDG11AF002SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF002SC(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5-2 Amps. Name Plate RFG9126 771 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF004SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF004SACH CDG11 APPLICATION - E/F BURDEN - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126-795 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
GBCDG11AF013SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF013SCCH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 1 - 4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125 796 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF014SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : - CDG11AF014SA(M) CDG11 APPLICATION - E/F BURDEN /D.M.T - 3VA /1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125-795 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF014SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF014SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125 795 Outline Diagram MFJ012 Wiring Diagram MADZ802-64-1
Alstom Gbcdg21af001zmch Obsoleted Model Ref.gbcdg21af101zmch Obsoleted Model Ref.gbcdg21af101zmch
ALSTOM GBCDG21AF101ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Technical Specifications Model No : CDG21AF101ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 12.5-100 Amps. MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate RFG9126 674 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
ALSTOM GBCDG21AF102ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF102ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5-20 Amps. MOUNTING - FLUSH O/C OR O/V SETTING - 0.5 - 2 Amps. Name Plate RFG9126 671 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
GBCDG21AF106ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF106ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 Secs. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 1 - 8 Amps MOUNTING - FLUSH Name Plate RFG9126 692 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
Gbcdg21af106znch Idmt Earth Fault Relay With High Set Relay Model Number Cdg21af106znch Cdg21 Application E/f Burden 3va C.t. Secondary 1 Amp Ct. Case Size 1d V 10t Contacts (S/r or H/r) 2 N/o 1 N/c H/r D.m.t 3 Sec. E/f or U/v Setting 0.1 to 0.4 a Flag Yes Frequency 50 Hz High Set Type Cag17 Highset Contacts 2m S/r Highset E/f Setting 1 to 8 a Highset O/c Setting Not Applicable Mounting Flush O/c or O/v Setting Not Applicable Name Plate-1 Rfg9126 692 Outline Drawing Mfj 012 Wiring Diagram Madz821.32
GBCDG21AF111ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF111ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 12.5 - 100 Amps MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate RFG9125 674 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
ALSTOM GBCDG21AF114ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF114ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN /D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 5 - 40 Amps. MOUNTING - FLUSH Name Plate RFG9125 695 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
Gbcdg21af116znch Idmt Earth Fault Relay With High Set Technical Specification Relay Model Cdg21af116znch Relay Type Cdg21 Application E/f Burden 3va C.t. Secondary 1 Amp Ct. Case Size 1d V 10t Contacts (S/r or H/r) 2 N/o 1 N/c H/r D.m.t 1.3 Sec E/f or U/v Setting 0.1 to 0.4 a Flag Yes Frequency 50 Hz High Set Type Cag17 Highset Contacts 2m S/r Highset E/f Setting 1 to 8a Highset O/c Setting Not Applicable Mounting Flush O/c or O/v Setting Not Applicable Name Plate-1 Rfg9125 692 Outline Drawing Mfj 012 Wiring Diagram Madz821.32
ALSTOM GBCDG21AF117ZMCH IDMT OVER CURRENT RELAY WITH HIGH SET Relay Model No. CDG21AF117ZMCH Relay Type CDG21 Size 1D V 10T Current Setting 2.5 to 10 Amps Frequency 50 Hz Application O/C Contacts 3 N/O S/R Output Contacts 2 N/O S/R Taps Std C.T. Secondary 5 Amps Burden 3 VA Operating Time 3 Sec High-set Contacts 2 N/O S/R High-set Cur. Setting O/C 5 to 40 Amps High-set CAG 17 Nameplate RFG9126 674 Outline Arrangement MFJ 012 Wiring Diagram MADZ821.31
MITSUBISHI PLC , ALL MODEL ARE AVAILABLE. Mitsubishi PLC Module FX5-4AD-ADP Mitsubishi PLC Module FX2N-2DA Mitsubishi PLC Module FX3U-CNV-BD Mitsubishi PLC Module FX2N-8DA Mitsubishi PLC Module FX3U-485ADP-MB Mitsubishi PLC Module FX3U-232ADP-MB Mitsubishi PLC Module FX3U-ENET-ADP Mitsubishi PLC Module FX3U-4AD-TC-ADP Mitsubishi PLC Module FX2N-4DA
ALSTOM GBCDG21AF8202SKCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Technical specification Model Number CDG21AF8202SKCH Relay type CDG21 CASE SIZE 1D S/E APPLICATION O/C S/T CURRENT SETTING 2.5 TO 10 AMPS CONATCTS 2M 2B H/R OUTPUT CONTACTS 2M 2B H/R TAPS STD C.T.SECONTARY 5 AMPS BURDEN / OPERATING TIME 3 VA / 3 SECS. HIGH SET CONTACTS 2M S/R HIGH SET CAG 17 FREQUENCY 50 HZ HIGH SET CUR.SETTING 12.5 TO 100 AMPS NAME PLATE RFG9126 774 OUTLINE DRAWING MFJ 012 WIRING DIAGRAM MADZ821.33
ALSTOM GBCDG21AF9068ZACH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Technical specification CDG21AF9068ZACH Relay type CDG21 CASE SIZE 1D SE APPLICATION O/C CURRENT SETTING IDMT 0.5 TO 2 AMPS C.T.RATING 1 Amp. CURRENT SETTING HIGH SET 5 TO 20 AMPS TAP STD FREQUENCY 50 HZ BURDEN / OPERATING TIME 3 VA / 3 SECS. HIGH SET UNIT 2M S/R WITH FLAG AUX.VOLTAGE 100-125/ 220-250V DC NAME PLATE RFG9126 771 OUTLINE DRAWING MFJ 012 WIRING DIAGRAM MADZ802.58-1