8 Isolated Digital output and 4 Isolated digital input * Support 8 Isolated digital output channels * Open Collector Output (NPN) * Support 4 isolated digital input channels * Input channel support max. 50Hz counter * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
8-ch ISO DI and 3-ch DC-SSR Output with LED display * Support 8 isolated digital input channels * Input channel support max. 50Hz counter * Support 3 DC-SSR output channels * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
5-ch ISO DI and 5-ch AC-SSR Output with LED display * Support 4 isolated digital input channels * Input channel support max. 50Hz counter * Support 5 AC-SSR output channels * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-8067AD 8 channels Isolated Relay Output (5A/250Vac, 5A/30Vdc) * 8-Channels relay Output * Normal Open Relay Output(Form A) * Relay contact rating 5A/250Vac, 5A/30Vdc. * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
EDAM-9052AB Ethernet 8-DI ISO (Dry/Wet contact) and ISO 8-DO module * Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP * Ethernet 10/100 Based-T Communication * Support 8 isolated digital output with Open Drain. * Provide 3A/per output channel. * Provide Pulsed/delay Output Mode * Support 8 Isolated digital Input Channels * Provide Counter/ Frequency Inputs Mode * Support Dry/ Wet Contact Inputs * Fully Photo-Isolation 3750Vrms
16-CH Input module W/LED * Support 16 isolated Input channels. * Input channel support max. 50Hz counter * Programmable Host Watchdog Timer for Host Failure Protection. * Support Modbus and ASCII Format Protocol.
8 Isolation with differential AC Input (max. 80VAC), with LED * Support 8 isolated differential AC digital input * EMS Protection (IEC-61000-4-2 (EDS)Level 4) * Programable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-9050AB Ethernet ISO 12 DI (wet contact) / 6 DO module * Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP * Ethernet 10/100 Based-T Communication * Support 6 Isolated digital output channels (NPN). * Provide Pulsed/delay Output Mode * Support 12 Isolated digital Input Channels * Provide Counter/ Frequency Inputs Mode * Support Wet Contact Inputs * Fully Photo-Isolation 3750Vrms * Status LED indicator
14 Channels Isolated Digital Input Module * Support 8 non-isolated digital output *Open Collector Output (NPN) * 14 Isolated Single-Ended input channels * Input channel support max. 50Hz counter * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
16 Ch. Non-Isolated Digital Output * Support 16 non-Isolated digital output ch. * Open Collector Output (NPN) * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format Protocol
4-ch ISO DI and 4-ch relay Output with LED display * Support 4 isolated digital input channels * Input channel support max. 50Hz counter * Support 4 relay output channels(RL1~RL4) * RL1,RL2: Form A, RL3,RL4: Form C * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
5-ch ISO DI and 5-ch DC-SSR Output with LED display * Support 4 isolated digital input channels * Input channel support max. 50Hz counter * Support 5 DC-SSR output channels * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-8015 6-ch ISO RTD Input module * Support PT100, PT1000, Balco 500, NI604, NI1000 RTD types * Protocol MODBUS RTU, ASCII Command * Support isolated input channels * Fully photo-isolation 3750Vrms * Wide supply voltages (10_30V) * Built-in TVS/ESD protection * Burn-out auto detection
EDAM-8018A 8 Isolated Analog/Thermocouple Temperature Input Module * Support Thermocouple J.K.T.R.S.E.B.N.C Type * Protocol MODBUS RTU, ASCII Command * Support Isolated input channels * Fully photo-isolation 3750Vrms * Wide supply voltages (10-30V) * Built-in TVS / ESD protection * Burn-out auto detection
4 analog output and 4 digital input channels module * 4 isolation analog output channel . * 14 bits Analog Resolution * Programmable voltage/current range with slew rate. * 4 channels isolation digital input * 3000 Vrms isolation voltage for A/O channel * Programmable power-on value and safe value * Programmable host watchdog timer for host failure protection. * Support ASCII format and Modbus-RTU protocol
13 Channels Isolated Digital Output Module * 13 Isolated Single-Ended output channels * Open Collector Output (NPN) * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
8 Non-Isolated digital input and 8 Non-Isolated digital output (NPN) * Support 8 non-Isolated digital output *Open Collector Output (NPN) *Support 8 non-isoloated digital input channels *Input channel support max.50Hz counter * Programmable Host Watchdog Timer for Host Failure Protection *Support Modbus RTU and ASCII Format Protocol
8 Isolation with differential AC Input (max. 250VAC), with LED * Support 8 isolated differential AC digital input * EMS Protection (IEC-61000-4-2 (EDS)Level 4) * Programable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-9061A 6-channel Digital Input and 6 RELAY (0.6A/AC, 2A/DC) Output module * Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP * Ethernet 10/100 Based-T Communication * Support 6 relay channels. (Form A) * Provide Auto-Off Time of digital output * Support Automatic DIO Synchronization func. * Support 6 Isolated digital Input Channels * Provide Counter Inputs Mode * Support Dry/Wet Contact Inputs * Provide PoE function(only for EDAM-9461) * Fully Photo-Isolation 3750Vrms
EDAM-8000 series: RS-485 Digital and Analog I/O Remote Control Modules Overview: EDAM-8000 is a series of data acquisition modules. It provides a total solution of the data acquisition network and control system. Including the communication modules, the analog input modules, the analog output modules, and the digital I/O modules. You can remotely control up to 256 EDAM modules on RS-485 network.