Power table is arranged with fine table top with capacity of bearing heavy weight upto 80 kg. Moreover, it provides flexibility in the movement.
Specifications
Height minimum : 675 mm
Height maximum : 875 mm
Vertical traveling range : 200 mm
Load maximum : 80 kg.
Table top size : 570x, 400x, 24mm
Power supply ac : 220/110v, 50/60 hz
Power consumption : 20 kg.
Weight (actual) : by rotating wheel manually
Up & down movement : by feather touch switch mounted with wooden top.
Beam splitter is another unique product of visine, that splits a beam of light in two. It is used in accessory for ccd camera. The bifurcated light is passed to eyepieces which is also provided with a focusing ring. Thereby it increases the image clearity.
Features
Beam splitter uses two cube prisms with semi-reflective coatings to direct a portion of the light entering the beam splitter to the accessory / camera port.
He remaining portion of the light passing through the prism goes to the eyepieces.
Provides additional comfort to around ears and nose. It provides a high impressive performance with robust frame making work easy going.
Specifications:
Magnification:3.5x
Visual field diameter:30mm
Working distance:300mm
Weight:100 gram without box
Features
Large field of view bright clear image
Long lasting and comfortable
Swing out of view when not in use
One can use his power glasses in the same frame
Also available with comfortable headband.
COLD LIGHT
Cold, Halogen light source with advanced filter to absorb over 95% of the heat generating from light source.
BACK-UP BULB SYSTEM
Automatic Activation of the second bulb in case of the burning of the primary lamp with visual indicator of burnt bulb, to ensure the continuity of the surgical procedure. The replacement of the bulbs no requires any tool.
AERODYNAMIC LIGHT-HEAD
Aerodynamic sealed, light head with smooth surface to grant the max hygieny in operating room and over the surgical site.
SHADOW REDUCTION AND DEEP CAVITY ILLUMINATION
The multifacets reflector with more than 1000 facets, reflect and concentrate the light beam directly from each facet to the focused light pattern without dark spots, rings and irregularities, granted a light beam without shadow.
AustinMoore Prostheses:-
Austinmoore Standard Stem
Head Dia =37mm to 43mm
Stem Length=127mm
Stem Thickness=10mm
Stem Width=25mm
Degree of Device=135 degrees
Hole Dia=6.00mm
Made in ss 316 L
Austinmoore Standard Stem
Head Dia =44mm to 49mm
Stem Length=140mm
Stem Thickness=10mm
Stem Width=25mm
Degree of Device=135 degrees
Hole Dia=6.00mm
Made in ss 316 L
Austinmoore Standard Stem
Head Dia =50mm to 56mm
Stem Length=150mm
Stem Thickness=10mm
Stem Width=25mm
Degree of Device=135 degrees
Hole Dia=6.00mm
Made in ss 316 L
There is no further need to debate the virtues of monopolar versus bipolar technology for minor surgery. The Greenland RFS-4000K affords surgeons the ability to utilize both monopolar and bipolar modalities at, the frequency scientifically and clinically proven to produce the least amount of lateral heat and tissue alteration
Specification:
1. Sample rate: 1000Hz, simultaneous 12 leads recording
2. Resolution:12bit
3. Power: 5.0V (DC)
4. Patient Insulation: 4000V AC
5. Defibrillation Protection: Built-in box
6. Digital resolution: 2ª¦V
7. Frequency response: 0.05-250 Hz
8. Common mode rejection: >90dB
9. Input impedance: >10Mª+
10. Time constant: í¦3.2 s
11. Max electrode potential: í+300mV DC
12. Dynamic range: í+10mV
13. Isolate voltage: 4000V
14. Current leak: <10ª¦A
15. Patient cable: standard 10-wire, 15-pin D connection
16. PC interface: RS232
Feature:
1. Intuitive windows software interface
2.Quick and accurate analyzing system
3.Special editing system of r point
4.Optional main channel
5.Perfect analysis function of st segment
6.The analysis function of t wave of allchannels and t wave trend graph
7.Review of the ecg trend graph of every time
8.The analysis system of hrv, providing the regular sdnn, sdann, rmssd, lf, hf, time domain, and frequency domain
Qt analysis and qt trend graph
Acquire pacing ecg directly without separate channel, also have the functions of vcg, lpg, high frequency ecg, fcg.
Function (9 functions):
1. ECG: 12-lead resting PC-ECG with auto interpretation
2. VCG: Vector-cardiograph with auto interpretation
3. TVCG: Timed Vector-cardiograph
4. FCG: Frequency ECG (unique technique to detect ischemia and CAD)
5. HFECG: High Frequency ECG
6. SAECG(VLP): Signal Averaged ECG or Ventricular Late Potentials, time domain and 3-D frequency domain)
7. QTD: QT Dispersion with chroma map
8. HRV: Heart Rate Variability (time domain, 3-D frequency domain, Lorenz poincare plots
9. PMECG: Pacemaker ECG analysis
Package list:
1. Software CD
2. Dongle key
3. ECG acquisition box
4. Banana type ECG cable
5. USB data cable
6. Chest electrodes
7. Limb electrodes
8. Ground wire for earthing
9. Manual