Feature PORTABLE AND SAFE ATTRACTIVE DESIGN ERGONOMICALLY DESIGNED TO MINIMIZE HAND FATIGUE DURING A PROLONGED PERIOD OF USAGE DIVERSE PACKING METHODS DIVERSE COLORS(MADE IN ANY COLOR OF CHOICE) REPLACEMENT SAW BLADE AVAILABLE Specification: BLADE LENGTH(mm) : 240 mm BLADE THICKNESS : 1.30 t TEETH PITCH : 3.50 mm PACKING : IN/CT 12 PCS/72 PCS
Feature PORTABLE AND SAFE ATTRACTIVE DESIGN ERGONOMICALLY DESIGNED TO MINIMIZE HAND FATIGUE DURING A PROLONGED PERIOD OF USAGE DIVERSE PACKING METHODS DIVERSE COLORS(MADE IN ANY COLOR OF CHOICE) REPLACEMENT SAW BLADE AVAILABLE Specification: BLADE LENGTH(mm) : 270 mm BLADE THICKNESS : 1.30 t TEETH PITCH : 4.00 mm PACKING : IN/CT 12 PCS/72 PCS
Gauge Instrument, since we started our business as SJ Tech in July of 2017.
DISPLAY MEASUREMENT SYSTEM: Equipment that tests the Reliability of OLED material more precisely and quickly RTS-101, the Next-Generation High-Precision Test Multi-Channel Source Measure Unit - Support of CC/CV Output Mode, Multi-Channel SMU Multi-Channel Light Intensity Measurement Unit - Light Intensity Measurement Circuit using Photo-Diode Various expandability, stability, and user convenience software - Support room temperature, temperature control, UV degradation measurement - Data loss prevention function and data processing / aggregation function Applications Evaluation of display luminous reliability, Evaluation of luminous material brightness (relative luminance) lifetime Key components Reliability meter, Element fixture device, Measurement/viewer software, Facility operating PC (Option) UPS, Individual temperature control element fixing device, Constant temperature/high temperature maintenance device
EV Measurement System: Main Functions - EV Electronic Component System Inspection (Checking with Functional Movement) - Measurement of Voltage/Current of Main Components - Data Monitoring through MCU CAN Communication Applications : Reliability evaluation of Electric vehicle electronic units Specification : Automotive electronic units: provided according to the customer's car model Key components : Electronic unit mounting enclosures, Measurement probes, Oscilloscopes, Multimeters
M(Magneto)-EL(Electroluminescence) Measurement System (CTS-104): Applications Measurement of luminescence intensity change according to the influence of magnetic field of organic materials (MEL) Specification Magnetic field range: 1mT to 270mT Input Range: (Voltage/Current) 20V / 1A Key components Permanent Magnet, Source Meter, Photo Detector, Multimeter, Automatic Transfer Device, Element fixing device, Fiber Optic Measurement/Analysis Software, Operating PC (Option) Temperature Control Element Fixing Device, Low Temperature Cryostat
Applications Evaluation of light characteristics / uniformity of Flat Display, BLU, and Light Source for Lighting Specification Contact separately Key components Power supply, Optical Test & Measuring Equipment, Automatic transfer device, Measurement/Analysis software, Facility operating PC(option) temperature control unit
PL LIFE TIME Measuring Equipment (LTS-101) Features: Multi-channel long-term measurement Applications : Color filter performance measurement Specification : Contact separately Key components : Luminance meter (Konica Minolta CS-2000(A), Topcon SR-3AR(UL2), Photo research PR series, etc.) Measurement/Viewer Software Facility operation PC
Applications : Measurement of J (current density), V (voltage), L (luminance) characteristics of display devices such as OLED/LED/QLED Features: Various component interworking support is available Improve measurement speed through optimization. Provides an intuitive user-friendly UI. Key functions: Measurement of JVL Characteristics Pre-Test function (lighting test and manual measurement, etc.) Measurement data list Graph type editing function Automatic merging of measurement data and report file creation functions Data storage format, display unit, and number of significant digits setting functions
Transient Electroluminescence Measurement System(CTS-103): Applied Areas & Characteristics - OLED Device : TEG, CELL(Panel) - QLED Device - uLED Device - T-EL(Transient Electroluminescence) : Rising/Falling Characteristic Measurement, Electron Mobility - Data Analysis : Slop Calculation, Normalization, Turn-on Time(T0) Calculation, Raise/Falling Sections, EL Reserve Dataprocessing Applications :Measurement and analysis of electroluminescence response characteristics Specification : Contact separately Key components : Pulse signal generator, Oscilloscope, Photodetector, Element fixing device, Measurement/analysis software, Facility operating PC (Option) Optical system, Temperature control device
PL - AOI Equipment Features and Benefits: Micro LED Crack High Resolution Inspection Applications : Micro LED Specification :Contact separately Key components :Contact separately
Applications: Impedance measurement, capacitance VS voltage measurement Specification :Contact separately Key components :Contact separately
Test Fixture(JIG): 1. Lifetime JIG 2. TOF JIG 3. LOW Temperature Control JIG 4. OPD JIG 5. IVL JIG 6. T-EL JIG Applications Fixing device of Light-emitting / light-receiving element and semiconductors Specification : - Select the size according to the sample size and intended use. - Electrical Contact: Spring Pins - Apply On / Off and polarity reversal switches. Characteristic: - Sample customized design and production - Produce a sealed or external gas injection type according to the application. - Support 2, 4-terminal measurement and apply various input/output connectors - Can combine with various measuring equipment and light sources
OLED Reliability(RTS-101): Equipment that tests the Reliability of OLED material more precisely and quickly RTS-101, the Next-Generation High-Precision Test Multi-Channel Source Measure Unit - Support of CC/CV Output Mode, Multi-Channel SMU Multi-Channel Light Intensity Measurement Unit - Light Intensity Measurement Circuit using Photo-Diode Various expandability, stability, and user convenience software - Support room temperature, temperature control, UV degradation measurement - Data loss prevention function and data processing / aggregation function Applications Evaluation of display luminous reliability, Evaluation of luminous material brightness (relative luminance) lifetime Key components Reliability meter, Element fixture device, Measurement/viewer software, Facility operating PC (Option) UPS, Individual temperature control element fixing device, Constant temperature/high temperature maintenance device
IVL Characteristic Measurement Test System IVL Characteristic Test System (CTS-101): Available to compose the Multi-Channel Measurement Automated Facilities Mainly-applicable components SMU : Keithley 2400, 2450, 2601, 2635B Spectroradiometer : (Konica Minolta) CS-2000(A), (TOPCON) SR-3AR, SR-UL2, (Photo Research) PR-650, PR-670 Applications Evaluation of the electrical/optical properties (I-V-L) of light-emitting devices or materials Key components Keithley 2450 or 2635B Luminance meter (Konica Minolta CS-2000(A), Topcon SR-3AR(UL2), Photo research PR series, etc.), Measurement / viewer software, facility operation PC Multi-channel / automation equipment (option)
PL LIFE TIME Measuring Equipment (LTS-101) Features: Multi-channel long-term measurement Applications : Color filter performance measurement Specification : Contact separately Key components : Luminance meter (Konica Minolta CS-2000(A), Topcon SR-3AR(UL2), Photo research PR series, etc.) Measurement/Viewer Software Facility operation PC
M(Magneto)-EL(Electroluminescence) Measurement System (CTS-104): Applications Measurement of luminescence intensity change according to the influence of magnetic field of organic materials (MEL) Specification Magnetic field range: 1mT to 270mT Input Range: (Voltage/Current) 20V / 1A Key components Permanent Magnet, Source Meter, Photo Detector, Multimeter, Automatic Transfer Device, Element fixing device, Fiber Optic Measurement/Analysis Software, Operating PC (Option) Temperature Control Element Fixing Device, Low Temperature Cryostat
Impedance Measurement Equipment Applications: Impedance measurement, capacitance VS voltage measurement Specification :Contact separately Key components :Contact separately
OLED Mobility(TOF) Measurement System(CTS-102) Characteristics & Strengths -Automated TOF Data Measurement System -Owing to the application of ND-Yag Laser, it could be Semi-Permanently used without Consumables. -With the improvement of noise characteristic, it is possible to measure the TOF Characteristic Signal in Low-Voltage Field Bias. -Convenient Measurement of GUI & Automated Sequence Function -Zero-Field Mobility Analysis Function Applications :Measurement and Analysis of Electronic Material Charge Mobility Specification : Contact separately Key components :Laser, oscilloscope, Source meter, Optical system, Element fixing device Measurement / Analysis software, Facility operation PC Temperature control device (option)
OLED Reliability(RTS-101): Equipment that tests the Reliability of OLED material more precisely and quickly RTS-101, the Next-Generation High-Precision Test Multi-Channel Source Measure Unit - Support of CC/CV Output Mode, Multi-Channel SMU Multi-Channel Light Intensity Measurement Unit - Light Intensity Measurement Circuit using Photo-Diode Various expandability, stability, and user convenience software - Support room temperature, temperature control, UV degradation measurement - Data loss prevention function and data processing / aggregation function Applications Evaluation of display luminous reliability, Evaluation of luminous material brightness (relative luminance) lifetime Key components Reliability meter, Element fixture device, Measurement/viewer software, Facility operating PC (Option) UPS, Individual temperature control element fixing device, Constant temperature/high temperature maintenance device