This kit is called CTM(Clinical Virus Transport Medium). CTM is intended for the collection and transport of clinical specimen containing Corona Virus and others. Collected Samples by each Nasopharyngeal Swab and Oropharyngeal Swab can be preserved in One Virus Transport Medium(CTM) simultaneously. -Nasopharyngeal Swab : Tilt the patient's head back slightly to straighten the passage from the front of the nose, and gently inset the swab along the base of the nose(not upwards) until it reaches the nasopharynx-gentle rotation of the swab for a few seconds may be helpful. -Oropharyngeal Swab : Press the tongue and extract the secretion from the back wall of pharynx.
1. Product Overview -EnSave is â??IMPROVER of COMBUSTION EFFICIENCY for INTERNAL COMBUSTION ENGINEâ?? operated by â??CATALYSTâ?? which is created from chemical reaction by rare earth element and precious metal such as platinum, lanthanum, &, etc. -EnSaveâ??s Catalytic Action acts to Enhance the Combustion Efficiency of the engine by leading close to perfect combustion. - As a result, EnSave realizes both â??FUEL SAVING and FUEMS SAVING - â??Double Effectâ?? at the same time, the Remarkable and Innovative Technology is under Patent Pending now. 2. Effectiveness 1) Improving Fuel Efficiency (5~20%): Save fuel cost & Profit-up 2) Engine Power up Higher Combustion Efficiency leads to Engine Power-up 3) Fumes Down: Makes Eco-friendly Green Car 4) Noise & Shaking Down: Driving Fatigue & Stress Down 5) Simple & Easy Installation: Just put EnSave into Air Cleaner Space, No A/S required
1. Sample: Blood (Whole blood, Serum) 2. Measuring Time: 10~15 Minutes 3. Test Principle - Identification of COVID 19 antibody in blood COVID 19 IgG / IgM Rapid Test (WB / Serum / Plasma in human blood) is a fast chromatographic immunoassay for qualitative analysis of IgG and IgM antibodies to COVID 19. 4. Characteristics - Simplicity: No special equipment required and intuitive visual interpretation. - Rapid: Fast sampling with blood at the tip of the finger, results in 10~15 minutes. 5. Main Use - People with symptoms - Suspicious with or without mil d symptoms patient. - It is also used to test people in close contact with infected patients and those in quarantine.
The COVID-19 RT-PCR Peptide Nucleic Acid (PNA) KIT is a real-time reverse transcription (RT)-Polymerase chain reaction (PCR) assay intended for the qualitative detection of nucleic acid from SARS-CoV-2 in respiratory specimens such as nasopharyngeal swabs, oropharyngeal swabs, anterior nasal swabs, midturbinate nasal swabs, bronchoalveolar lavage (BAL), and nasopharyngeal wash/aspirates or nasal aspirates collected from individuals suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. 263a, to perform high complexity tests. Results are for the identification of SARS-CoV-2 RNA. The SARS-CoV-2 RNA is generally detectable in upper respiratory specimens during the acute phase of infection. Positive results are indicative of the presence of SARS-CoV-2 RNA; clinical correlation with patient history and other diagnostic information is necessary to determine patient infection status. Positive results do not rule out a bacterial infection or co-infection with other viruses. The agent detected may not be the definite cause of disease. Laboratories within the United States and its territories are required to report all positive results to the appropriate public health authorities. Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information. The COVID-19 RT-PCR PNA KIT is intended for use by qualified and trained clinical laboratory personnel specifically instructed and trained in the techniques of real-time PCR and in vitro diagnostic procedures. The COVID-19 RT-PCR PNA KIT is only for use under the Food and Drug Administrations Emergency Use Authorization.
Unit Price: USD 15 Target Region: RdRP, E gene, N gene Accuracy: 100% Recommended PCR: CFX96 Real Time PCR System (Bio Rad) DTprime DT-96 QIAGEN Rotor-Gene Q Box Size: Size: W 80 x D 80 x H 65 (mm) Weight: 45g / box Certification: Korea GMP (ISO 13485 2003) European CE
Unit Price: USD 16 Target Region: RdRp, E gene Accuracy: 100% Recommended PCR: Roche Light Cycler 480 Qiagen Rotor-Gene Q plex HRM Applied Biosystems Quantstudio5 Applied Biosystems 7500 Real-Time PCR system Bio-RAD CFX96 Real-Time PCR Detection system Certification: ISO 13485 European CE Health Canada Saudi Arabia FDA
Unit Price: USD 10 Accuracy: 95% Box Size: L 22* W 13* D 7 cm Certificates EN ISO 13485:2016 Adopted Technical Standards IVD directive 98/79/EC, EN ISO13485:2016, EN ISO 14971:2012, EN ISO 18113 1:2011, EN 13975:2003 EN ISO 13612:2002, EN ISO 15223 1:2016, EN ISO 23640:2015 EN ISO 17511:2003
Unit Price: USD 20 Target Region: N gene Recommended PCR: CFX96 Real Time PCR System (Bio Rad) QauntStudio5 Real-time PCR QuantStudio3 Real-time PCR
Nuactor viral RNA extraction kit
FYI, We have FDA emergency use approval / CE / ISO13485:2016 / ISO9001:2015 / GMP / KFDA Expert permit. Genepro COVID-19 Diagnosis Kits / 1Kit for 100 people Our price is CIF based. Genepro COVID-19 Detection Test Kit is a RT-PCR Test, which requires time and other equipment besides the test kit. Specimens are collected using Nasopharyngeal / Oropharyngeal swabs or Sputum. RdRP gene (RNA-dependent RNA polymerase gene) & E gene (envelope protein gene). The running time after RNA extraction is about 90 minutes. For 1 copy/ L, the sensitivity rate is higher than 99%
FYI, We have FDA emergency use approval / CE / ISO13485:2016 / ISO9001:2015 / GMP / KFDA Expert permit. Genepro COVID-19 Diagnosis Kits / 1Kit for 100 people Our price is CIF based. Genepro COVID-19 Detection Test Kit is a RT-PCR Test, which requires time and other equipment besides the test kit. Specimens are collected using Nasopharyngeal / Oropharyngeal swabs or Sputum. RdRP gene (RNA-dependent RNA polymerase gene) & E gene (envelope protein gene). The running time after RNA extraction is about 90 minutes. For 1 copy/ L, the sensitivity rate is higher than 99%
Rapid Test for SARS-CoV-2 antibodies within 15 minutes Available for whole blood, serum or plasma No special equipment or training required Excellent accurate clinical efficacy
Rapid Test for SARS-CoV-2 antibodies within 15 minutes Available for whole blood, serum or plasma No special equipment or training required Excellent accurate clinical efficacy
Product Description : Covid19 test kits Product origin : Korea Payment Terms : Pay By 100% T/T in advance Shipping Terms : after deposit confirm price: Negotiable I Will be waiting for feedback if interested.Communicate through E-mail for faster response. Thanks
Product Description : Covid 19 test kits Product origin : Korea Payment Terms : Pay By 100% T/T in advance Shipping Terms : after deposit confirm price: Negotiable I Will be waiting for feedback if interested. Communicate through whatsapp for faster response. Thanks
Product Description : Covid19 test kits Product origin : Korea Payment Terms : Pay By 100% T/T in advance Shipping Terms : after deposit confirm price: Negotiable I Will be waiting for feedback if interested. Communicate through whatsapp for faster response.
please contact me if you need Korean Rapid/RT-PCR detect Kit (rapid: Genbody, SD biosensor, Wellsbio, Boditech, Bionote, Nanoentek) (RT-PCR: Wellsbio, GeneMatrix, SD Biosensor)
IgG IgM Duo blood 5-10 min 93+% accuracy Made in South Korea
Antigen test kit.
Molecular diagnostics, biochemical diagnostics.