The YH-830 Bi-level device is indicated for treatment of sleep apnea hyponea syndrome in patients weighing more than 66Ib (30kg). It is intended both for home use and hospital use. The water tank is intended for single patient use in the home environment and re-use in a hospital/institutional environment. Maximum inhale pressure 30cmH2O, with separate humidifier (better humidification) ST and target tidal volume mode settings Fast rise time Normal inhalation intensity, respiration rate is 54 times / min, with each exhalation triggering the ventilator perfectly. Good synchronization with big flow Mode: CPAP, S, T, ST, VGPS Trigger adjustment Cycle adjustment Slope adjustment Noise less than 32 dB(A) With YF-01 mask, humidifier and SD card Water tank and power adapter Parameters Package Size 3 CTNS 48.5 32.521.5cm 37 24 17cm(Cart Parts) 90 52.8 21cm(trolly) N.W.(kg) 22 G.W.(kg) 28 Pressure: 4-30 cm H2O
The Y-30T respiratory ventilator comes with a humidifier and provides non-invasive ventilation for patients with respiratory insufficiency. BiPAP demonstrates excellent therapeutic effect for diseases like obstructive sleep apnea-hypopnea syndrome, SOAGG, chronic obstructive pulmonary disease, COPD, interstitial lung disease, ISL, spinal muscular atrophy, CMA, Pickwick syndrome, cystic fibrosis and amyotrophic lateral sclerosis, or ALS. BiPAP synchronizes quickly with the individual characteristics of the patient's body, with increased sensitivity of sensors and automatic adaptability of settings. BiPAP is easy to set up, and allows fast switches from different treatments, regardless of the number of patients and the complexity of the disease. Simple, reliable, sensitive, quickly synchronized with the patient Suitable for home use Non-invasive CPAP, S, S / T, T operating modes IPAP 4-30, EPAP 4-30 8-step inhalation-exhalation triggers Adjustable inhalation-exhalation pressure Inhalation time (0.5-3 seconds) and respiration rate 3.5 "color LCD display; high-quality body and humidifier material Monitoring Vt, Res Rate, Min Vent, Leak. Alarms in all respects 5-step adjustment of the humidifier Display of the key parameters of therapy in the online mode Build quality conforms to German standards ** Specifications Pressure Range: 4-30cm H20 Model number: Y30 Auto on/off: No Noise Level: 3 dB Weight: 1.3kg
Key Specifications/Special Features: Aerospace quality, professional technology, a popular model Easy to take, dampproof, quakeproof and salt fog resistance Invasive, non invasive and manual ventilation in one machine Volume regulation, pressure limit, time switch, demonstrating the strategy of lung protection Inspiration halt, convenient for sucking phlegm and avoiding cross infection Driven mode: pneumatically driven and electrically controlled Three kinds of power supply: A/C, D/C and on vehicle power supply Application: adult & child Ventilation modes Volume control: A/C SIMV A/C + SIGH Manual Ventilation SPONT NIPPV Controlling part Tidal volume (VT): 50ml~1500ml Minute Volume: 0~20L/min I/E Ratio: 1:0.3, 1:0.5, 1:0.7, 1:1, 1:1.5, 1:2, 1:2.5, 1:3, 1:3.5, 1:4 Respiratory rate (f): 4~80bpm Limited pressure: 1kPa ~ 5kPa Trigger sensitivity: 2kPa ~ 2kPa Continuous current: 3 ~ 5LPM Manual inspiration halt: 20s Inhaled oxygen concentration: 48% ~ 100% consecutive adjustment Safety valve pressure limit: 5.1kPa ~ 6kPa Monitoring part LCD display Airway pressure waveform Inhaled tidal volume Minute Volume Total respiratory rate Peak airway pressure Trigger pressure AC/DC indication Could monitor all parameters and waveforms in manual mode Audible and visual alarm part Upper and lower airway pressure limit Power supply failure Low charge of battery Others Power supply: AC220V± 10%, 50Hz± 1Hz, 12V on vehicle power supply Built in battery: provide a more than 2 hour power supply when power off Gas pressure: 0.25~0.6Mpa. Cylinder gas supply can work continuously for 30min. Ventilator compliance: 40 x 10 2 ml/Pa Weight: 22kg Export Carton Dimensions: 60x 40 x54 cm
The Shangrila 510S is a universally used model. Not only for emergency ventilation, but also it is suitable for ideal transport ventilation. The circumstances include on-site emergency treatment, pre-hospital transport, interhospital transport, and even intra-hospital transport. Specification Ventilation Mode: Assist/Control (A/C) Manual Parameter MV: 3~20 L/min (used in 60%), 3~14L/min (used in 100%) Respiratory rate: 10~60bpm I:E ratio: 1:2 FiO2: 60%,100% Trigger sensitivity: Pressure, -3cmH2O Monitoring Pressure values: Paw Alarm: Paw high, O2 supply down Technical Data Gas supply: O2, 0.28~0.6MPa Maximum security pressure: 8kPa Compliance: 4mL/100Pa Noise: 65dB(A) Dimensions (H WD):276 110142mm Weight: 2.4kg Environment Requirement Temperature:-18C~50C (Operation)-20C~55C (Storage) Relative humidity: 5%~95%, non-condensing (Operation) 93% (Storage) Atmospheric pressure: 70~110kPa (Operation), 50~110kPa (Storage)
P30 Portable Non-invasive ventilation P30 is mainly applicable to patients with mild or moderate respiratory failure, no evidence of emergency intubation, relatively stable vital signs, and no contraindication to non-invasive ventilation. It is used for early intervention and assisted withdrawal of respiratory failure. Advantages Small SIze and easy to carry Color LCD display, easy to operate Display and monitor patient clinical usage data in real time Features Low-flow oxygen can be connected for air-oxygen mixing Has VAF target tidal volume function Can be equipped with blood oxygen module Can be equipped with an independent humidifier Configurable trolley Maximum JPAP to 30cmH20 Ventilation mode: CPAP, APAP, S, ST, T, APCV, AutoB 4 work modes: CPAP, S, T, S/T, APCV APCV mode:Assist pressure control ventilation Dynamically monitor the treatment effect Real-time alarm in case of failure Light weight:2.0kg (without trolley) Scope of application Assistant therape of respiratory disease, HD(Pulmonary heart disease), COPD(chronic obstructive pulmonary disease), Motor neurons. Specifications Difference: B-30P Screen: 3.5 Inch color TFT Work mode: CPAP, S/T, S, T, APCV Inspiration Pressure: 4-30cmH20 Inspiration Sensitivity: Auto, 1-6 level Expiration Pressure: 4-25cmH20 VAF function: Yes, Tidal Volume 50-2000ml
Wrap-around design fits snugly to protect you from flying debris, dust, airborne particles and splashes. Scratch resistant Anti-fogging Color: clear Lens material: polycarbonate DEscription : Safety Scratch resistant, anti fogging color clear lens material polycarbonate Quantity : 1,000,000
Product Name: Diesel
The iNSTAXTRACT RNA Extraction kit uses mini spin column technology for isolation and purification of COVID-19 viral total RNA from swab samples in viral transport medium, cell-free fluids such as serum, plasma, body fluid, and cell culture supernatants. SALIENT FEATURES -Gives good results even with low viral load samples -Fast and simple with less preparation time -Open system compatible with any brand of commercial RT-PCR/q-PCR kit -Intact viral RNA and high yield
Product Details: Usage/Application Hospital shelf life 18 months SD BIOLINE Syphilis 3.0 test is a solid phase immunochromatographic assay for the qualitative detection of antibodies of all isotypes (IgG, IgM, IgA) against Treponema pallidum (TP). Specimen: Serum, Plasma, Whole Blood Sample Volume: 10MuL Serum / Plasma and 20MuL Whole blood Recombinant TP, 15kDa, 17kDa antigens used as captures and detectors The optimal choice for mass screening program No need preprocessing and equipments Storage: Room temperature (2-30 degree C) Performance: Sensitivity: 99.3% Specificity: 99.5% One Step Syphilis Antibody Rapid test Ordering Information Cat No. Description Type Pack size 06FK10I50 SD Bioline Device 50 Tests Syphilis 3.0
Product Details: Usage/Application Hospital Results 15 min SD BIOLINE TB Ag MPT64 Rapid is a rapid immune chromatographic identification test for the M. tuberculosis complex. M. tuberculosis has been known to secrete more than 33 different proteins. One of the predominant proteins, MPT64 was found in the culture fluid of only strains of the M. tuberculosis complex. Rapid discrimination between the M. tuberculosis complex and MOTT bacilli Identification of the M. tuberculosis complex in combination with culture systems Sample: Colony, Condensation fluid(Solid cultures) or Liquid cultures Interpretation time: 15minutes Detection limit: 105CFU/ml Ordering Information Cat No. Description Type Pack size 08FK50 SD TB Ag MPT64 Device 25 Test
Product Details: Usage/Application Hospital Tests Kit Filarial antigen Results 10 min The BinaxNOW Filariasis is an in vitro immunodiagnostic test used to detect Wuchereria bancrofti antigen in whole blood, serum, or plasma. The test employs an antibody specific for W. bancrofti. Accurate: Lymphatic filariasis does not always result in clinical symptoms so the most accurate way to diagnosis is using a blood test. Simple: The BinaxNOW Filariasis card test does not require laboratory facilities. Convenient: The test uses finger-prick blood taken at any time of the day without regard to nocturnicity of parasite. Traditionally testing was restricted to the hours of 10 pm and 2 am when the parasite appeared in the patientâ??s blood. Flexible: The test detects filarial antigen in whole blood, serum or plasma. Rapid: The test yields results in 10 minutes.
Product Details: Usage/Application Hospital Results 15-30 min Specimen Whole Blood Test Storage Room Temperature shelf life 24 months The Alere SD BIOLINE Malaria Ag P.f/Pan test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and common Plasmodium lactate dehydrogenase (pLDH) of Plasmodium species in human whole blood. Optimal screening test for P.falciparum and other Plasmodium species Ordering Information Cat No. Description Type Pack size 05FK63I01 SD Malaria Device 1 Test
Product Details: Usage/Application Hospital Time To Result 15 Min Method Rapid Shelf Life 24 Temperature 1-40C The SD BIOLINE Malaria Ag P.f/Pv test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium vivax in human whole blood. Specomen: Whole blood Time to result: 15 -30 minutes Storage: 1-40 degree C for 24 months Performance: Sensitivity: Pf-99.7%, Pv-95.5% Specificity: 99.5 % Optimal screening test for Plasmodium falciparum and Plasmodium vivax Ordering Information Cat No. Description Type Pack size 05FK80I40 SD Malaria Device 40 Tests
We can supply the said coal from Binuang, South Kalimantan on FOB mv terms only. 100% LC at sight from Prime bank. Total Moisture. arb. 6 - 8% Inherent Moisture adb 5 - 7% Ash. adb 10 - 12% Volatile Matter. adb. 40 - 45% Total Sulphur. adb. 0.7%. Calorie Value. arb. 6500 to 6300 HGI. 45 Laycan: will be 25 working days after the LC is active. Minimum 30,000 M/Tons to 50,000 M/Tons.
Fast detection of current Covid-19 condition in 10 Minutes. Suitable for testing large number of of patients. Affordable testing expenses. Certified Quality Standards. Approved by Health Science Authority of Singapore.
Specification: - Gross Calorific Value (ARB) 6300 Kcal/Kg - Total Moisture (ARB) 8.92% - Inherent Moisture (ADB) 5.62% - Sulphur Content (ADB) 0.96% - Ash Content (ADB) 8.70% - Volatile Matter (ADB) 43.33% - Fixed Carbon (ADB) 42.35% - HGI 44 - Size Raw Coal
Coal
We Are Looking For 60,000mt 10pct Rb2 South African Steam Coal For Pakistan Market. Pls Quote Us On Usd Per Mt Cfr Karachi Port, Pakistan.
Bold to the max and permanent to the core, Sharpie Permanent Markers inspire you to transform ordinary surfaces into passionately creative statements. Proudly permanent ink marks on paper, plastic, metal, and most other surfaces Remarkably resilient ink dries quickly and resists both fading and water; AP certified Endlessly versatile fine point is perfect for countless uses in the classroom, office, home, and beyond
We have access to few brands of Convid 19 rapid test IG/G IG/M , PCR types as well. We welcome enquiries. Thank you. Stay Safe & practise social distancing.