A temporary refuge is a place or shelter where personnel will be adequately protected from relevant hazards while they remain on an installation following a major incident, and from where they will have access to the communications, monitoring and control equipment necessary to ensure their personal safety, and from where, if necessary, safe and complete evacuation can be affected. The Temporary Refuge will switch HVAC from fresh air mode to full recirculation mode in case of potential toxic gas intrusion, fire damper closure activated by external gas detectors. The TR will also provide minimum breathable air concentration by air cylinders enough for above 1 hour or more. The Temporary Refuges is located to ensure the safety of personnel during the period of time that covers the call to muster until an incident has been investigated and controlled, or successful evacuation of the installation has been completed. The TR shelter have adequate medical and welfare facilities, as well as emergency communications. The TR shelter is designed for external installation with a supply duct to the TR area interior. The TR shelter control panel is designed to be installed internally within the TR area. When the TR shelter is operational, the shelter is designed as a fail-safe system, i.e. should the shelter sustain damage or an air seal leaks, then clean air will leak out of the shelter rather than contaminated air being drawn in.
Temperature range: -25C° and +25°C Fresh air exchange: adjustable from 0-285 m³/hr Dehumidification Range: 65% - 85% (in chilled mode) Bottom-air delivery Dual temperature settings for chiller/ambient or freezer unit Electronic control panel Flashing strobe beacon in operation when unit powered Data logger Hygienic, easy-to-clean stainless steel interior with shelving Digital electronic controller See-through lockable control panel Double wing door with heavy duty hinges DNV 2.7-1 wire rope sling assemblies 230/110V single phase or 380-480V, 2 phase + E, 50/60Hz supplies Satellite real-time tracking GPS device (ATEX, IECEx, Zone 0)10reefer DNV 2.7-1 / EN12079 temp -18c to +22 degree Including offshore certificate and CSC certificate; Including LR inspection charge on site; Including refrigeration machinery, DAIKIN type marine RU
40' Onshore freezeReefer Containerr container,Carrier RU
TLS intelligent pressurised containers creat a safe area environment for personnel and equipment with built in HVAC and power control systems. All containers are designed and built as per client's specifications and requirements. The containers house our customer s specialist equipment in complete safety. State-of-the art safety monitoring systems are incorporated, including an integrated fire and gas, pressurisation and emergency shutdown system, suitable for zone 1 / zone 2 hazardous areas. TLS is able to integrate data communication networks, fire suppression system, air condition system and other systems to ensure rapid mobilisation and easy hook-up. All pressurised containers are designed, manufactured and certified to the latest DNV 2.7-1, EN 12079 offshore container standards, ATEX, IEC 60079-13 and / or SOLAS standards.
Offshore containers, pressurized cabin, office container, accommodation modules, workshop conatainer, reefer container, mess module, cargo barsket, tank container, open top container, drum basket, mini container, reefer container.Manufacturing