Please click here to check who's online and chat with them.

Find Verified Rapid Test Kits Suppliers, Manufacturers and Wholesalers

Dec-20-17
 
1.Product description
(1)Product name: hCG One Step Pregnancy Test Kit
(2)Specimen: Urine
(3)Format: Strip/cassette/midstream
(4)Specification: 25pcs, 40pcs, or customized
(5)MOQ: 10,000 pcs
(6)Accuracy: > 99%
(7)Storage: 4-30°C
(8)Valid for: 24 months
Jan-16-18
 
A rapid test for the qualitative detection of antibodies (IgG and IgM) to Dengue virus in whole blood, serum, or plasma.
For professional in vitro diagnostic use only.
INTENDED USE
The Dengue IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to Dengue virus in human whole blood, serum, or plasma as an aid in the diagnosis of primary and secondary Dengue infections.

DIRECTIONS FOR USE
Allow the test device, specimen, buffer, and/or controls to reach room temperature (1530°C) prior to testing.
1.Bring the pouch to room temperature before opening. Remove the test device from the sealed pouch and use it as soon as possible.
2.Place the test device on a clean and level surface.
For Serum or Plasma Specimens:
Hold the dropper vertically, draw the specimen up to the Fill Line (approximately 5 μL), and transfer the specimen to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 L) and start the timer. See illustration below. Avoid trapping air bubbles in the specimen well (S).
For Whole Blood (Venipuncture/Fingerstick) Specimens:
To use a dropper: Hold the dropper vertically, draw the specimen 0.5-1 cm above the Fill Line, and transfer 1 drop of whole blood (approximately 10 µL) to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 uL) and start the timer. See illustration below.
To use a micropipette: Pipet and dispense 10 µL of whole blood to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 µL) and start the timer. See illustration below.
3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
Jan-16-18
 
A rapid test for the qualitative detection of circulating antigens of Plasmodium falciparum, Plasmodium vivax, Plasmodium ovale, Plasmodium malariae in whole blood.
For professional in vitro diagnostic use only.

Sensitivity
The Malaria P.f/ Pan Rapid Test Device (Whole Blood) has been tested with thin or thick microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f/ Pan Rapid Test Device (Whole Blood) is >99.9% relative to microscopy.
For Pan:
Relative Sensitivity: >99.9% (158/158) (97.6%100.0%)*
For P.f:
Relative Sensitivity: >99.9% (53/53) (93%100.0%)*
Specificity
The Malaria P.f/ Pan Rapid Test Device (Whole Blood) uses highly specific antibodies for Malaria P.f/ Pan antigens in whole blood. The results show that the specificity of the Malaria P.f/ Pan. Rapid Test Device (Whole Blood) is over 99.0% relative to microscopy.
Relative Specificity: >99.0% (324/327)(97.3%99.8%)*
Accuracy: >99.4%(535/538)(98.3%99.8%)*
* 95% Confidence Interval

Total Results211327538
Note: The comparison for Pan line has been only done with blood specimens positive with Plasmodium vivax specimen. The claims for Pan lines are based on scientific findings that Pan-malarial Aldolase is found in other malarial parasites including Plasmodium ovale and Plasmodium malariae.
Jan-16-18
 
Troponin I (CTnI) One Step Rapid Test Kit
(Whole blood/serum/plasma)
Product description

Product name:
CTnI One Step Troponin I Rapid Test Kit
Specification:
Lateral-flow Immunofluorescence Chromatographic Assay 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized
Type:
Cassette
MOQ:
10,000 PCS
Analytical Range:
1.0~50ng/ml (Whole Blood); 0.1~50ng/ml (Serum/Plasma)
Specimen:
Human serum/plasma/whole blood
Manufacturer:
Hangzhou Laihe Biotech Co., Ltd.
2.Clinical significance
(1)Diagnosis of various chest pain
(2)Foundation of ACS diagnosis and risk stratification
(3)Best markers for ACS prognosis
(4)An aid in the diagnosis of myocardial infarction (injury)
(5)Can improve clinical, economic and operational outcomes
Jan-16-18
 
In One Cup Cup Multi-drug One Step 2-15 Drug Test Simple Cup (Urine) CE Qualified (MOP/MET/KET/AMP/BAR/BUP/BZO/COC/COT/MDMA/THC/MTD/OPI/PCP/TCA)
1709 Rapid Test Kits Suppliers
Short on time? Let Rapid Test Kits sellers contact you.
Feb-16-23
Supplier From India
Sep-30-22
Supplier From Navi Mumbai, Maharashtra, India
Jan-27-17
Supplier From Cheonan-si, Chungnam, South Korea (Republic Of Korea)
Apr-10-17
Supplier From Hangzhou, ZheJiang, China
VERIFIED
May-30-21
Supplier From Beijing, China
Feb-28-25
Supplier From Mumbai, Maharashtra, India
May-22-20
Supplier From South Korea (Republic Of Korea)
 
I am representing SD Biosensor from South Korea that manufactures US FDA EUA approved Standard M nCo V Real-Time Detection Kit (COVID Testing kit). We have received US FDA EUA approval to export Covid 19 detection kit in April and can directly export from Korea.
SD Biosensor is one of the few companies that has received US FDA approvals and have already sold 1.5 million testing units to US government (Based on US government reaching out to South Korea Government for help with procuring Covid Testing kits).
I'm currently in Seoul, South Korea but I'm a US citizen helping SD Biosensor as an agent to help buyers procure these testing kits. This company has capability to manufacture over 600,000 testing units a day and have enough supplies readily available for an immediate export.
Please email me at Jinsoo.park@att.net to receive US FDA EUA Approval and product information. rapid test kits which are not FDA approved are in the low to mid $20 range and the price for FDA EUA approved standard test kits are around high $20s to low $30s and depending on the contract length and quantity we have some room for negotiation. Also these kits have to be refrigerated shipped so there will be some additional cost for this.
Sep-09-21
Supplier From Changsha, Hunan, China
Feb-17-22
 
Antigen test kits

Allocation Available
10 Million pcs/month

MOQ : 2.5M Pcs

$5.80 including (CIF Via AIR)

SOP:

ICPO/POF
Commercial Invoice/SPA/POP
SBLC
AWB/SGS/Delivery
SBLC Released
Dec-15-21
 
Types of Transport Systems Suitable for Test of COVID-19
The formula contains special ingredients to maintain and store viruses for a longer time. It helps viruses to maintain its viability.
Flocked Swab Suitable for Sample Collection of Different Types of Virus Specimens
Flocked swab can uptake and release sample into liquid medium better than rayon swab.
Room Temperature Storage up to 96 Hours
Good Virus vitality and infectivity after stored under room temperature 96 hours
Jun-23-21
Supplier From India
Jun-16-21
Supplier From VISAKHAPATNAM, Andhra Pradesh, India
May-28-21
Supplier From India
Mar-25-21
Supplier From India
Mar-26-21
1709 Rapid Test Kits Suppliers
Short on time? Let Rapid Test Kits sellers contact you.
See what buyers and suppliers are discussing in Rapid Test Kits import export community