1. Principle This kit is based on the specific reaction of antibody-antigen and immunochromatography. β-lactam and tetracyclines antibiotics in the sample compete for the antibody with the antigen coated on the membrane of the test strip. Then after a color reaction, the result can be observed. 2. Applications This kit is used for rapid qualitative analysis of β-lactam and tetracyclines in milk sample.
Medical disposable rapid test kits.
Veterinary rapid test kits, animal rapid test kits,.
3 ply mask. blue fda registered nitrle gloves covid 19 rapid test kits made in usa medica supply.
Surgical instruments, nitrile gloves, covid rapid test kits, ventilators, and other various ppe..
Veterinary rapid test kits.
Veterinary rapid test kits.
Rapid test kit, ELISA kit and CLIA kit and food safety.
It's special designed to detect the Aflatoxin M1 in raw, commingled cow milk at or below established tolerance and/or safe levels. The kit is only for screening test, positive result should be further confirmed with other method.
H-fabp fast test kit (immunofluorescence assay) is intended for use together with getein1100 immunofluorescence quantitative analyzer (getein1100) or getein1600 immunofluorescence quantitative analyzer (getein1600) to quantitatively determine the concentrations of h-fabp in human serum, plasma, or whole blood specimens in point-of care and laboratory settings. H-fabp fast test kit (immunofluorescence assay) is intended for in vitro quantitative determination of heart-type fatty acid binding protein (h-fabp) in serum, plasma or whole blood. This test is used in the early diagnosis of ami and pulmonary embolism, and monitoring of chronic heart failure.
The cardiac troponin i fast test kit (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunochromatogrphy to determine ctni in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify ctni specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of ctni. Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of ctni is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for NT-proBNP (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine NT-proBNP in human serum, plasma, or whole blood specimens. One monoclonal antibody and one polyclonal antibody are employed to identify NT-proBNP specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of NT-proBNP. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of NT-proBNP is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for PCT (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine PCT in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify PCT specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of PCT. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of PCT is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for NAGL (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine NGAL in human urine specimen. Monoclonal antibody and polyclonal antibody are employed to identify NGAL specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of NGAL. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of NGAL is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for B2-MG (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine B2-MG in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify B2-MG specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of B2-MG. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of B2-MG is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for mAlb (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine mAlb in human urine specimen. Polyclonal antibody and recombinant antigen are employed to identify mAlb specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of mAlb. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of mAlb is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
In the past two months, China was infected by the COVID-19( Noval Coronavirus), in order to diagnose the diseases earlier, Encode team work hard and finally develop the COVID-19 IgM/IgG rapid test kit, which clinical positive detection rate is over 90%.
MADE IN KOREA!! for more detail, Email US
Animal diagnostic rapid test kits, veterinary hospital equipments.
Lab supplies and rapid test kits..