Fiber-optic-cables.
Wire harness.
Xray, reflow oven, screen printer, conveyor, ultrasonic cleaner, dispenser, furnace, chambers, electronics, SMT, semiconductor.
UPS , transformers & computer parts.
Reseller of parts & accessories of all types of household appliances including refrigeration & air conditioning jobs, electrical, civil, plumbing, & other system's works, electronics as i.t. related like computers, mobile phones, & other gadgets, sound system, motor vehicles, articles, equipment, hardware, paints, glass, and goods in specialized stores..
Infusion Pump.
Transformers..
Fiber Optical Cables..
Wire manager, server rack, telephone terminal cabinet, open-bay rack, cable tray, cable ladder, enclosed circuit breaker, panel board, switchgear, camera pole & bracket, information kiosk, gondola, locker, file drawer, Murphy beds.Shipping
Size: FY400(48X48 mm), FY600(96X48mm), FY700(72X72mm), FY800(48X96mm), FY900(96X96mm) Supply voltage: AC 85-265V, DC 24V Frequency: 50/60 Hz Memory: Non-volatile memory E PROM Input: Universal Thermocouple - type K, J, R, S, B, E, N,T , W5Re/W26Re RTD - DPT100, JPT100, JPT50 mA dc - 4-20mA, 0-20mA voltage Dc - 0-1V, 0-5V, 0-10V, 1-5V, 2-10V, -10-10mV 0-10 mV, 0-50mV, 10-50mV DP position: 0000, 000.0, 00.00, 0.000 (available for mA or Voltage dc input). Output: Relay: SPST or SPDT Type 3A, 220V electrical life 100,000 times or more(under rated load) Voltage Pulse: for SSR, On: 24V Off: 0V maximun load current 20mA mA DC: 4-20 mA, 0-20 mA maximum load resistance 560 ohms Voltage DC: 0-5V, 0-10V, 1-5V, 2-10V Maximum load current 20mA Alarm: SPST or SPDT type 3A, 220V electrical life 100,000 times or more (under the rated load) Control Algorithms: PID, P, PI, PD On/Off (P=0), Fuzzy PID range P= 0-200%, I=0-3600 secs, D=0-900 Secs Isolation: Output terminal ( control output, alarm, transmission) and input terminal are isolated separately Operating Temperature: 0-50 deg C Humidity: 20-90% RH Optional Specs RAMP/SOAK program : 2 patterns with 8 segments each, the 2 patterns can be linked together as 16 segments use Output 2: Relay: SPST or SPDT Type 3A, 220V electrical life 100,000 times or more(under rated load) Voltage Pulse: for SSR, On: 24V Off: 0V maximun load current 20mA mA DC: 4-20 mA, 0-20 mA maximum load resistance 560 ohms Voltage DC: 0-5V, 0-10V, 1-5V, 2-10V Maximum load current 20mA Alarms capable up to 3 alarms Heater Break Alarm: Display range of Heater Current: 0.0-99.9A Accuracy 1%FS Included CT; SC_80_T (5.8mm dia, 0.0-80.0A) or SC_100 12mm Dia, 0.0-99.9A) Alarm Relay AL1 Transmission: Available for PV and SV transmission mA DC: 4-20 mA, 0-20 mA maximum load resistance 560 ohms Voltage DC: 0-5V, 0-10v, 1-5V, 2-10V maximum load current 20mA Remote SV Input: 4-20mA, 0-20mA 0-5V 0-10V, 1-5V, 2-10V are available Communication: Protocol: MODBUS RTU, MODBUS ASCII, TAIE interface: RS232, RS485, TTL Baudrate: 38400, 19200, 9600, 4800, 2400 bps. 8 bit, start bit: 1bit, Parity : ODD or even stop bit: 1 or 2 bit WaterProof/Dustprof: IP65.
Fire Detection And Alarm System, Preventive Maintenance, Testing And Commissioning And Installation, Fire Supplies And Products..
Used Generator Set & Porklift.
Biomass, Solar and Waste to Energy Power Plants .
Universal testing machines, weatherometers, metrological equipment.
Manufacturing metal fabrication including jig and fixture, graphite and ceramic fabrication, wire harness blades, swage die.
Industrial motor parts and shipmotor parts.
PCB board and IC chips.Contract
Intermodal genset, container, and chassis.
Cosmetic products, appliances.
Used generator set & porklift.