Type:THB/10-I & THB/15-I Cylinder Volume:2.2L /3L Working Pressure MPa:21 Duration of usage(min):â?¥10 / â?¥15 Service-life or storage time(year): 15 ITEM TIME By sea 15-30days By air 3-5days By express company such as DHL, UPS, FEDEX, SF or as your demand 5-7days
Features: * The boosting pipe is compatible with standard 1.80ML local anesthetic and two models of syringe needles (British system and metric system). It is mainly used for local anesthesia injection of oral cavity. * There is no pipeline or other consumables, which may save the anesthetic and save the clinical cost. * There is no foot switch, just operation via pen holding; it can be operated simply while the first finger touches the sensor. * The unique design combines the pen holding type with the one-button operation perfectly, brings easier operation for doctors. * Low noise with melodious music. * The LCD display screen shows the operational process and dosage visually. * Non-contact of induction charging.
Manual FUE Hair Transplant Punch available in custom designs
FUE Hair Transplant Punch available in all size
ENV-40-DO Dissolved Oxygen Probe Operating principle A galvanic dissolved oxygen probe consists of a polyethylene membrane, an anode bathed in an electrolyte and a cathode. Oxygen molecules defuse through the probes membrane at a constant rate (without the membrane the reaction happens to quickly). Once the oxygen molecules have crossed the membrane they are reduced at the cathode and a small voltage is produced. If no oxygen molecules are present, the probe will output 0 mV. As the oxygen increases so does the mV output from the probe. Each probe will output a different voltage in the presence of oxygen. The only thing that is constant is that 0mV = 0 Oxygen. (A galvanic dissolved oxygen probe can also be used to detect the Oxygen content in gases). This Dissolved Oxygen probe can be fully submerged in fresh or salt water, up to the BNC connector indefinitely. ENV-40-DO Dissolved Oxygen Probe Typical Applications * Standard Lab use * Field use * Hydroponics * Fish keeping * Wine making * Food Safe * Environmental monitoring ENV-40-DO Dissolved Oxygen Probe Specifications * Reads: Dissolved Oxygen * Range: 0 - 100 mg/L * Response time: ~0.3 mg/L/per sec * Max pressure: 3,447 kPa (500 PSI) * Max depth: 343 meters (1,125 ft) * Temperature range: 1 - 50'C * Weight: 52 grams * Dimensions: 16.5mm x 114mm (0.5" x 4.48")
Electrode, 22mmx22mmx3pcs, Prewired Neonatal, Cloth 1.Gentle for neonatal patients with a conductive adhesive hydrogel andbreathable stretchable material. 2.Prewired for added convenience.
1.Complete line of pressure infusers is designed for invasive blood pressure monitoring, rapid infusion of liquid, and for use with auto transfusion devices. 2.Disposable infusors are made from white nylon with clear sleeve material for easy visualization of fluid. 3.Piston-type gauge. 4.Single patient use. "
1.Simple and resaonable design, easy and fast remove. 2.Remove both of our regular and wider size skin staples. 3.Save handle time and remove with no pain. 4.Sterile.
1.Disposable skin stapler includes a counter to indicate the exact number of staples used throughout the procedure. 2.Contains 35 wide medical grade stainless steel staples. 3.The handle design allows for easy application and smooth actuate force. 4.Sterile.
1.Superior conductance and adhesive; 2. Avoid electric burning, prevent cross infection; 3.Soft, Non-vytotoxic, Non-resistance; 4.Without Stimulus and sensitivity; 5. Single use only.
1.Disposable skin stapler includes a counter to indicate the exact number of staples used throughout the procedure. 2.Contains 35 regular medical grade stainless steel staples. 3.The handle design allows for easy application and smooth actuate force. 4.Sterile.
1.Single squeeze allows for easy activation of packs offering immediate relief to injured area; 2.Non-woven lining helps prevent the pack from sweating and can be placed directly on the skin; 3.Flexible material conforms to body contours 4.Reman cold 15-40 mints and achieves a low temperature of 25 F; 5.Ideal for minor sprains,burns, nosebleeds and headaches, reduces swelling.
1. Single squeeze allows for easy activation of packs offering immediate relief to injured area 2.Non-woven lining helps prevent the pack from sweating and can be placed directly on the skin; 3.Reman hot 15-30 mints and achieves a high temperature of 130 F 4.Flexible material conforms to body contours 5.Ideal for applications such as neck pain, arthritis back injuries and shoulder injuries�?Treat muscle strains, aches, tension and cramps.
Electrode, ECG, 42mmx50mm, Adult, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
used medical equipment ambulance
Aflatoxin B1 ELISA Test Kit is a competitive enzyme immunoassay for the quantitative analysis of Aflatoxin B1 in cereals, meat/fish, feed, milk,milk powder ,oils,peanuts and pistachios .The unique features of the kit are: High recovery (80-105%),rapid(10-40minutes), cost-effective extraction methods. High sensitivity (0.05 ng/g or ppb). High reproducibility. A quick ELISA assay (less than 2 hours regardless of number of samples). color box
REAGENFumonisin ELISA Test Kit is a competitive enzyme immunoassay for the quantitative analysis of Fumonisin in cereals, dried meat/fish, feed, milk and seed . The unique features of the kit are: High recovery (80-105%),rapid(10-20minutes), cost-effective extraction methods. High sensitivity (1 ng/g or ppb). High reproducibility. A quick ELISA assay (less than 1 hours regardless of number of samples). Procedure Overview The method is based on a competitive colorimetric ELISA assay. The toxin of interest has been coated in the plate wells. During the analysis, sample is added along with the primary antibody specific for the target toxin and enzyme-conjugate. If the target is present in the sample, it will compete for the antibody, thereby preventing the antibody from binding to the toxin attached to the well. The enzyme-conjugate, will bined with the primary antibody that is complexed to the toxin coated on the plate wells. The resulting color intensity, after addition of substrate, has an inverse relationship with the target concentration in the sample. Sensitivity Sample TypeDetection Limit (ng/g or ppb) Meat/fish/sereal/feed/seed100 Milk10
Fop-m260 fiber medical pressure sensor application Cardiovascular: lv pressure, arterial bp Pharmacology: drug and fluid injection Neurosciences: intracranial pressure Spine - intradiscal pressure Bone - intramedullary pressure Urology - bladder/ureter pressure Mri rfi gating - arterial blood pressure or lv pres-sure for image gating Respiratory / pulmonology Otorhinolaryngology: inner ear pressure Ophthalmology: intraocular pressure Gastro intestinal Fop-m260 fiber medical pressure sensor specifications Pressure range: -300mmhg to 300mmhg Resolution: 0.1mmhg System accuracy: 3mmhg Zero thermal effect:
640mA digital radiography Xray Equipment PLD7200B Usages of Cheap Mobile Digital X Ray System PLD7200B This digital radiographic machine is available for medical teaching, research, medical units for X-ray spot film gastrointestinal photography, remote compartment, and other traumatic perspective X-ray photography and other routine check. The digital x ray machine/x ray machine for sales can be apply to the esophagus, chest, stomach, abdomen, limbs for fluoroscopy and spot film photography. Features of HF radiography X-ray Equipment PLD7200Bz 1.Combined with PLD7200A for double-tube DRF system. 2.One-step workstation from registration to documentation can easily follow the clinical workflow. 3.DICOM 3.0 interface permits to connect PACS network & dry film printer in hospital. 4.Compact,floor-mounted,U-arm design,fits into smaller rooms without the need of ceiling support structures,and can be installed fast.
mega pixels X-ray System gastrointestional PLD8600 Feature of X-ray Radiography System for Medical Diagnostic PLD8600: 1.Dual channels, Photochemical method and electrochemical method. 2.Calibration with memo chip card,make sure accuracy of test result. 3.Automatic storage of the latest 100 results for each project,check it at any time by ourselves,able to clearly know the physical condition. 4.Using Micro USB to connect with computer,to make data communication and lithium batteries charging. 5.Wireless connect with mobile phones via Bluetooth.