Pc polished, sm, sx, il45db, lszh 3.0mm, 1mtr. Each patch cord be packed in individual poly bag.
Features: Suitable for the protection of fiber cables, the scope of application includes aerial, underground, pipeline, and hand hole Fixed and sealed by insert plates and bolts Standard splice trays with single tray access and up to 192 fibers splicing Up to six inlet/outlet ports, configured with one set plastic seal fittings Adopts the turnover structure, convenient for fixing sleeve, winding fiber cable, enlarging and repairing High quality PC material Easy operation Specifications: Housing dimensions (L x W x H): 450 x 216 x 160mm Cable inlets/outlets: six pieces Diameters of cable inlets/outlets: ª+23 (2), ª+20 (2), and ª+16mm (2) Splice trays available: 12 and 24 cores Number of trays: one to eight pieces Splice capacities: 12 to 192 cores
High quality zirconia ferrules PVC and LSZH cables available Low insertion loss and high return loss Good exchangeability and repeatability Conform to ISO9001:2008,ROHS,IEC,Telcordia GR-326-CORE Standard. Application : Fiber Optic Telecommunications CATV,CCTV ,LAN Network FTTH (Fiber To The Home) High speed transmission systems Kington packaging:30pcs per carton, 1pcs per bag
High quality zirconia ferrules PVC and LSZH cables available Low insertion loss and high return loss Good exchangeability and repeatability Conform to ISO9001:2008,ROHS,IEC,Telcordia GR-326-CORE Standard. Application : Fiber Optic Telecommunications CATV,CCTV ,LAN Network FTTH (Fiber To The Home) High speed transmission systems Kington export standard packaging
Optical fiber cables
PVC Sheathed armoured power cable The product not only has good electric capability, but also has good chemical stabilization, simple structure, easy to use, and the laying of cable do not be limited by the fall. It is widely used at the transformer circuit which rated voltage is 6000V or under. The product is produced against IEC60502 and IEC60331, and the product can be produced against the standard of BS, DIN, and the standard required by the clients. 1. The long-term permissible operation temperature of the conductor shall not be higher than 70. 2. The max temperature of the conductor of cable should less then 160 when short circuit. (less then 5 second). 3. The cable is not limited by drop in level when being laid, and the environment temperature shall not be lower than 0. 4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardance. 5. Light weight, perfect bending properties, installed and maintained easily and conveniently. 6. Rated voltage: 0.6/1kV, 3.6/6kV. 7. Number of cores: One, two, three, four, five. Drum
Optical cable Application: CATV Test equipment Metro Applications Active device termination Local Area Networks (LANs) Data processing networks Premise installations
The coloring fibers are positioned in a central loose tube. The PSP is longitudinal covering. Parallel steel wire is inside the PE sheath. Between steel strip and loose tube is filled with a water-blocking compound. Characteristics: Good mechanical and temperature resistant performance. Crush resistance, water blocking and flexibility Geometrical Characteristics: Number of Fibers 2-12 Cable Diameter (mm) 9.8 Cable Weight (kg/km) 110 Mechanical Characteristics: Max Load (N) Long Term 600 Short Term 1500 Crush Resistance (N/100mm) Long Term 300 Short Term 1000 Bending Radius (MM) Dynamic 100 Static 200 Fiber Cladding: Fiber Type (core/cladding dimension) 8.3/125, 50/125, 62.5/125 Transmission Characteristics: SMF 50/125 62.5/125 1310/1550(nm) 850/1300(nm) 850/1300(nm) Max. Attenuation (dB/km) 0.45/0.30 3.5/1.5 3.5/1.5 AVG. Attenuation (dB/km) 0.40/0.25 3.0/1.0 3.0/1.0 Min. Bandwidth (MHz/km) 400/400 160/500 Environmental Characteristics: Storage/Operating Temperature -40íµí½+70íµ
XLPE insulated high voltage power cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower, and also used for Subway,Power station,Factory and Mine.It can be installed underground, in pipe, in trench or in tunnel. XLPE Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
Introduction: The mini dp to vga signal format converter seamlessly connect next generation displayport based macbook, macbook pro, or macbook air with a mini displayport to high definition displays. Mini displayport offers a unified, scalable, and cost effective interface for embedded and external display applications. It not only has an elegant appearance with the white color but also brings much convenience with its small size. It offers solutions for digital entertainment center, hdtv retail and show site, hdtv, stb, dvd and projector factory, noise space and security concerns, data center control, information distribution, conference room presentation, school and corporate training environments. Features: This dp to vga converter has many features that enable it to perform in a superior manner. Among those features you will find: Display port version 1.1 compatible Allows for advanced features that many newer displayport devices can support like deeper color (up to 36 bit) and x.V. Color Slim design Allows you to install the unit is a small space, such as inside an a/v stand High-grade design Gives the adapter the capability to process a large amount of displayport data signals accurately. Built-in shield structure Eliminates exogenous influence for stable signal transmission Simply control Allows for user plug & play, install the adapter to any hdmi monitors from apply mac machine. Half-transparent blister package, good for retailing
Production The td1827 optical fiber identifier is a low cost. Portable instrument designed to detect optical signals without disrupting traffic. During maintenance, installations, rerouting or restorations, its often necessary to isolate a specific fiber. By inserting the fiber into its adapter head, it can identify sm optical fibers without any damage by detecting the optical signals being transmitted through them so as to avoid the opening of the fiber at the spice point for identification, and thus avoids the interruption of the service .In the presence of traffic, the intermittently audible tone is activated. The td1827 optical fiber identifier also aows relative core power display and identification of the 270hz, 1khz and 2khz frequencies. When they are used to detect the frequency, the continuously audible tone is activated. There are four types of adapter heads available: 0.25, 0.9, 2.0 and 3.0. The td1827 optical fiber identifier is powered by a 9v alkaline battery. Efficiently identifies the traffic direction and frequency tone (270hz, 1khz, 2khz) without any damage of the fibers. Displays the core power of the fibers (-50~+0dbm) Low bending loss and highly efficient output Easy-to-replace adaptors (0.25, 0.9, 2.0, 3.0 to match various optical cables) Mechanical damp design of adapter heads to ensure the fiber without damage. Operation design, easy-to-sue Application maintenance in telecom maintenance catv test lab of optical fibers
GEMSCAB cables are made of EC grade Aluminium or Copper, high quality PVC/XLPE insulating and sheating compounds and ISI marked armour materials. GEMSCAB manufacture cables as per relevant National and International Standards and as per customer specification. Weight
Our Strength: Highest standard of quality and services, prompt delivery and competitive pricings.
XLPE insulated power cable is used to transmit power on the power tansmission and distribution of AC,rated voltage 35kv or lower.Incompatison with PVC insulation cable,It boasts not only excellent electric character,mechanical chatacter,heat and agingresistant character,environmental stress-resistant chatacter and chemical corrosionresistant chatacter,but simplw structure,light weight,no restiction by laying drop,and hight temperature allowance for long-term working as well. Executive standard 1)GB/T12706.1-2002(Equivalent IEC 60502) Rated voltage 1kv (Um=1.2kv)and power cable 2)GB/T12706.2-2002(Eqquivalent IEC60502-2)Rated voltage6 kvUm=7.2kv and Um=36kv power cable 3)G/BT12706.3(VOLTAGE Grade Overtep IEC 60502-2) Rated Voltage3.5V Um=40.5kv and power cable. Working consitions: 1) This maximum working temperatuie of thr conductor temperature is +90. During having a short (lasting less than 5 seconds )the maximum temperature of the cable conductor shall not be above +250 Environment temperture should be no lower than+0 for laying the cable. 2) Bending radius allowance of the cable: Single core cable:No steel tape cable 20D,steel tape cable 15D Cores cabel: No steel tape cable 15D steel tape cable 12D Notes: D ptactical esternal diameter of cable. Wooden drums
CU conductor PE insulation Twisted electrical wire belong to the series of laying electrical wire,which is mainly suitable for laying at the fixed places.It is widely used as lighting,connectors of drive, electric equipments,instrument and telecommunication equipments.The rated voltage is 450/750V(U0/U) or below.Part of the plastic wires are used at the equipment with AC rated voltage up to 300/300V . Electric wire is usually PVC insulated wire.This system include the below types: BV,BV-90,BVR, BVV,BLVV,BVVB,BLVVB,RVB,RVS,RVV BV Copper (aluminum) conductor PVC insulated w BLValuminum) conductor PVC insulated wires BVR Copper conductor PVC insulated flexible wires)* Copper (aluminum) conductor PVC insulated PVC sheathed round wires * Copper (aluminum) conductor PVC insulated PVC sheathed flat wires * Copper conductor PVC insulated flat flexible connectors * Copper conductor PVC insulated PVC sheathed round flexible connectors* Sizes: 0.5-185mm2* Standard: GB Standard and IEC Standard. GB 5023.11997450/750V or below PVC insulated electric wires,JB 8734.15-1998450/750V or under PVC insulated cables,electric wires and flexible wiresand Q/ZEL 02-2002Piastic insulated electric wires and cables.GB 5023.17-1997 is identical to IEC227,and type are same as the stipulation of IEC,technical specification is just the same,and more we have extended the range of the type to fit for the requipment of the consumers. We can also produce as per the other special requirements Coil
SY Control Flexible Cables: Plain annealed copper of class 5, special flexible PVC insulation and inner sheath. Galvanized steel wire braiding, special transparent PVC sheath. Core identification: Black cores with white number printed. Version G: One Y/G earth core; Version X without it.
Mining cable
SY Control Flexible Cables: Plain annealed copper of class 5, special flexible PVC insulation and inner sheath; Galvanized steel wire braiding, special transparent PVC sheath. Core identification: Black cores with white number printed. Version G: One Y/G earth core; Version X without it.
Flat cable
LVDS cable, LVDS tv cable Copper conductor Rohs compliance Application:tv, pc, printer Lvds cable, lvds tv cable Copper conductor Rohs compliance Application:tv, pc, printer Specification: Lvds cable Lvds cable Pvc shielding Od:0.5mm~0.6mm Copper conducter Application:tvú¼computer or other home applications. Certificate: rohs Lehgth/color.Oem Packing: Polybag or customized package