RELATED PRODUCTS TC KCC500 TC KCC900 TC KCCX01 TC KCCX03 TC KCCX10 TC KCCX30 TC-KCCX50 TC-KIOL02 TC-KIOL05 TC-KIOL10 TC-KSM003 TC-MC1BNC TC-MC2BNC TC-MC3BNC TC-MC5BNC TC-MC6BNC TC-MDP081 TC-OAH061 TC-OAV061 TC-OAV081 TC-ODA161 TC-ODD321 TC-ODJ161 TC-ODK161
Isolator switch (1)inh-100 isolator switch The items can switch on, load and break the current under normal conditions, using as switch disconnectors. The items comply with iec60947-3 & gb14048.3. Rated voltage: 230/400v Rated current: 40, 63, 80, 100a Pole number: 1, 2, 3, 4 (2)it10-100 isolator switch The items can switch on, load and break the current under normal conditions, using as switch disconnectors. The items comply with iec60947-3 & gb14048.3. Rated voltage: 230/400v Rated current: 100a Pole number: 2 Zhejiang inte industrial electric co., ltd. Was founded in 1984 and is iso 9001: 2000 certified. We mainly manufacture circuit breaker, thermal protector, thermostat and counter etc. Electrical and electronic equipments. Some of our products have got ccc, ul, vde, ce, saso approval. Please feel free to contact us your interest. Leave factory packing
Product description Main switch isolated switch Rated current in (a): 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 Poles:1p, 2p, 3p, 4p Product specification/models Model: ebs1g isolated switch Standard: iec 60947-3 Rated current in (a): 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 Rated voltage ue (v):230/400 Poles:1p, 2p, 3p, 4p Rated insulation voltage ui (v): 690 Rated impulse withstand voltage (v): 4000 Utilization catelogry: ac-22 a Rated breaking capacity: 6ka Rated frequency:50/60hz Degree of protection: ip20 Mechanical life: 8500 Electrical life: 4000 Connection capacity ( isolated switch ): Type of terminal: lug type and pin type Cables up to 50mm2 Mount: on 35mm din rail Standard export carton
Hgl-125a~630a, the load isolation switch is suitable for the on and off electric circuit or electric insulation. Over 1.000a are only suitable for electric insulation. 1. Products with observation windows can be providing according to the demand to observe directly the on and off state of contact. 2. The products have three poles, four poles, and (three poles+on and off neural pole). 3. Two sets of auxiliary contacts can be assembled according to the demand. 4. Mechanical property and electric property correspond to the mechanical property and electric property of hgl-125a~1600a
Standard: IEC/EN60947-3 GB/T14048.3 Rated working current (In): 32-125A Rated working voltage (Ue): AC 230/400V The number of poles: 1P/2P/3P/4P Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): AC 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 8000/1500 Times
Standard: IEC/EN60947-3 GB/T14048.3 Rated working current (In): 32-125A Rated working voltage( Ue): AC 230/400V The number of poles: 1P/2P/3P/4P Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): AC 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 8000/1500 Times
Standard: IEC/EN60947-3 GB/T14048.3 Rated working current (In): 32-125A Rated working voltage (Ue): AC 230/400V The number of poles: 1P/2P/3P/4P Rated operating frequency 50/60Hz Rated insulation voltage Ui AC 500V Rated impulse withstand voltage( Uimp): 4kV Mechanical/electrical life: 8000/1500 Times
Standard: IEC/EN60947-3 GB/T14048.3 Rated working current (In): 32-125A Rated working voltage (Ue): AC 230/400V The number of poles: 1P/2P/3P/4P Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): AC 500V Rated impulse withstand voltage( Uimp): 4kV Mechanical/electrical life: 8000/1500 Times
Standard: IEC/EN60947-3 GB/T14048.3 Rated working current (In): 32-125A Rated working voltage (Ue): AC 230/400V The number of poles: 1P/2P/3P/4P Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): AC 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 8000/1500 Times
The product is used in solar system,the voltage can reach 1500VDC;the mechanism of the product move fast, breaking the contact quickly;and the category is DC21B. The switch has small volume,short arc extinguishing time,multiple contacts operating at the same time and other advantages.It has 1000VDC and 1200VDC specifications.The 1000VDC products can be used in solar system with rated voltage less than 1000 and below,rated current less than 32A;The 1200VDC products can be used in photovoltaic system with rated voltage 1200v or below, rated current 26A or below. The isolator switch have 2P,4P,6P,8P four specification, 2P can be used in a set of system loops;4P can be used in two sets of system loops,6P can be used in 3 sets of system loops,8P can be used in 4 sets of system loops.
Artistic electric switch
We can provide designer modular electrical switches for house , apartments , domestic buildings, institutions etc with 20 year replacement guarantee for switches and plates , 2 year for fan regulators and electronic devices
Approvals:SAA,CB,CE Certified to AS/NZS 3947.3,IEC/EN60947-3 Fix Neutral and Earth bars included Dual 25mm screwed conduit entries on top and bottom Utilization Category:AC22A/AC23A IP66 Rating on all models Number of Pole:1/2/3/4 poles Rated Voltage:250V~(1P)/500~(2P,3P,4P) Rated Frequency:50/60Hz IP Protection:IP66 1. Sample Free, We are manufactoruer factory. weatherproof isolator weatherproof isolator weatherproof isolator 2. For all your inquires about us or our products, we will reply you in detail within 24 hours. 3. We offer OEM services. Can print your own logo on product, can customise the retail box packing and other things. weatherproof isolator weatherproof isolator weatherproof isolator 4. We have very experienced
Model number: H15 Application: Guitar Mounting type: PCB mountable, Welding/Soldering Poles: 1-2 Poles Voltage proof: Check data sheet Timinal strengh: 1 kgf for 1 minute Stopper strengh: 5 kgf.cm min Life Cycles: 10,000 cycles
11 kv. 200 amps. 11 kv. 400 amps 33 kv. 630 amps. 66 kv 400 amps. 1 set in wooden crate.
MCB's
MCCB's
Auxiliary switches Construction Mani make auxiliary switches have silver û plated fixed contacts, made out of brass, held in molded malamine switch plates. The silver-plated moving contacts, made out of phosphor bronze, are molded on nylon û coated central shaft. Any desired contact configuration, from 2no / 2 nc up to 30 no / nc, is possible in one stack. Make-before-break (mbb) contacts can also be provided when required. Any combination of both the types of contacts to suit specific requirement can be offered. Till today, we have supplied more than a lakh of auxiliary switches successfully to various customers in india, including export to malaysia. Optional features Built in snap-action mechanism is offered as an optional extra. Suitable mounting plates as per requirement are also offered as an optional extra. Shaft extensions to suit specific requirements can be provided.