Systematic mechanism that prevents the Air entry into the line when the bottle gets empty. 0.2 micron In- fluid line filter for preventing foreign particles. Transparent & flexible drip chamber. Soft and kink resistant PVC tubing.
Our Doctor's Apron Lab Coat is made up top of the class cotton fabric i.e. Denim As, It is a fabric made of cotton twill that is 100% cotton and very comfortable.
This particular lab coat has dual stitching which makes it extremely durable and can be used in rough and tough conditions also.
Lab coat has 3 pockets. One at the left top Two pockets at the bottom portion of the lab coat.
Color Delighted white. Perfectly designed and shaped for comfort during work.
HD BT Set confirms to international standards. It has special beveled extra strong spike. self sealing latex tube for extra medication & easy flushing. High kink resistant tubing.Roller clamp for Flow controller. Double bag packing ensures sterility till product is actually used.
Disposable non toxic & pyrogen free. Drop size of 20 drops/ml.
Backed by our expertise in the domain, we offer our valued clients Urine Bag.These products are manufactured using high quality raw material, which we procure from the most authentic and reliable vendor in the industry. Moreover, products we offer are fabricated by employing latest technologies and tools in accordance with international quality standards.
General Characteristics
Single-use
Sterile
Including a mechanism to prevent reuse
The syringe and needle shall be passively and automatically rendered unusable by the delivery of the intended fixed dose. And/ Or
The auto-disable feature is automatically activated and remains effective from the time that the injection is commenced. And / Or
The auto-disable feature is automatically activated on completion of the delivery of the intended fixed dose.
Type and application
Non-pre-filled, disposable.
To administer DTP, DT, tetanus toxoid and diluted freeze dried measles etc for intramuscular and sub-cutaneous injection.
Syringes with permanently attached needle
Material
Polypropylene with or without stainless steel
Syringe size with pre-set volume and single marking
0.5ml for immunization (+20% to allow for removal of air)
Graduation and accuracy
Two markings only: 0 and 0.5ml.
The difference between the maximum graduated volume and the expelled volume of distilled water shall not be greater than �± 25 micro-liters.
Needle for Immunization
· Diameter : 23G
Length : 25mm (1)
Stainless steel needle tubing for the manufacture of medical devices
Needle shall confirm to IS 10654 of 2002 (third revision) equivalent ISO 7864 of 1993
Needle fixing
Fixed capped, needle (23 G X 25 mm). Fixed needles should withstand an axial pulling force of 34N without separating from the syringe. If accidental needle stick protection devices are included in the design of the syringes or needle, they should not compromise the ease of use or the performance of the syringe.
Leakage :
Leakage of distilled water at a pressure of 0.3 mPa (3 atmospheres) for six minutes shall not be greater that 50 micro-liters.
Dead space
The maximum dead-space shall be 50 micro-liters.
Self destruction
The syringe shall be automatically rendered unusable when it has delivered a 0.5 ml dose of vaccine or distilled water.
Filling
The syringe is filled by inserting the needle through the septum of a sealed vaccine vial.
x-ray protective lead apron Strictly following the instructions and maintenance of the product can prolong the protective performance and service life of the product, including medical radiation protective lead clothing, lead hat and lead apron protective clothing
The medical X-ray protective series products are made of natural lead vinyl and yellow lead powder, covering with clothing when processing. The lead equivalent is: 0.35mmpb, 0.5mmpb. They are mainly used for the protection of the X-ray
5. [product application]: it is suitable for doctors, patients and X-ray protection during intervention
5. [product application]: it is applicable to the protection of doctors, patients and X-rays and gamma rays during intervention.
6. [scope of application]: applicable to X-ray and �³ Radiation (gamma) protection.
7. [instructions]: before operation, first check whether the wrapping cloth on the inner and outer surfaces of the protective series products is firm, whether the connection of accessories is firm, and whether the lead equivalent on the mark meets your needs. After inspection, wear the protective series products on your body or on your head, neck and feet, and then operate
1. Ultra light, ultra-thin and ultra soft protective materials;
2. Good protection performance: the lead distribution is very uniform, and the lead equivalent will not decay under normal use; Provide 0.35 lead equivalent; Wear resistant and easy to clean surface materials;
3. New structural design: made of multi-layer materials and professional humanized structural design, it makes you feel more comfortable to wear;
X-ray lead cap Lead clothing is a special kind of clothing. Lead clothing can minimize the injury of patients during physical examination by shielding rays.
The intervention protective gloves with the best protective performance today,
In practical work, due to the limited conditions, the purpose of safe operation can not be achieved only by shortening the contact time and increasing the distance.
For example, a large 60 Co irradiation source is installed indoors, and the maximum distance from the staff is only a few meters. The dose equivalent at the staff may be more than 1 Xi / s, and it is dangerous to stay there for one second. Therefore, the above two methods are not applicable, and shielding protection must be adopted. Shielding protection is to add a layer of shield (weakening material) with sufficient thickness between people and radiation sources according to the principle that radiation is weakened when passing through substances, so as to reduce the external radiation dose below the control standard, so as to protect human safety.
The material used for shielding is determined according to different properties, types and output of rays, and its thickness is determined according to the control level. In external radiation protection, the above basic measures must be reasonably applied according to the actual situation. When solving specific protection problems, these measures are often used in combination. For external radiation protection, in addition to the above basic measures, it is also necessary to do a good job in the protection training of staff, monitor the working environment and personal dose, and shield or remove temporarily useless or redundant radioactive substances in time. In addition, any interaction between ionizing radiation and air will produce some harmful gases, such as ozone and nitrogen oxides. At the same time, substances (including air and dust) irradiated by high-energy charged particle beam, neutron beam or high-energy photon beam may also induce induced radioactivity.
Therefore, when applying external ionizing radiation sources, in addition to paying attention to the radiation protection of external radiation, corresponding other measures (such as ventilation) must be taken to prevent the damage of internal radiation, harmful gases and other harmful factors to human body