Non Vacuum Blood Tube Item GDN050EK3, Specification: 5ml EDTA K3 Non-vacuum blood collection tube, Green cap, Item GDN050EK2, Specification: 5ml EDTA K2 Non-vacuum blood collection tube, Green cap, Item GDN050A, Specification: 5ml Plain Non-vacuum blood collection tube, Red cap, Item GDN050CA, Specification: 5ml Clot Activator Non-vacuum blood collection tube, Red cap, Item GDN050SP, Specification: 5ml Fluoride Oxalate Non-vacuum blood collection tube, Yellow cap, Item GDN050LH, Specification: 5ml Lithium Heparin Non-vacuum blood collection tube, Dark Blue cap
Micro Collection Tube Micro Collection Tube is mainly used for peripheral blood collection. It is specially suitable for small children and geriatric patient. The inner surface has an excellent hemorepellency where it is necessary for a good preparation of high quality blood sample. Item GD005A , Specification: Micro Collection tube, Plain, 0.5ml , Item GD005CA , Specification: Micro Collection tube, Clot Activator 0.5ml , Item GD005EK3 , Specification: Micro Collection tube, EDTA K3, 0.5ml , Item GD005EK2 , Specification: Micro Collection tube, EDTA K2, 0.5ml , Item GD005LH , Specification: Micro Collection tube, Heparin Lithium, 0.5ml , Item GD005SH , Specification: Micro Collection tube, Heparin Sodium, 0.5ml , Item GD005SFH , Specification: Micro Collection tube, Heparin Sodium + Sodium Fluoride, 0.5ml , Item GD005SGC , Specification: Micro Collection tube, Gel + Clot Activator, 0.5ml , Item GDNM005A , Specification: Micro tube (High Type ) 0.5ml Plain 0.5ml, Item GDNM005CA , Specification: Micro tube (High Type ) 0.5ml Clot activator 0.5ml, Item GDNM005EK3 , Specification: Micro tube (High Type ) 0.5ml EDTAK3 0.5ml, Item GDNM005EK2 , Specification: Micro tube (High Type ) 0.5ml EDTAK2 0.5ml, Item GDNM005LH , Specification: Micro tube (High Type ) 0.5ml Gel 0.5ml, Item GDNM005SGC , Specification: Micro tube (High Type ) 0.5ml Gel 0.5ml, Item GDNM005SFH , Specification: Micro tube (High Type ) Glucose ( Heparin sodium,/ Sodium Fluoride) 0.5ml
Capillary Blood Collection Tube Item GDC005A , Specification: Capillary Blood Collection Tube, Plain, 0.5ml Item GDC005CA , Specification: Capillary Blood Collection Tube, Clot Activator, 0.5ml Item GDC005EK3 , Specification: Capillary Blood Collection Tube, EDTA K3, 0.5ml Item GDC005EK2 , Specification: Capillary Blood Collection Tube, EDTA K2, 0.5ml Item GDC005LH , Specification: Capillary Blood Collection Tube, Heparin Lithium, 0.5ml Item GDC005SH , Specification: Capillary Blood Collection Tube, Heparin Sodium, 0.5ml Item GDC005SFH , Specification: Capillary Blood Collection Tube, Heparin Sodium + Sodium Fluoride, 0.5ml Item GDC005SGC , Specification: Capillary Blood Collection Tube, Gel + Clot Activator, 0.5ml
Butterfly Blood Collection Set. EO STERILIZATION Single Blister Package Specification: 21G, 23G, 25G, CUSTOMIZED MOQ 100K Sterile Pack, Single use only Color coded for easy identification of needle sizes Ultra-sharp needle tip minimizes patient discomfort More comfortable double wings design, easy operation Customized sizes available 510K approved CE approved ISO
Vacuum blood collection tube Type: Clot activators Gel separator / Clot activator K3-EDTA Anticoagulant K2-EDTA Anticoagulant Sodium Citrate 3,8% Anticoagulant Sodium Citrate 3,2% Anticoagulant Sodium Flouride/ Potassium Oxalate Lithium Heparin Anticoagulant ESR - Sodium Citrate 3,8% Granules & Clot Activator Vacuum Tube for Urine Collection. Most blood collection tubes contain an additive that either accelerates clotting of the blood (clot activator) or prevents the blood from clotting (anticoagulant). A tube that contains a clot activator will produce a serum sample when the blood is separated by centrifugation and a tube that contains an anticoagulant will produce a plasma sample after centrifugation. Some tests require the use of serum, some require plasma, and other tests require anticoagulated whole blood.
Vacuum Blood Collection Tube introduced by us promises to live up the expectations of the buyers. It is manufactured completely in clean room environment by using the best of the quality materials and assembled on a 100% Automatic assembly Line. We believe in quality and the same has been inculcated in our products. We produce the tubes in two volumes 13 75 mm and 13 100 mm. Variants : K2 EDTA (2 ml - 6 ml) K3 EDTA (2 ml - 6 ml) Clot Activator (2 ml - 6 ml) Sodium Heparin (2 ml - 6 ml) Lithium Heparin (2 ml - 6 ml) Sodium Fluoride (2 ml - 6 ml) Sodium Citrate (2 ml - 6 ml) Gel with Clot Activator (3.5 ml - 5 ml) We follow the colour codes of ISO 6710:2016 for the manufacturing process of the tube.
Test tubes
Product name:Vacuum blood collection tube Cap color : Red, blue, yellow, green, black, purple, gray Draw volume:1-10ml Specifications:12x75mm,12x100mm,13x75mm,13x100mm,16x100mm Material:plastic,glass
Product name:Vacuum blood collection tube Cap color : Red, blue, yellow, green, black, purple, gray Draw volume:1-10ml Specifications:12x75mm,12x100mm,13x75mm,13x100mm,16x100mm Material:plastic,glass
15 ml conical bottom centrifuge tubes (falcon type) with screw cap water and air tight. with volume graduation with sanded blurred writing area. sterile or nonsterile polypropylene excellent quality
Transport tubes, sometimes called mailing tubes, are used in multiple sectors of the laboratory market, including environmental, independent testing, food testing, and biological research labs. PekyBio's transport tubes are made from polypropylene (PP), and screw caps are Polyethylene (PE). Tubes are self-standing with conical bottom and molded graduations. Vailable in 5 mL and 10 mL, non-sterile and gamma radiation sterilized.
Transport tubes, sometimes called mailing tubes, are used in multiple sectors of the laboratory market, including environmental, independent testing, food testing, and biological research labs. PekyBio's transport tubes are made from polypropylene (PP), and screw caps are Polyethylene (PE). Tubes are self-standing with conical bottom and molded graduations. Vailable in 5 mL and 10 mL, non-sterile and gamma radiation sterilized.
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%
Vacuum Blood Collection Tube/Disposable Vacuum Blood Collection Tube Blood Collection Tube Materials: PET/Glass Blood Collection Tube Size: 1ml-10ml available Additive Type available: Blood Collection Tube + No additive Blood Collection Tube + EDTA k2 Blood Collection Tube + EDTA k3 Blood Collection Tube + Heparin sodium Blood Collection Tube + Heparin lithium Blood Collection Tube + Sodium citrate1: 9 Blood Collection Tube + Sodium citrate1: 4 Blood Collection Tube + Seprate Gel+Clot activator Blood Collection Tube + Fluoride/oxalate Blood Collection Tube + Clot activator cap color normal specification material blood drawing volume packing additive red 13*75 PET 1-5ml 1200pieces/carton non 16*100 PET 8-10ml 1200pieces/carton purple 13*75 PET 1-5ml 1200pieces/carton EDTA-K3 black 8*120 glass 1.28ml 1200pieces/carton 0.129M sodium citrate 1:4 blue 13*75 PET 1.8ml 1200pieces/carton 0.109M sodium fluoride/CTAD 1:9 green 13*75 PET 1-5ml 1200pieces/carton heparin lithium yellow 13*75 PET 1-5ml 1200pieces/carton separation gel/coagulation accelerator 13*100 PET 5-7ml 1200pieces/carton Lithium Heparin/Sodium Heparin Vacuum Blood Collection Tube
It is product made of ABS material which is compatible 90/100 pieces blood tubes.
It is a product made of ABS material, which can carry 68 blood tubes in 3 different sizes.