Wrist Splint (Conventional) AJY-S05 For wrist or proximal forearm fractures, functional position fixation in wrist arthroplasty, and rest position system for wrist arthritis and other lesions Dynamic or lunate dislocation and colles fracture fixation. 270*192*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Wrist Splint (Stable) AJY-S10 For wrist or distal forearm fractures, functional fixation of wrist arthroplasty. However, the dorsal side of the wrist needs to be exposed (if there is a wound on the volar side). 275*175*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Finger fixing splint (tubular type) AJY-S01 Tubular finger fixation for phalangeal fractures, knuckle dislocations, ligaments, tendon injuries and fixation. 190*120*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Wrist Splint (Simple Type) AJY-S04 For wrist soft tissue injury, wrist arthritis and functional position fixation. 303*193*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
the Cordis Emerald Guidewire is a product developed by Cordis Corporation, a subsidiary of Cardinal Health. Guidewires are medical devices used in various interventional procedures to navigate through blood vessels, providing access for other devices and treatments. Key features of the Cordis Emerald Guidewire may include: Material: The guidewire is typically made from materials like stainless steel or nitinol, which offer flexibility and support for navigating through the vascular system. Coating: Guidewires may have hydrophilic or hydrophobic coatings to enhance their lubricity, making it easier for them to pass through blood vessels. Tip Design: The tip of the guidewire is often designed to be atraumatic, reducing the risk of vessel injury during navigation. Radiopacity: The guidewire is often designed with radiopaque markers to aid in fluoroscopic visualization during procedures. Length and Diameter: Guidewires come in various lengths and diameters to suit different procedures and anatomies.
the Boston Scientific Promus Elite is a coronary drug-eluting stent system. It is designed for use in patients undergoing percutaneous coronary intervention (PCI) procedures to treat coronary artery disease. Here are some key features and points related to the Boston Scientific Promus Elite coronary stent: Drug-Eluting Stent: The Promus Elite is a drug-eluting stent (DES), meaning it is coated with medication to help prevent the re-narrowing (restenosis) of the treated coronary artery. Drug Coating: The stent typically features a polymer coating containing an anti-proliferative drug. This drug is slowly released over time to inhibit the growth of tissue inside the stent, reducing the risk of restenosis. Cobalt Chromium Alloy: The stent is often made of a cobalt chromium alloy, known for its strength and flexibility. This material allows for a thin stent strut design, which can be beneficial in terms of deliverability and conformability. Delivery System: The stent is delivered to the target area using a catheter-based delivery system. The catheter is guided through the blood vessels to the site of the coronary artery lesion. Radiopaque Markers: Radiopaque markers on the stent aid in proper placement and visualization under X-ray guidance during the procedure.