The EMR/EHR system is specifically designed to provide a central portal for all doctors to secure patient health information. It offers secure storage and easy access for Healthcare providers whenever a patient comes to them. Healthray EMR has many advanced features, like facilitating comprehensive and deficient documentation and providing a way for healthcare professionals to make informed decisions. These are helpful in improving overall patient outcomes and coordination. There will be no need for doctors to operate on the previous module, where they need to go through a lot of papers in order to analyze the condition of the patient and come up with a treatment plan.
Breast implants MENTOR 275cc M+
Breast implants MENTOR 250cc HP
Breast Implant Mentor 275cc HP
Disposable cardiovascular drapes for cardiovascular surgery offer effective fluid control for a dry working area. SIDE DRAPE REINFORCED SURGICAL GOWN TOWEL MAYO COVER BACK TABLE COVER PACK
Uniform fabrics, uniforms, work wear, coveralls, etc.
Woven/knit and non woven fabric and its relative products like disposable medical products, home/hotel textiles, essential oils, household appliances, kitchenware, fiberglass mesh cloth, etc..
The Tibial End Cap is available in 3 different extension options. It can extend by 0mm, 5mm, or 10mm. It is used with all Tibial Intramedullary Nails.
The 5mm diameter locking screws are used in the proximal and distal locking holes of the Tibial Intramedullary Nail.
The Femoral End Cap is available in 5 different extension options. It can extend by 0mm, 5mm, 10mm, 15mm, or 20mm. It is used with all femoral intramedullary nails.
The Femoral Recon Screw is used in femoral neck fractures and fractures in the trochanteric region. The screw's thread profile is designed to be suitable for spongy bone structure and has a self-tapping feature.
The Femoral Locking Screws have a 5mm diameter and are placed at an angle from major to minor in the proximal part of the nail. Additionally, they can be used in L/M in the minor.
The PFN Cannulated Set Screw is used to secure the PFN Compression Screw and the PFN Lag Screw.
The PFN End Cap is a single type and is used in all PFN Intramedullary Nails.
The PFN Compression Screw works in integration with the PFN Lag Screw. If compression up to 5mm is desired on the fracture line, the compression screw should be selected to be 5mm shorter than the lag screw. If 10mm compression is desired, the compression screw should be selected to be 10mm shorter than the lag screw.
The PFN Lag Screw has a diameter of 11mm and is channeled throughout its entire length. It also features a cannulated structure and works integrally with the compression screw.
The Trochanteric Intramedullary Femoral Nail: This nail is preferred for fractures in the trochanteric region, femoral neck fractures, subtrochanteric fractures, and shaft fractures. The nail has a round shape. The proximal part has 4 screw holes, 2 of which are suitable for the passage of recon neck screws, and the other 2 for locking screws. The lateral angle of the proximal part is 5°. The distal part of the nail has two locking screw holes, one of which includes a slot for static or dynamic fixation.
PFN Intramedullary Nails: These are used in proximal femoral neck fractures, subtrochanteric fractures, and intertrochanteric fractures. The proximal part of the nail has a triangular cross-section with a radiused, angled design that prevents rotation. The distal part has a circular cross-section with a slot that allows for both dynamic and static locking. Additionally, the distal part is channeled, designed to reduce thigh pain. The proximal section includes a channel at a 125° angle through which the integral compression and compression screw pair passes. This screw pair can provide up to 10mm of compression at the fracture line using the appropriate sizes. An inner compression screw is used to restrict the movement of this screw pair. Additionally, a peak screw is located at the proximal end. The nail has a cannulated, closed structure and features a 5° lateral offset angle.
They are used in proximal, distal, and shaft fractures of the tibia bone. It has a cannulated and circular cross-section with curves, featuring 3 distal and 4 proximal holes through which the locking screws pass. The Tibial Intramedullary Nail has a 10° proximal offset angle and a 3° distal offset angle. The 3 distal holes are for static locking only. One of the 4 proximal holes is a slot designed for either dynamic or static locking.
- I.V. Set - Economy Plain Latex Non-Air Vented - I.V. Set - Economy with Latex Bulb Non-Air Vented Box Packing (Paper Pack) - I.V. Set - Regular with Latex Bulb Non-Air Vented Box Packing (Paper Pack) - I.V. Set - Regular with Latex Bulb Non-Air Vented (Ribbon Pack) - I.V. Set - Premium with Latex Bulb Non-Air Vented (Ribbon Pack) - I.V. Set - Premium with Y-Connector & Luer Lock Air Vented (Ribbon Pack)