Sample rule
Option 1: Offering existing samples
Option 2: Customized samples based on customers' specifications
Sample lead time
3-10days (depends on the style)
Result: 15 Minutes
Shipping mode
1.Sea shipment
2.Air shipment
3.Door to door parcel
Intend to use
1.The New Coronavirus (Sars-CoV-2)Test is a rapid chromatographic immunoassay for the qualitative detection of Antibody(IgG) to coronavirus in human whole blood, serum or plasma specimens.
2.Common signs of coronavirus infection include respiratory symptoms, fever, cough, wheezing and dyspnea. In more severe cases, the infection can lead to pneumonia, severe acute respiratory syndrome, kidney failure and even death.
Corona viruses can be excreted through respiratory secretions, transmitted through oral fluids, sneezing, contact, and through the air droplets spread.
Positive:1. Two or three distinct lines appear. One line should always appear in the control line region (C), and another one or two apparent colored line(s) should appear in the test line region(s) (T1 and T2).
2. If a line appears on the quality control line, a line appears on the test line T1, and no sline appears on the test line T2, it indicates that IgG antibody is present in the sample and no IgM antibody is present.
3. If a line appears on the quality control line, a line appears on the test line T2, and no sline appears on the test line T1, it indicates that IgM antibody is present in the sample and no IgG antibody is present.
Negative: One colored line appears in the control region (C). No Apparent colored lines appear in the test lines regions (T1 and T2).
Invalid: Control line(C) fails to appear. Insufficient specimen volume or incorrect procedural technologies are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Note: The red line in the test line (T) can show different shades of color. However, even a very weak line should be judged as a positive result during the specified observation period, regardless of the color of the line.
2153 Medical Healthcare Suppliers
Short on time? Let Medical Healthcare sellers contact you.
Rapid Result COVID -19 (SARS CoV-2 ) Tests
(whole blood/serum/plasma) COVID-19 IgG/IgM Rapid Test Cassette
Made in the USA
Results Show in 10 Min. or Less Simple, Time-Saving Procedure Highly Sensitive and Specific
25 Tests per Box MOQ - 16,000 Tests is 1 Pallet
This IgG/IgM antibody detection test is a rapid visual immunochromatographic sandwich assay for the qualitative detection of IgG and IgM antibodies from human whole blood or serum.
Rapid Test Cassettes are intended for point of care application, not for home use. Results from this test should not be used as the sole basis to diagnose or exclude SARS- CoV-2 infection or to inform infection status.
Positive results may be due to past or present infection with non-SARS-CoV-2 coronavirus strains (coHKU1, NL63, 0C43, or 229E). Consider follow up testing with molecular diagnostic to rule out infection in these individuals.
Negative results do not rule out SARS-CoV-2 infection, particularly in those who have been in contact with the virus. Results from one antibody testing should not be used as the sole basis to diagnose or exclude SARS-CoV-2 infection or to inform infection status.
n pyrogenic
6) shelf life : 3 years
7) quality certificate : ce0123, iso13485,
8) standard : the physical, chemical and biological tests comform to standard of iso7886
Packing : individual in blister or pe bag, 100 pcs in one box, carton package in outside
Fg xpress powerstrips™ are a doctor formulated 'first-of-it's-kind' product listed by the fda as a class 1 medical device.
Powerstrips are a patented fusion of modern breakthrough technology and ancient herbs providing an all-natural solution for pain relief.
Try it now! (looking for distributors too!)
Http://bit.Ly/1bunfj9
Freestyle breast pump
1 set of tubing
2 softfit™ breast shields
Breastshield spare parts kit
2 breastshield bodies; 2 membranes; 2 back caps
Support belt & extension
Hands-free kit
2 replacement adapters; 2 small (yellow) straps; 2 large (gray) straps
2 replacement bra adapters - universal
2 replacement bra adapters - hook & eye
4 - 5 oz. Containers
Power cord & charger
Cooling element
4 solid lids
1 rechargeable battery
Contact number 0103651294
Medela freestyle double electric breastpump with tote 67060 bpa-free
Patented device use for IUI procedure in treatment of infertility.The device is designed specifically for IUTPI with good success rate of pregnancy close to 26%.