Warranty: 1 year Features: Manual lens meter Battery oprated Electric oprated Axis marking Sphere 0 to +/- 25d (0.01d, 0.12d, 0.25d steps) Clyinder 0 to +/- 10d (0.01d, 0.12d, 0.25d steps) Axis 0-180 (1 steps)
Warranty: 1 year Taglines: Sensitive lcd touch display screen Adjustable lcd display screen Automatic recognition of single and progressive lens Hi-speed uv measurement Measurement screen Progressive measurement Built-in thermal printer Place for uv test Standard case : carrying aluminium case Features: Automatic recognition of single and progressive lens , built-in uv tester , user friendly design jd 2600a / b is a product that will provide you a comfortable usage This new generation of auto lensmeter is based on hartmann sensor technology advanced simultaneous measurement of 108 points provide a faster measurement with greater accuracy and reliability Sphere power (sph): 0~+/-25d 0.01 / 0.12 / 0.25d steps Cylinder power (cyl): 0~+/-9.99d 0.01 / 0.12 / 0.25d steps Axis (ax): 0-180(1 steps) Addition: 0~ +9.99d 0.01 / 0.12 / 0.25d steps Prism: 0~15 0.01 / 0.12 / 0.25d steps Step: 0.01d Pupil distance (pd): 45~90mm . 0.5 mm steps Lens diameter: 20~108mm Uv tester: >100% (+/-15.00d - +/- 25.00d , >20%) Measurable: Single / progressive / automatic / rec0gnition Contact lens: Soft / hard Display: Tft lcd jd 2600a (7) jd 2600b (5.6) Printer: Thermal printer Power source: 100-120v~/200-240v~ chooseing 50 or 60hz Weight: ~5kg Power supply: 100~240v 50~60hz
DYNAMIC PASS BOXES - Dynamic Pass Box (aka Pass Through Box or Clean Pass Box) is primarily designed to minimize man and material movement between different classified areas thereby minimizing the chances of cross contamination. Pass Box is an essential equipment for any manufacturing or research facility which requires maintaining the integrity of different classified areas.
FUME HOOD - Fume Hoods (aka Fume Exhaust Hood) are designed to exhaust and contain toxic, obnoxious or otherwise harmful gases, vapors, mist etc. to protect laboratory workers and equipment. A motor driven blower creates negative pressure within the work area, extracting the contaminated air from work area and expel it into the atmosphere. The Hood is ventilated of the air drawn from inside the laboratory which is used effectively for thorough sweep-out of work area.
WARRANTY: 1 YEAR FEATURES: WHEEL 125 X 25 X 20MM 'V' GROOVE WHEEL BUFFING ATTACHED
WARRANTY: 1YEAR FEATURES: METAL BODY GRINDING MACHINE WITH BUFFING WHEEL SIZE :125 X 25 X 36 IN MM 4 IN 1 MACHINE :PC,GLASS,CR&'V'GROOVE
Measuring Range: -20~+20D(VD = 12,0.12D / 25D STEPS) -10~+10D (0.12D/25D STEPS) 1~180 ( 1 STEPS ) Pupil Distance: 30~85mm, 1mm STEPS Vertex Distance: 0mm, 12mm, 13.75mm , 15mm Min.Pupil Size: 2.0mm Chart: AUTO FOG Display: 5.7TFT LCD Print: THERMAL PRINTER Power Supply: 100~120V / 200~240V, 50 / 60Hz Dimensions: 480 (L) X 270(w) x 445 (H) mm-mm-mm Weight: 17 KG Features: 1. PUPIL DISTANCE AUTO MEASURED 2. WITH AUTO - TRACING FEATURE , OPEREATER CAN ADJUST THE FOCUS AND ALIGNMENT IN UP AND DOWN DIRECTIONS 3. WITH AUTO VIDEO TAPING FEATURE , OPERATOR CAN TAKE MEASUREMENTS AUTOMATICALLY ONCE EQUIPMENT OBTAINS SATISFACTORY FOCUS AND ALIGNMENT 4. WITH SERVO CHIN-REST , OPERATOR CAN ADJUST HEIGHT OF CHIN-REST EASILY 5. DISPLAY IS TILT - ADJUSTABLE 6. PRINTER HAS A PAPER AUTO CUT WARRANTY: 1 YEAR TAGLINES: 1. 5.7' LCD TILTABLE COLOR DISPLAY 2. PRINTER WITH AUTO CUTTING 3. PD MEASUREMENT 4. AUTO FOG CHART 5. VERTEX DISTANCE 6. AUTO CHIN-UP AND DOWN 7. AUTO ALIGN AND FOCUS
AUTO REFRACTOMETER / KERACTOMETER
W3/330 system is based on the electrolytic sensor method to measure water vapor transmission rate of film and package specimens. It has three independent testing cells and can be easily connected with 9 satellite systems. Benefits : Increase sample throughput Available for high barrier materials Simulate some realistic application of packaging conditions in the market
TSY-W3 is professionally applicable to determination of water vapor permeability of plastic films, high barrier materials, back-sheets, sheeting, aluminum foils, waterproof materials, and other materials used in sanitary and medical industry.
W3/230 is based on the infrared sensor method and designed for the determination of water vapor transmission rate of film and package specimens. It is applicable to various materials with high, medium and low water vapor permeability. Benefits : Increase sample throughput Available for high barrier materials Simulate some realistic application of packaging condit ions in the market
W3/130 is based on the humidity sensor method and is professionally applicable to the water vapor transmission rate test of film specimens.
W3/130 is based on the humidity sensor method and is professionally applicable to the water vapor transmission rate test of film specimens.
Screw Storage caps, septa, and vials are designed especially for use with Agilent's and otherrotating or robotic arm samplers . Storage vials are manufactured of Clear, Type 1 Class A or Amber, Type 1 Class B borosilicate glass . Caps are made of high quality polypropyleneto exact manufacturing tolerances and lined in a controlled manufacturing environment . Our septa only use the highest quality materials to ensure proper function and can be pre-slit to ease needle penetration. Designed for single injection and/or short sample cycles, particularly for LC applications Absence of elastomer layer reduces potential for contamination. Features: Volume/Capacity:� 20ml, 40ml, 60ml (Normal Volume) Feature: 27.5*57mm, 27.5*75mm,27.5*95mm, 27.5*140mm vials, 22*3/22*1.5mm PTFE/Silicone septa, 20mm PP screw cap Qty/Pack: 100/pack z Model:� Storage screw-thread vials
The fiskeâ® 210 micro-sample osmometer The fiskeâ® 210 freezing-point osmometer requires only a 20âµl sample size, which provides accurate osmolality results in less than 90 seconds. For convenience, the fully accessible probe design is easy to clean and service. The 210 is not only your most reliable option, it's the easiest to use. Just pipette 20âµl of sample into a disposable sample tube, then place the tube into the test chamber. Lower the probe into the sample and push the "test" button. Results are displayed in ninety seconds. Features Alphanumeric display: results, user prompts, and instrument diagnostics are clearly displayed. Easy push-button operation: requires minimal operator training. Printer, rs232c and barcode scanner ports: a full range of data handling options is available. Unit connects easily to printer, computer and scanner. Automatic calibration: no fine-tuning or user adjustments during calibration. The instrument's microprocessor automatically makes calibration adjustments at the push of a button. Smallest sample size: only 20âµl of sample needed. Solid-state cooling: the 210 has no liquid cooling bath; no maintenance required.
Achromatic objectives: 4x, 10x, 40x(s), 00x(s, oil) Eyepiece: wide field eyepiece wf10x(wf16x optional) Viewing head: sliding binocular head inclined at 45° , 360° rotatable Stage: double layer mechanical stage size 140x140mm, moving range 75x45mm Focusing: coaxial coarse and fine adjustment, focusing range 30mm, focusing interval 0.002mm Condenser: abbe na=1.25 with lris diaphragm&filter Illumination : led adjustable (halogen lamp optional)
Double-glazed designed glass reactor, the liner is for reaction solvent, and the jacket for heating or cooling resource(cool liquid, hot water or hot oil), to achieve circulating heating or cooling experiment. And its ancillary equipment-high and low temperature machine which can satisfy functional high & low temp reaction experiments.
Fiber optic spectrometer with the advantages of modularization and flexibility of its measuring system is widely used to measure wavelength and line width of laser, LED and common light source, can accurately obtain the spectral characteristics of the light source which is being tested. CNI developed spectrometers with the characteristics of compact and portable design, plug and play, easy operation and Spectral Analysis 5.0 software downloads, which are extensively applied on the fields of scientific research, teaching, industries and many other applications. CNI can also customize the wavelength and resolution of the spectrometers according to different customers’ demands.
Laser power meter is used to measure laser power and power stability. CNI as a world's leading designer and manufacturer of laser system, designed several laser power measurement instruments with the features of accuracy testing, easy operation, etc., which could fully meet customer's practical needs of laser power and power stability measurement. They are widely used in the research, teaching, medical science, industry and other fields.
The finest experimental facilities in the country rely on KC Hydraulic Engineering Labs for accurate analysis and superior precision. Our equipment of Hydraulic Lab explain the principles of bernoulli’s theorem, continuity, momentum and many more concepts that are applied to fluid motion. The Hydraulics Laboratory offers many testing facilities including fluid mechanical, hydraulic machinery, wind tunnel, flow channels and computer-controlled equipment, pumps etc.