Please click here to check who's online and chat with them.

Find Verified Laboratory Equipments Instruments Suppliers, Manufacturers and Wholesalers

Oct-12-09
 
Feature
It can automatically record the temperature while the deformation of the specimen reaches the preseting value and the test of HDT/VICAT ;it can be easily performed respectively by replacing the header of the loading rod.

Weight 426 kg
Dimension 140X65X180 cm
Oct-12-09
 
The tester is used to determine the impact resistance of plastic tube. The design of the tester is accordance with DIN-EN 744, BS-EN 1411, and ISO-3127.
Oct-12-09
 
Method:

Absorbance
Mono û Chromatic
Bi û Chromatic
End Point with standard / factor
Fixed Time Kinetics
Mutipoint Kinetics
Multi Standard up to 8-Standards

Optical System
Principle Photometry
Range of measurement
From 0 û 2.5 A for 340 nm
From 0 û 3.0 A for 405 nm &
Upwards
Automatic Zero Setting
Halogen Lamp 12V 20W
Spectral range selection:
Automatic via filter wheel

Measurement Apparatus
Removable Cuvettes
Semi û Micro and Micro
Silicon Photodiode

Display and Keyboard
Blue Screen 4x20 LCD
PCB Optimized Membrane
Keypad

Memory Storage Capacity
100 û Tests
8 û Units
Sep-29-09
 
Borosilicate.
Sep-16-08
 
Fsm-60LE glass surface stress tester

Product name: fsm-60LE glass surface stress tester
Supply ability: 100
Specifications fsm-60LE
Price term: fob
Port of loading: shanghai
Minimum order 1
Unit price: negotiable


Fsm-60LE accurate measurement of chemical and heat-resistant glass surface stress. Birefringence in the measurement principle is very important. Sodium lamp as light source, measurement pattern is very clear. The chemical products suitable for measuring the stress and the surface of tempered glass containers depth.



Original packing.
4347 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
Sep-16-08
 
Surface stress meter fsm-6000LE

Thisfsm-6000LE is developed for measuring surface stress of glass with pc. Chemical and thermal tempering is increasing the areas of glass application in most of industries. The optical waveguide effect in the surface layer of temperd glass is a useful tool for measuring surface stress for quality and process control purposes.

Fsm-6000LE suitable for measuring chemical and heating glass, automatic detection through a computer. Detection of the man-made computers to reduce the error. Under normal circumstances, complex testing needs to come to the calculation of stress, but the automatic measurement of not only save time, computer products, are preserved by the relevant inspection data.

Specification:
Range:0-1500mpa
Accuracy:20mpa
Light source:sodium lamp
Sample:chemical tempered glass
Sample:thermal tempered glass
Sample size: flat over1010
Prism: nd=1.72
Power source:ac100v 3a


Sample size: flat over10*10MM
Sep-16-08
 
Lsm-901 glass surface stress tester

Lsm-901 applied to the glass surface stress test, stress range of 100-1500 mpa (mn/m2). Lsm-901 usually semi-tempered glass measuring the stress and measurement process is very fast. Compact design aesthetic appearance, when used to install a battery, can be measured anywhere. Lsm-901 through the appropriate replacement eyepiece micrometer, the chemicals can be heated glass for testing.

Original packing
Aug-04-09
 
Noritsu/fuji digital minilab machines.
Jul-27-09
 
Performance:
1. Reasonable software, programmable biochemical test menu, 200 test programmes can be saved.
2. 1000 patients test data can be saved.
3. Clock CMOS chip inserted.
4. Hermetic solid-state optical system, low contamination of dust and dampness,long life time of hard membrane filters.
5. Back spectro photometry, 8 hard membrane filter, separate signal process circuit for each wavelength, filters select completed electronically,no mechanical movement.
6. Titanium alloy flow cell with small capacity and minimize cross-contamination.
7. Back-light LCD monitor and display character and curve simultaneously
8. Self-test program, test error<1%, CV<3%
Environment:
Temperature :0 degree celsius-40degree celsius
Humidity: 5-80%
Technical feature:
1.Analysis method: kinetics, end point, two point, etc.
2.Power supply: 20w/12V halogen light, life time: 2000hr
3.Optical system: 340-800nm, 8 hard membrane filter: 340, 380, 405, 492, 510, 546, 578, 630nm(wavelength). Accuracy less than or equal to2nm
4.Abs range: -2.500í¬2.5Abs, resolution:0.001Abs.
5.Flow cell: titanium quartz alloy, 33uL; optical path: 10mm.
6.Temperature: PELTIER elements, 25,30,37 ,more or less0.1degree celsius
7.Precision: error<1%, drift<5mAbs/hr
8.200 test programmes can be saved
9. 110mm thermal printer, no noise, high speed, easy maintenance.
10.Keyboard: 24 keys touch keyboard
11.Power supply: 220V mre or less15%, 50Hz, 70VA
12.Interface: standard RS232 serial interface
13.Dimensions : 500(L)x360(W)x240(H)mm
14.Weight: 16Kg(net), 18Kg(gross).
Jul-20-09
 
Levelgauge glass
Its made from borosilicate, it is used in lever gauge in boiler for water position.
It is also named: reflex gauge glass, sight glass, reflex glasses, reflex sight glass, spares for
Level gauge.

The category is as follows:

1) three tendons (four grooves) 2) two tendons (three grooves)
3) plan transparent
Three tendons (four grooves)
340 x 34(30) x 17mm; 320 x 34(30) x 17mm; 280 x 34(30) x 17mm;
250 x 34(30) x 17mm; 218 x 34(30) x 17mm; 190 x 34(30) x 17mm;
165 x 34(30) x 17mm; 140 x 34(30) x 17mm; 115 x 34(30) x 17mm;
400 x 34 x 17mm; 370 x 34 x 17mm; 300 x 34 x 17mm;
400 x 34 x 17mm; 370 x 34 x 17mm; 300 x 34 x 17mm;
The other size is optional or according to the requirements of customers.
Working temperature: 260 ípc, working pressure: 4.0mpa.
Two tendons (three grooves)
340 x 34 x 17mm; 320 x 34 x 17mm; 280 x 34 x 17mm;
250 x 34 x 17mm; 218 x 34 x 17mm; 190 x 34 x 17mm;

Transparent plane

340 x 34 x 17mm; 320 x 34 x 17mm; 280 x 34 x 17mm;
250 x 34 x 17mm; 218 x 34 x 17mm; 216 x 34 x 17mm;



Paper box
Apr-13-09

Culture Dish

$0.70
MOQ: Not Specified
 
Cell Culture Dishes are manufactured from (USP class VI) virgin polystyrene to eliminate all materials and to ensure cell integrity. These dishes are ideal for cell culture and cell harvesting; available in four dish sizes with or without plasma treated surfaces. Plasma treating causes the otherwise very hydrophobic polystyrene surface, to become negatively charged and hydrophilic; allowing cells to attach and multiply. Growth surface areas are flat and free from striation to maximize usable growth area and transparency. The rim on upper side of the lid mates with the bottom of dishes for easy and secure stacking; spacers on the underside allow aerobic gas exchange while providing sample protection. Dishes are sterilized by gamma irradiation and are certified non-Phylogenic.

Feature :-

Uniform wall thickness ensures distortion-free well bottoms.
Either surface-treated or non-treated
Flat bottom Uniform wall thickness ensures distortion-free bottom
Dish surface is smooth and free from striation to maximize usable area for growth
The rim on upper side of the lid mates with the dish brim for easy and secure stack
Lids with several little chimps to shape vents are available for very effective gas exchange

1200/box
Apr-13-09
 
Introduction
Culture Flasks are perfect manufacture for cell growth and cell yields aim on little and medium input volume. MS« offers the selection of 4 different growth areas of 12.5, 25, 75 and 182 cm2 which are easy to open packaging, variety of flasks and assortment of caps. 2 different cap styles can be used in both open and closed systems,Plug Sealing Caps :Standard polyethylene caps can be used in closed systems, providing a liquild and gas sheer seal. But if you simply unscrew the cap one quarter of a turn, this cap can also be used in open system ;Vent Caps:Vented polyethylene caps contain a 0.228m hydrophobic filter to allow gas exchange and minimize risk of cross-contamination

Feature
Flask surface is flat and free from striation to maximize usable growth area
innovative angled neck design offer good pipette and cell scraper access in
Upper triangular and wider base shape provides stability
Both flank sides have engraved graduation
Strict leakage tested
Certified non-pyrogenic


200/box
Apr-13-09
 
Introduction
Culture Plates are ideal for cell culture and cell harvesting; available with five different growth surface areas either surface-treated or non-treated. Growth surface areas are flat and free from striation to maximize usable growth area and transparency. Manufactured of (USP class VI) virgin polystyrene to eliminate all extraneous materials and ensure the integrity of your cells. The surface of treated plates is modified with plasma causing the otherwise very hydrophobic polystyrene surface, to become negatively charged and hydrophilic, allowing cells to attach and multiply. Raised rims on wells reduce the risks of cross-contamination and nestle into rings on the lid to reduce evaporation. One direction lid has venting system that assists in controlling gaseous exchange. A rim on the top of the lid is designed for secure stacking. All plates are sterilized by gamma irradiation and individually packaged in paper/plastic peel pouches; non-pyrogenic.

Feature
Uniform wall thickness ensures distortion-free well bottoms.
Each well is labeled with alphanumeric marking .
Available DNAse/RNAse free .
Non-toxic .
Gamma radiation sterilization.


100/box
Apr-13-09
 
Product description:

Roller Bottles for Cell Culture are manufactured of optically clear polystyrene. Bottles can be used for both research and manufacturing applications, including the growing of mammalian cells for purposes of virus propagation and bio-product production.

Features
Wide cell growth area of 750cm2 for adhesions and huge growth volume for suspension
Available with 1 bottle volume of 2000ml
Either surface-treated or non-treated
Designed large knurls on the cap for easy grip
Bottle surface is smooth and free from striation to maximize usable area for growth
Every bottle has silk-printed graduation
Suitable for all the common instruments and automation
Sterilized by gamma irradiation
Certified non-pyrogenic


24/box
Apr-13-09
 
Ms« disposable polystyrene aspirating pipettes are suitable for most brand of pipette-aid. Ultrasonically welded at the tip and the mouth-piece for added strength and safety.It can be used for all vacuum-aspirating procedures, besides, individually packaged in thermoformed paper/plastic wrap to ensure contamination-resistant presentation

Feature
Nongraduated pipettes
Can be used for all vacuum-aspirating procedures
Nonpyrogenic
Colorless, transparent
Gamma radiation sterilization
Application
Tissue culture
Bacteriology
Tissue culture additive filtration


800/box
Mar-06-09
 
A one scientific & laboratory instruments co. Are manufacturer & exporter of all type of laboratory glassware, scientific, surgical, medical, hospital, laboratory, dairy, milk testing instruments & equipments under sparsh brand including chemical, charts, models & slides

International standard
Jul-24-06
 
Laboratory glassware
Feb-10-09
 
Ultra darkfield live blood microscopy system

Biolution (malaysia) lab services is a fast growing and first company in malaysia provider for the true ultra darkfield microscopy evaluation system. We specialize in live blood analysis and dry-layered blood evaluation.
The live blood analysis by using our system can reveal and pin-point many underlying issues which are contributing to a current health challenge and although not diagnostic in itself, blood analysis will help the practitioners to highlight the factors compromising the ability to achieve balance and health. The darkfield microscope is a vital instrument for the supervision of biological therapies. For example, therapy tests can be made by adding blood directly to the medication and by controlling its reaction. The examination is very motivating for the client because the results can be discussed and demonstrated live on the screen. It cannot be replaced by any other blood examination, neither by normal microscope examination, nor by blood tests sent to laboratories. The blood rapidly changes its function with changes of the inner terrain after taking a sample.


20kg
Feb-02-09

Uv-Spectrophotometer

$123.0k
MOQ: Not Specified
 
Specifications

Wavelength range 190 to 1100nm
Spectral bandwidth 1nm (190 to 1100nm)
Wavelength display 0.1-nm increments
Wavelength setting 0.1-nm increments (1-nm increments when setting scanning range )
Wavelength accuracy ¦0.1nm @ 656.1nm D2
¦0.3nm (190 to 1100nm)
Wavelength repeatability ¦0.1nm
Stray light less than 0.02% NaI @ 220nm, NaNO2 @ 340nm
less than 1.0% KCl @ 198nm
Photometric system Double Beam
Photometric range Absorbance: -4to4 Abs
Transmittance: 0% to 400%
Photometric accuarcy ¦0.002 Abs (0.5Abs)
¦0.004 Abs (1.0Abs)
¦0.006 Abs (2.0Abs)
Photometric repeatability less than ¦0.001 Abs (0.5Abs)
less than ¦0.001 Abs (1Abs)
less than ¦0.003 Abs (2.0Abs)
Baseline stability less than 0.0003 Abs/H @700nm
(one hour after light source turned ON)
Baseline flatness within ¦0.0006 Abs
(190 to 1100nm,one hour after light source turned ON)
Noise level within 0.00005 Abs RMS value (@700nm)
Dimensions (W+D+H) 450(W) x 490(D) x 270(H)
Weight 15kg
Printers DPU, ESC/P, PCL printers, USB I/F Windows-compliant printers are available with USB memory and PC software
Memory USB memory (option) Saved as text and UVPC file
Performance for PC USB memory + UVProbe (standard) Win XP

15 Kg
Fully thermocol packing
Jan-22-09
 
Length=450mm,W=45mm,H=12.7mm
Material:work hardened cold rolled steel
Thickness of material:1.0x1.0x1.2mm;1.2x1.2x1.5mm
Loading capacity:30kgs
Finsh:Electro-zinc plated with clear,yellow or black chromate.

1 set per inner box,10 inner boxes per carton box.
4347 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.