Technical Parameters Product name: PFA reagent bottle Specifications (ml): 30/60/100/125/250/500/1000/2000/3000/4000/5000 Material: PFA Withstand temperature: -196-260 Celsius degree Product Features 1. Translucent appearance; 2. Temperature resistance: operating temperature -200~+260â??; 3. Insulation resistance: dielectric properties have nothing to do with temperature and frequency; 4. Anti-pollution: low metal element value; 5. It has low dissolution and precipitation characteristics and is a container for storing standard substances and different reagents; use: 1. Suitable for storing and packaging different chemical reagents and standard samples; 2. Applicable to semiconductor, polysilicon, photovoltaic electronic lithium battery industries; sampling of high-purity water, electronic pure reagents, photoresist, silicon wafer washing liquid, electronic grade cleaning agent, liquid crystal liquid, circuit board washing liquid, etc.; also suitable for new materials and new Storage and use of energy such as silicon materials; 3. Can be used with Agilent, Shimadzu, PE, Thermo Fisher and other brands of ICP-MS, ICP-OES and other instruments for trace analysis and isotope analysis. Our PFA series products: Sample storage bottles, washing bottles, volumetric flasks, measuring cups, beakers, digestion tubes, sample dissolving tanks, micro columns, crucibles, valves, joints, delivery pipes and other products
In animal husbandry, the technology of artificial insemination through frozen semen has been widely used. As a low-temperature storage container, semen storage tanks are mainly used for the long-term preservation of fine semen or embryos of livestock such as cattle, pigs, and sheep. With the deep low temperature of liquid nitrogen -196�°, the activity of sperm can be maintained for a long time, which is an important tool for artificial insemination and breeding. So, what are the advantages of semen storage tanks? 1. Made of lightweight and durable aluminum alloy, it has good corrosion resistance and oxidation resistance, and can withstand outdoor wind, sun and rain to a certain extent. It is equipped with handles or shoulder straps for easy movement in outdoor environments, especially suitable for outdoor operations such as ranch inspections and on-site semen collection. 2. The multi-layer vacuum insulation design effectively isolates external heat, minimizes the natural evaporation of liquid nitrogen, and ensures the stability of the low-temperature environment inside the container. â?? 3. Equipped with special buckets for storing semen tubes and embryo cryopreservation tubes, it is convenient for sample classification, sorting and extraction to meet the needs of animal breeding. â?? 4. Considering the usage scenarios of users in pastures or mountainous areas, the liquid nitrogen tank may be subjected to shock or vibration during sampling, handling, and transportation. The liquid nitrogen tank is equipped with a protective cover to prevent bumps during use. â?? Therefore, the livestock semen storage tank provides good portability, a safe and stable low-temperature environment, etc. through its design features and material selection, thereby ensuring the quality and activity of semen and meeting the needs of livestock production and research.
Fudau is a professional manufacturer of Erlenmeyer flasks, and here is the product information for our 1000ml Erlenmeyer flask: Height: 216.8mm Neck diameter: 39mm Bottom diameter: 127mm Working Volume: 500ml Material: Polycarbonate (PC) Cap Options: You can choose between a PC flask with a vent cap or a PC flask with a seal cap. Manufacturing Standard: Our products are produced in accordance with the c-GMP (current Good Manufacturing Practices) standard to ensure quality and safety. Cap Material: The bottle cap is made of high-strength HDPE (High-Density Polyethylene) material. Cap Design: The cap is designed with a PTFE (Polytetrafluoroethylene) hydrophobic and breathable membrane. This design ensures that, even after coming into contact with liquids, it won't compromise the sealing and ventilation properties of the breathable membrane. Flask Material: Our Erlenmeyer flasks are made from high-quality polystyrene (PS) raw material, which conforms to USP VI medical grade standards, ensuring the flask's suitability for a wide range of applications.
The 96-well cell culture plate boasts a single well surface area of 0.32 cm², making it an ideal choice for various applications. The recommended operating volume of 0.1-0.2ml/well ensures optimal conditions for cell growth and maintenance. What truly sets Fudau's 96-well cell culture plate apart is the use of high-quality polystyrene (PS) raw material, which conforms to USP VI medical grade standards. This commitment to quality ensures that your experiments are conducted in a safe and controlled environment, free from contaminants that may compromise your results. 96-well cell culture plate is cellular biocompatible, adhering to ISO:10993 standards. This means that it is not only safe for your cells but also maintains the integrity of your experiments. Additionally, each plate is delivered to you in a sterile and endotoxin-free condition, further minimizing any risk of contamination. Whether you are a researcher in a cutting-edge biotechnology company, a scientist in a renowned research laboratory, a medical professional in a hospital, or a dedicated technician in a clinical lab, you understand the pivotal role that cell culture plates play in the experimental process. In pharmaceutical companies, cell culture plates are a fundamental component of drug development and testing. The 96-well format allows for high-throughput screening, enabling the assessment of multiple drug candidates simultaneously. Hospitals and clinical labs employ cell culture plates in diagnostic testing and patient care. These plates are indispensable for culturing patient samples, performing assays, and conducting vital research to advance medical knowledge and patient care.
A 500ml Erlenmeyer flask is crafted from premium borosilicate glass, this flask is resistant to thermal shock and chemical corrosion, ensuring its longevity and performance in demanding laboratory environments. The 500ml capacity makes it ideal for mixing, storing, and heating liquids, offering versatility and convenience for various scientific processes. Features: Dimensions: With a height of 178.8mm, a neck diameter of 39mm, and a bottom diameter of 101mm, this flask boasts ideal dimensions for a variety of laboratory applications. Its design ensures compatibility with a wide array of experimental setups. Working Volume: The flask provides a substantial working volume of 125ml, making it versatile for a multitude of applications. Whether you're growing cell cultures, conducting chemical reactions, or storing samples, this flask accommodates your needs with ease. Cap Options: Fudau understands the significance of a reliable flask cap. We offer two cap options for the 500ml Erlenmeyer flask: the PC flask with vent cap and the PC flask with seal cap. The vent cap facilitates controlled ventilation, while the seal cap ensures airtight integrity for secure sample storage. c-GMP Standard Production: Our commitment to quality is unwavering. The 500ml Erlenmeyer flask is produced in strict adherence to current Good Manufacturing Practices (cGMP), ensuring that it meets the highest standards of quality and reliability. PTFE Hydrophobic and Breathable Membrane: The flask's cap is equipped with a PTFE hydrophobic and breathable membrane, a feature that sets it apart. Even after coming into contact with liquids, the membrane retains its sealing and ventilation properties, ensuring the integrity of your experiments. USP VI Medical Grade Polystyrene (PS): We use high-quality polystyrene (PS) raw material that conforms to the United States Pharmacopeia (USP) VI medical grade standard. This guarantees a contaminant-free environment for your experiments, crucial for Pharmaceutical Companies, Biotechnology Companies, Research Laboratories, Hospitals, and Clinical Labs.
Advantages: 1.Excellent Chemical Resistance: The PFA pipette tips exhibit remarkable chemical stability, resisting corrosion from harsh chemicals like acids, bases, and organic solvents. This ensures consistent performance and accuracy in demanding laboratory environments. 2.Wide Temperature Range: These pipette tips can withstand a broad temperature range from -200�°C to 260�°C, making them suitable for both low- and high-temperature applications. 3.High Precision and Accuracy: The PFA pipette tips offer precise and accurate dispensing of liquids, ensuring consistent and reliable results in laboratory experiments. 4.Low Background Values: With low metal element content (such as lead and uranium) of less than 0.01ppb, these pipette tips are suitable for high-sensitivity analytical techniques like ICP-MS and trace analysis. 5.Customizable Options: The pipette tips are available in different sizes and can be customized to fit various pipette models, meeting the specific needs of different laboratories. Durable and Reusable: The excellent stability of PFA material allows these pipette tips to be used repeatedly over a long period, reducing the need for frequent replacements and saving costs. 6.Easy to Clean: The smooth surface and precise manufacturing of these pipette tips ensure easy cleaning and minimal residue, maintaining the accuracy and reliability of the tips. 7.Transparent and Easy to Observe: The transparent design allows users to easily observe the liquid level inside the pipette tip, making it convenient for accurate dispensing. In summary, the PFA pipette tips from Nanjing Binzhenghong Instrument Co., Ltd. are an excellent choice for laboratories requiring high chemical resistance, precision, and accuracy in liquid handling applications.
Advantages: 1.Material Selection: The inner vessels are crafted using modified polytetrafluoroethylene (TFM), PFA, and PTFE materials, ensuring superior chemical resistance and durability. This choice of materials guarantees a low background value and enhanced performance. 2.Purity and Cleanliness: The vessels are manufactured in a clean environment, without the addition of any recycled materials, ensuring a high level of purity. This results in more accurate and reliable experimental data. 3.Compatibility: These vessels are designed to be fully compatible with various manufacturers' microwave digestion instruments, including CEM models, ensuring seamless integration and operation. 4.Temperature Resistance: The TFM material used in the vessels exhibits excellent resistance to high and low temperatures, ranging from -200°C to +260°C, with a maximum tolerance of up to 300°C. This allows for safe and efficient operation under extreme conditions. 5.Deformation and Permeability Resistance: The TFM material offers improved resistance to deformation and permeation under high temperatures and pressures. This ensures the integrity of the vessel and prevents sample leakage or contamination. 6.Recovery and Durability: The vessels exhibit excellent recovery properties after exposure to high temperatures and pressures, ensuring their long-term durability and reliability. 7.Cost-Effectiveness: While offering comparable or superior performance to original equipment manufacturer vessels, the NJbinglab vessels are priced at a fraction of the cost, significantly reducing expenses for research and scientific institutions. 8.Specialized Production Process: The company employs specialized production processes that ensure a high level of smoothness and cleanliness of the vessel walls. This further enhances the accuracy and reproducibility of experimental results. 9.Customization Options: The company offers customization options, allowing customers to request vessels tailored to their specific needs and requirements. This flexibility ensures that the vessels meet the precise specifications of each application. In summary, the microwave digestion vessels from Nanjing Binzhenghong Instrument Co., Ltd. offer a combination of superior material properties, compatibility, durability, cost-effectiveness, and customization options that make them an excellent choice for scientific and research applications requiring high-performance microwave digestion vessels.
Advantages: 1.Excellent chemical stability: PFA material has extremely low dissolution and precipitation characteristics, which means that when storing and transporting chemicals such as strong acids, strong bases, and organic solvents, the fluid will not be contaminated, thus ensuring the high purity of the fluid. This is critical for applications such as semiconductor manufacturing that require high cleanliness fluids. 2.High temperature resistance: PFA headspace bottles can be used in high temperature environments for a long time without deformation or performance degradation. Its operating temperature range is wide, from -200â?? to +260â??. This characteristic makes PFA headspace bottles widely used in high-temperature processes such as heat treatment and chemical vapor deposition in semiconductor manufacturing. 3.High transparency and visibility: The high transparency of the PFA headspace bottle makes it easy for users to observe the color and state changes of the sample, thus improving the accuracy and reliability of the experiment. 4.Non-adhesive inner wall design: This design reduces sample residue, avoids analysis errors caused by sample adhesion, and improves the accuracy of analysis. 5.Good sealing: The PFA headspace bottle cap has a hole on the top and is equipped with a silicone sheet seal. This design not only facilitates the sampling operation, but also ensures the sealing of the bottle and prevents leakage and contamination of the liquid. 6.Low metal element content: The metal element value of PFA headspace bottles is low, which reduces the deviation of experimental results caused by metal element contamination. It is especially suitable for experimental situations that have strict requirements on metal element content.
1. Product introduction The PFA cleaning tank is an upgraded model after the PTFE cleaning bucket. It is specially designed for semiconductor photovoltaic and other industries. It is formed in one piece, so there is no need to worry about leakage. Mainly used for soaking and cleaning flower baskets or wafer cassettes with chip silicon cells. Due to the characteristics of PFA, it can withstand the corrosiveness of cleaning solutions. At the same time, it has a low blank value of metal elements, no dissolution or precipitation, and will not contaminate chip wafers. Other names: anti-corrosion tank, pickling tank, overflow tank, pure water tank, soaking tank, water tank, drip tank Tank capacity: 15L External dimensions: 300*210*240mm Lid: 340*240*45mm Tank capacity: 18L External dimensions: 390*280*205mm Lid: 400*300*42mm Semiconductor wafer cleaning tank size can be customized as required. It also comes with the same PFA lid to prevent contamination. 2. Features: 1. The appearance is translucent, making it easy to observe the reagents in the tank; 2. High and low temperature resistance: -200ï½?+260â?? 3. Corrosion resistance: resistant to strong acid, strong alkali, aqua regia, HF and various organic solvents; 4. Insulation resistance: dielectric properties have nothing to do with temperature and frequency; 5. Anti-pollution: The background value is low, and the content of lead and uranium of metal elements is less than 0.01ppb; 6. No dissolution or precipitation, and will not pollute chips, wafers, silicon wafers, etc.; 8. Stable chemical properties, good recoverability, and not easy to deform; 9. Teflon plastic, durable and not fragile.
The PFA (Perfluoroalkoxy) distillation and condensation apparatus boasts an array of exceptional advantages and finds widespread applications across various industries. Here's a detailed description of its merits and uses in English: Advantages of PFA Distillation and Condensation apparatus 1.Outstanding Corrosion Resistance: PFA, a high-performance fluoropolymer, exhibits remarkable resistance to corrosive chemicals, including strong acids, bases, and oxidants like hydrofluoric acid (HF). This ensures long-term stability and reliability in harsh environments. 2.Excellent High-Temperature Performance: With a temperature tolerance range spanning from -200�°C to 260�°C, PFA material allows the distillation and condensation apparatus to withstand high temperatures encountered during various processes, ensuring efficient operation. 3.Chemical Inertness and Purity: PFA's extreme chemical inertness prevents reactions with most chemicals, guaranteeing no contamination or impurities in the distilled product. This feature is crucial for high-purity applications like semiconductor manufacturing and pharmaceutical production. 4.Sealability and Safety: The excellent sealing properties of PFA prevent leaks, enhancing process safety and minimizing environmental risks. This is especially important when handling hazardous chemicals like HF. 5.Efficient Heat Transfer and Condensation: The PFA condenser's efficient heat transfer capabilities facilitate rapid cooling of vapors, enhancing distillation efficiency and product purity. 6.Easy Maintenance and Cleaning: PFA's smooth surface resists adhesion of impurities, simplifying cleaning and maintenance procedures, thereby extending the apparatus's lifespan. 7.Environmental Friendliness: By enabling efficient recovery and reuse of chemicals like HF, the apparatus contributes to reduced waste and environmental pollution.
PFA purification system: 1. Product introduction: Acid purifier: also known as acid purification system, high-purity acid purifier, acid reagent purifier, high-purity acid distillation purifier, etc. In laboratory work, the purity of the acid is often poor, causing deviations and errors in the analysis results. Commercially available pure acids are often expensive and difficult to meet the large demand for acids in daily analyses. Therefore, purifying and optimizing the quality of acid is an economically feasible way. Our acid purifier can be used in laboratories to purify HNO3, HCl, HF, alkali solutions and organic solvents. After purification, the purity of the acid is further improved. Later in the experiment, our unit's Teflon series reagent bottles can be used to collect high-purity acid. 2. Working principle: The acid purifier uses the principle of thermal radiation to keep the liquid temperature below the boiling point to evaporate, and then condenses the acid vapor to prepare high-purity water and high-purity reagents. It is widely used in sample processing and analysis experiments. 3. Product features: 1. It can meet the low detection limit requirements of ICP and ICP-MS and provide laboratory-grade ultrapure acid for demanding analysis applications. All containers used are made of Teflon corrosion-resistant non-adsorption plastic and can handle laboratories such as HNO3, HCl, HF, etc. Commonly used acids. 2. Experiments have proven that after a single distillation of an acid with a metal impurity content of about 10 ppb, the metal impurity content can be reduced to about 0.01 ppb. If the acid requirements are higher, the purification times can be increased.
PFA, also known as soluble polytetrafluoroethylene or Teflon, is used for trace analysis, isotope detection, ICP-MS/OES/AAS analysis, and other experiments. The temperature resistance range of PFA bottle washing is very wide, and it can withstand temperatures from -200 to+260 , which means it can be used under various experimental conditions without being limited by temperature. The PFA bottle washing tube and body are reliably sealed, with sensitive spraying performance, fast recovery, and no residue left. It can be sprayed into various container positions, making cleaning very convenient. Therefore, using PFA bottle washing can make experiments more convenient. In addition, the nozzle and cap of PFA bottle washing are formed in one go, and its structure is very tight, so there will be no leakage. This is crucial for the accuracy of the experiment. PFA bottle washing can also replace volumetric flasks to prepare standard solutions, which can be controlled to add samples and water dropwise. This means that using PFA bottle washing can conduct experiments more accurately and reduce errors. Suitable for industries such as semiconductors, photovoltaics, biopharmaceuticals, and petrochemicals. Product features 1. Translucent appearance; 2. Temperature resistance -200+260; 3. The pipe and the body are sealed reliably, the spray ability is sensitive, the recovery is fast, and no residue flows out. It can be sprayed into the position of each container and is easy to clean; 4. The nozzle and bottle cap are formed at one time; 5. It can replace the volumetric flask to configure the standard solution: it can be controlled to add sample and water drop by drop.
Advantages of PFA Volumetric Flasks: 1.Superior Chemical Stability and Corrosion Resistance: Made from high-purity imported experimental-grade PFA material, these flasks exhibit outstanding resistance to a wide range of chemical reagents, including strong acids, bases, aqua regia, and various organic solvents. This ensures the integrity of the flask and prevents contamination of samples. 2.High Temperature Tolerance: Capable of withstanding temperatures ranging from -200�°C to +260�°C, the PFA volumetric flasks are suitable for various high-temperature experiments and industrial applications. However, it is recommended not to use them directly as heating vessels to protect the calibrated markings. 3.Excellent Transparency and Easy Observation: The flasks feature a highly transparent body, allowing for clear visibility of the liquid inside. This facilitates accurate monitoring of experimental progress and facilitates precise volume measurements. 4.Precision Calibration and Accuracy: Each flask is calibrated with laser-etched markings and verified using a precision electronic balance to ensure A-grade accuracy, complying with DIN EN ISO 1042 standards. This ensures reliable and repeatable results across various experiments. 5.Smooth Surface and Easy Cleaning: The smooth interior and exterior surfaces of the flasks prevent sample adhesion and make cleaning a breeze. This facilitates reusability and ensures hygiene between experiments. 6.Tight Sealing and Leak-Proof Design: Equipped with screw caps and thread seals, the flasks prevent sample contamination and leakage, ensuring the integrity of the stored solutions. 7.Low Background and Low Leaching: The PFA material exhibits low background and leaching characteristics, making it ideal for trace analysis experiments such as ICP-MS and ICP-OES, where even minute impurities can affect results.
The graphite digestion system from Nanjing Binzhenghong instrument Co., Ltd. boasts numerous advantages that make it a top choice for various laboratory applications. Here are some of its key benefits: Advantages: 1.High Thermal Efficiency: The graphite digestion system utilizes graphite as its heating element, which offers excellent thermal conductivity and even heat distribution. This ensures rapid and uniform heating of samples, improving digestion efficiency. 2.Excellent Temperature Control: The system is equipped with precise temperature control systems that allow for accurate temperature adjustments and stable operation. This ensures that samples are digested at optimal temperatures, minimizing the risk of over- or under-digestion. 3.Versatility: The graphite digestion system is designed to handle a wide range of sample types and volumes. It can be used for digesting solid, liquid samples, making it a versatile tool for various analytical applications. 4.Ease of Operation: The system's user-friendly interface and intuitive controls simplify the operation process. Users can easily set parameters, monitor digestion progress, and retrieve results, all with minimal training. 5.Durability and Longevity: The use of high-quality materials and components in the construction of the graphite digestion system ensures its durability and longevity. It can withstand frequent use and rigorous laboratory conditions, providing reliable performance over extended periods. 6.Environmentally Friendly: The graphite digestion system contributes to a greener laboratory environment by reducing the use of hazardous chemicals and reagents. It also helps minimize waste generation and energy consumption. In summary, the graphite digestion system from Nanjing Binzhenghong instrument Co., Ltd. offers superior performance, versatility, ease of operation, safety, durability, and environmental friendliness, making it an excellent choice for laboratories seeking reliable and efficient sample digestion solutions.
The NJbinglab PFA Vial Cleaning System offers numerous advantages that make it a preferred choice for laboratories and research facilities. Here are some of the key benefits of this system: Advantages: 1.High Efficiency: The NJbinglab Vial Cleaning System is designed to clean a large number of vials quickly and efficiently. This helps save time and resources, enabling laboratories to focus on more important tasks. 2.Excellent Cleaning Quality: The system ensures thorough and consistent cleaning of vials, removing even the toughest residues and contaminants. This ensures that vials are ready for use without any risk of cross-contamination. 3.Automated Operation: The NJbinglab Vial Cleaning System offers an automated process that reduces the need for manual handling. This not only saves time but also minimizes the risk of human error and contamination. 4.Flexibility: The system can be customized to accommodate different sizes and types of vials, making it a versatile solution for various applications. 5.Safe Operation: Safety is a top priority in the NJbinglab Vial Cleaning System. It incorporates features such as enclosed cleaning chambers to minimize exposure to hazardous chemicals. 6.Eco-Friendly: The system uses efficient water and chemical consumption, minimizing waste and reducing the impact on the environment. 7.Cost-Effective: While the initial investment in the NJbinglab Vial Cleaning System may be higher than traditional manual cleaning methods, the long-term savings in terms of time, labor, and consumables make it a cost-effective solution. 8.Compliance with Standards: The NJbinglab Vial Cleaning System is designed to meet or exceed industry standards for cleanliness and contamination control, ensuring compliance with regulatory requirements. In summary, the NJbinglab Vial Cleaning System offers a comprehensive solution for efficient, safe, and cost-effective vial cleaning, making it an invaluable asset for laboratories and research facilities.
Philips FD 20 10 CATH LAB Year: 2012 Software version: 7/2/16 Tube year: 2011
The NJbinglab PFA (Perfluoroalkoxy) beakers offer numerous advantages that make them a popular choice in laboratories worldwide. Here are some key benefits of these beakers in English: 1.Extreme Chemical Resistance: NJbinglab PFA beakers are made from a material that exhibits exceptional chemical resistance, resisting virtually all chemicals. This ensures that the beakers will not be affected by harsh chemicals, preserving their integrity and safety for long-term use. 2.Broad Temperature Range: These beakers can withstand temperatures ranging from -200�°C to +260�°C, making them suitable for a wide variety of experimental conditions. Whether you're working with cryogenic materials or performing high-temperature reactions, NJbinglab PFA beakers are ready to handle the heat. 3.Durable and Lightweight: Despite their robustness, NJbinglab PFA beakers are lightweight and easy to handle. This makes them convenient to use, even for large-volume applications. Easy-to-Read Graduations: The beakers feature raised graduations that are easy to read, even from a distance. This allows for precise measurement of liquid volumes, ensuring the accuracy of your experimental results. 4.Low Leaching Potential: The PFA material used in these beakers has a low leaching potential, meaning it is unlikely to contaminate your samples. This is especially important for sensitive applications where cross-contamination could compromise results. 5.Autoclavable and Sterilizable: NJbinglab PFA beakers can be autoclaved or sterilized using high-temperature methods, ensuring they are ready for sterile applications. This makes them a valuable tool in research labs and clinical settings. In summary, NJbinglab PFA beakers offer an unparalleled combination of chemical resistance, temperature tolerance, durability, and convenience. These features make them a trusted choice for laboratories around the world.
PFA and PTFE materials are widely used in the production of distillation & rectification apparatus due to their unique physical and chemical properties. The following are the advantages and applications of distillation & rectification apparatus made of these two materials: Advantages 1. Corrosion resistance: Both PFA and PTFE have extremely strong corrosion resistance and can resist the erosion of a variety of strong acids, strong bases, organic solvents and oxidants. This makes them perform well when handling corrosive substances and can ensure the stability and safety of the distillation & rectification process. 2. High temperature resistance: Both can maintain stable performance in high temperature environments. The operating temperature range of PTFE can reach -200â?? to +250â??, while PFA can reach -200â?? to +260â??, which makes them suitable for high-temperature distillation & rectification processes. 3. Good sealing performance: Distillation & rectification apparatus made of PFA and PTFE materials usually have excellent sealing performance, which can effectively prevent leakage problems in the distillation process and improve distillation efficiency and product quality. 4. No pollution: When these two materials come into contact with high-purity chemical reagents, there is almost no dissolution of impurities, which can maintain the purity of the product and is suitable for fields with extremely high purity requirements. 5. Easy processing: We are a factory that supports customization. PFA and PTFE materials are very flexible in the design and manufacture of distillation & rectification apparatus.
Hitachi Aperto Inspire 2007y Software Version-V3.0, Coils-Flexible Body(L), Flexible Body(M), QD Wrist, QD Head, Joint(L), Joint(M).
Toshiba Infinix VF-I/SP CLB YOM: 2013 Serial: E6D13X2042 Tube YOM: 2024 - was changed last week Detector: Original (30x30) Service: Full OEM since installation It was installed in 2013 but upgraded in 2017.