Pipette Tips are consumables commonly used in chemistry,biology,medicine to transport a measured volume of liquid.It has many types and specifications,transparent or black,with or without filter,max volume can be from 10ul to 1250ul. We produce the pipette tips in 100,000 grade cleaning room.So the tips we have are DNAse, RNAse free and sterilized.
3-part blood cell counter 20 parameters + 3 histograms 2 counting channels Up to 60 samples/hour 10.4â?³ large color LCD Built-in printer, USB port Stable, durable and economical
Feature: 7 inch Color LCD , Touch screen Flow cell and Cuvette test mode compatible Real time curve showing 7 wavelength , 90 test item pre-programmed Memory for 10,000 sample results Light source hibernate function making lamp life longer RS232 interface, PC connecting Test mode: Kinetic, End point, Two point, Absorbance
Clear, Transparent & Flexible built in air vent Chamber. Super smooth kink resistance tube. Very Efficient roller controller for accurate flow rate. Latex / Latex Free Tube for flushing. Needle size G: 18. Sterile / Disposable / Individual Packed.
Rochon Polarizers Rochon polarizer is made of two birefringent material prisms cemented or optically contacted together. The Rochon prism was invented by and is named after Abb Alexis Marie Rochon. It is in many ways similar to the Wollaston prism, but the ordinary ray passes through the prism undeviated. Any separation angle can be designed according to request of customers. Features Multiple Polarization Materials Available Ordinary Rays Pass Through Undeviated Extraordinary Rays Deviate Photonchina Specifications Material: a-BBO, Calcite, YVO4,Quartz,MgF2 Wavelength Range: a-BBO 190-3500nm,YVO4 500-4000nm Quartz 200-2300nm Calcite:350-2300nm Extinction Ratio: Quartz
Glan Taylor polarizer is made of two birefringent prisms that are assembled with an air space. The polarizer with no side escape windows is suitable for low to medium power application where the side rejected beams are not required. Photonchina Featureï¼? Air-spaced Close to Brewster's Angle Cutting High Polarization Purity Short Length Wide Wavelength Range Suitable for low to medium power application 1. Calcite Glan Taylor Polarizer C.A. fa(mm) O.D. fd(mm) L �¯0.1(mm) 6.0 15.0 15.0 8.0 25.4 17.0 10.0 25.4 19.0 15.0 30.0 23.0 20.0 38.0 29.0 2. a-BBO Glan Taylor Polarizer C.A. fa(mm) O.D. fd(mm) L�¯0.1(mm) 6.0 15.0 15.0 8.0 25.4 17.0 10.0 25.4 19.0 15.0 30.0 23.0 20.0 38.0 29.0 3. YVO4 Glan Taylor Polarizer C.A. fa(mm) O.D. fd(mm) L 0.1(mm) 6.0 15.0 12.0 8.0 25.4 15.0 10.0 25.4 17.0 15.0 30.0 20.0 20.0 38.0 25.0
Standard: BS 1377/1924, ASTM D558/698/, AASHTO T99/T134, EN 13286-2
Product Introduction WFLC-VI Portable Waveform Recorder is a portable device based on the structure of an industrial portable computer. It takes high-performance DSP high-precision ADC chip and embedded operating system as hardware and software architecture and integrates data acquisition processing transmission storage analysis and other functions as one. DSP acquisition chip for data acquisition and calculation so as to achieve full digital analog signal filtering flexible and diverse sampling frequency from 10K /s 20K /s 50k/s 100K /s can be selected by users can be used for transient electrical signal waveform recording and analysis. With advanced industrial control kernel and embedded operating system users can easily carry out data storage backup analysis output and other operationsã?? WFLC-VI portable waveform recorder is a collection of fault wave record generator characteristic test and other functions in the integration of intelligent instrument with its small size strong function scope of application is wide flexible configuration and many other advantages favored by the masses of users is a power utility workers standing it will be for the electric power industry production and technological progress to make due contributions.
Product Introduction Designed for automatic testing of protective and metrological CT/PT suitable for laboratory and field testing. The product namesï¼?PT volt-ampere characteristic tester transformer volt-ampere characteristic integrated tester CT voltage-current characteristic integrated tester CT voltage-current characteristic tester PT volt-ampere characteristic tester transformer volt-ampere characteristic tester volt-ampere characteristics of variable polarity than integrated tester volt-ampere characteristic tester volt-ampere characteristics integrated tester volt-ampere characteristic tester features comprehensive tester
Compact Ram Presses : Ross & Mount Lab presses provide precise , durable and cost effective performance. This Bench top platen type press is used in sample compression moulding , punching / stenciling , adhesive testing and sheet production . The linear Bearing units on hard chrome plated grounded steel shafts control the platen movements . This provide excellent durability . Tooling can be customized to suit the customer specifications . The day lights can be manually adjustable to suit the optimum operation of the press . Manual Stoppers can be provided to adjust the variable stroke /Day light . The massive platens offers minimum deflections even at full loads .Built into a compact and elegant structure made of steel, treated with epoxy paint. SPECIFICATIONS: LP-500 Platen size : 400 x 400 mm Opening Stroke : 300 mm Max. Clamping force: 50 tonnes Max. Pressure : 180 Bars Hydraulic pump : Piston type Electric Motor : 3 KW Minimum Day light : 150 mm Max. Day Light : 300 mm Dimensions : 1700(L) X 1200 (W) x 1800 (H)
TKDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables. 1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use. 2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
Wide Mouth Bottle, PFA 250mL/500ml PFA Wide Mouth Bottles are ideal for use with aggressive chemicals. Strong, rigid Sterilizable bottles offer excellent chemical resistance. Excellent for large-volume liquid and phenol extractions, digestions and precipitations. Resists most acids, bases and organic solvents Products Description Product Name: wide mouth 250 ml 500ml PFA reagent bottle Color: Translucent Size: 250ml/500ml Temperature resistance: -200~+260 Characteristic: 1.chemical inert 2.translucent, easy to observing the solutions 3.wide mouth 4.non- leachable, ensure the ultra clean background 5.non-stick, easy to clean 6.ultra low trace metal elements. 7.factory with competitive price 8. Smooth internal finish MOQ: 1pc
PFA gas wash bottles Gas wash bottles PFA fluoroplastic labware for reliable analytical results Gas-wash bottles are used, as the name suggests, for washing gases. The gas-wash bottle is connected to a gas flow and filled with a liquid, depending on. The gas is introduced into the liquid via a tube and is thus cleaned of contamination. Depending on the selected liquid a humidification (with water), drying (with concentrated sulphuric acid) or a targeted separation can take place.The purified gas is evacuated via a second tube from the gas-wash bottle. Specification:100/250/500/1000ml It is an economical device for precipitation material from gas, with porosity dispersion disk, FEP stopper has inlet and outlet ports for gas Products Description Product Name: PFA gas wash bottles Color: Translucent Size: 100/250/500/1000ml Temperature resistance: -200~+260 Characteristic: 1. break resistant 2. inert to virtyally all chemicals 3. excellent for long term storage 4. no leachable metals 5. excellent temperature stability 6.non-stick, easy to clean 7.factory with competitive price 8.MOQ is one ,some items are in stock, can dispatch timely MOQ: 1pc
PFA gas wash bottles Gas wash bottles PFA fluoroplastic labware for reliable analytical results Gas-wash bottles are used, as the name suggests, for washing gases. The gas-wash bottle is connected to a gas flow and filled with a liquid, depending on. The gas is introduced into the liquid via a tube and is thus cleaned of contamination. Depending on the selected liquid a humidification (with water), drying (with concentrated sulphuric acid) or a targeted separation can take place.The purified gas is evacuated via a second tube from the gas-wash bottle. Specification:100/250/500/1000ml It is an economical device for precipitation material from gas, with porosity dispersion disk, FEP stopper has inlet and outlet ports for gas Products Description Product Name: PFA gas wash bottles Color: Translucent Size: 100/250/500/1000ml Temperature resistance: -200~+260 Characteristic: 1. break resistant 2. inert to virtyally all chemicals 3. excellent for long term storage 4. no leachable metals 5. excellent temperature stability 6.non-stick, easy to clean 7.factory with competitive price 8.MOQ is one ,some items are in stock, can dispatch timely MOQ: 1pc
Volumetric Flask, 1000mL. These volumetric flasks are highly-transparent, easy-to-clean, and meet Class A tolerances per DIN EN ISO 1042.Flasks are manufactured from virgin PFA , which is highly resistant to heat and chemical contamination. PFA surface properties offer superior cleanability to glass, PTFE and polypropylene containers, reducing risk of sample carryover in trace analysis applications. These beakers are suitable for sterilization using heat, gas, and chemical methods for sensitive biological applications. Screw cap design provides reduced contamination risk, compared to traditional stopper design.
Volumetric Flask, 250mL. Flasks are manufactured from virgin FEP , which is highly resistant to heat and chemical contamination. FEP surface properties offer superior cleanability to glass, PTFE and polypropylene containers, reducing risk of sample carryover in trace analysis applications. These beakers are suitable for sterilization using heat, gas, and chemical methods for sensitive biological applications. Screw cap design provides reduced contamination risk, compared to traditional stopper design. OEM is available, welcome to contact for further details.
Reaction vessel commonly used in biochemical,modern fine chemical,pharmaceutical,scientific experiments and other industries. Custom-made PFA reaction vessel 1. break resistant 2. inert to virtyally all chemicals 3. excellent for long term storage 4. no leachable metals 5. excellent temperature stability 6.non-stick, easy to clean 7.factory with competitive price 8.MOQ is one
Volumetric Flask, 100mL. Flasks are manufactured from virgin FEP , which is highly resistant to heat and chemical contamination. FEP surface properties offer superior cleanability to glass, PTFE and polypropylene containers, reducing risk of sample carryover in trace analysis applications. These beakers are suitable for sterilization using heat, gas, and chemical methods for sensitive biological applications. Screw cap design provides reduced contamination risk, compared to traditional stopper design.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 2 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: High-quality ABS plastic wrap angle. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 5 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: Metal coates high-quality ABS plastic. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.