W3/130 is based on the humidity sensor method and is professionally applicable to the water vapor transmission rate test of film specimens.
Screw Storage caps, septa, and vials are designed especially for use with Agilent's and otherrotating or robotic arm samplers . Storage vials are manufactured of Clear, Type 1 Class A or Amber, Type 1 Class B borosilicate glass . Caps are made of high quality polypropyleneto exact manufacturing tolerances and lined in a controlled manufacturing environment . Our septa only use the highest quality materials to ensure proper function and can be pre-slit to ease needle penetration. Designed for single injection and/or short sample cycles, particularly for LC applications Absence of elastomer layer reduces potential for contamination. Features: Volume/Capacity:� 20ml, 40ml, 60ml (Normal Volume) Feature: 27.5*57mm, 27.5*75mm,27.5*95mm, 27.5*140mm vials, 22*3/22*1.5mm PTFE/Silicone septa, 20mm PP screw cap Qty/Pack: 100/pack z Model:� Storage screw-thread vials
The fiskeâ® 210 micro-sample osmometer The fiskeâ® 210 freezing-point osmometer requires only a 20âµl sample size, which provides accurate osmolality results in less than 90 seconds. For convenience, the fully accessible probe design is easy to clean and service. The 210 is not only your most reliable option, it's the easiest to use. Just pipette 20âµl of sample into a disposable sample tube, then place the tube into the test chamber. Lower the probe into the sample and push the "test" button. Results are displayed in ninety seconds. Features Alphanumeric display: results, user prompts, and instrument diagnostics are clearly displayed. Easy push-button operation: requires minimal operator training. Printer, rs232c and barcode scanner ports: a full range of data handling options is available. Unit connects easily to printer, computer and scanner. Automatic calibration: no fine-tuning or user adjustments during calibration. The instrument's microprocessor automatically makes calibration adjustments at the push of a button. Smallest sample size: only 20âµl of sample needed. Solid-state cooling: the 210 has no liquid cooling bath; no maintenance required.
Achromatic objectives: 4x, 10x, 40x(s), 00x(s, oil) Eyepiece: wide field eyepiece wf10x(wf16x optional) Viewing head: sliding binocular head inclined at 45° , 360° rotatable Stage: double layer mechanical stage size 140x140mm, moving range 75x45mm Focusing: coaxial coarse and fine adjustment, focusing range 30mm, focusing interval 0.002mm Condenser: abbe na=1.25 with lris diaphragm&filter Illumination : led adjustable (halogen lamp optional)
Double-glazed designed glass reactor, the liner is for reaction solvent, and the jacket for heating or cooling resource(cool liquid, hot water or hot oil), to achieve circulating heating or cooling experiment. And its ancillary equipment-high and low temperature machine which can satisfy functional high & low temp reaction experiments.
Fiber optic spectrometer with the advantages of modularization and flexibility of its measuring system is widely used to measure wavelength and line width of laser, LED and common light source, can accurately obtain the spectral characteristics of the light source which is being tested. CNI developed spectrometers with the characteristics of compact and portable design, plug and play, easy operation and Spectral Analysis 5.0 software downloads, which are extensively applied on the fields of scientific research, teaching, industries and many other applications. CNI can also customize the wavelength and resolution of the spectrometers according to different customers’ demands.
Laser power meter is used to measure laser power and power stability. CNI as a world's leading designer and manufacturer of laser system, designed several laser power measurement instruments with the features of accuracy testing, easy operation, etc., which could fully meet customer's practical needs of laser power and power stability measurement. They are widely used in the research, teaching, medical science, industry and other fields.
The finest experimental facilities in the country rely on KC Hydraulic Engineering Labs for accurate analysis and superior precision. Our equipment of Hydraulic Lab explain the principles of bernoulli’s theorem, continuity, momentum and many more concepts that are applied to fluid motion. The Hydraulics Laboratory offers many testing facilities including fluid mechanical, hydraulic machinery, wind tunnel, flow channels and computer-controlled equipment, pumps etc.
We can understand a lot about a process just by observing it. The lab helps the students to study refrigeration and air conditioning systems, their components and processes. The RAC lab should be well-equipped with the experimental setups, models and charts as required in the curriculum. Our Refrigeration & Air Conditioning laboratory equipment are known for their durability and accurate results. KC REFRIGERATION & AIR CONDITIONING LAB Select Quantity
Main Technical Parameter: Model TH-100 TH-225 TH-500 TH-800 TH-1000 Internal dimension (mm) 450*450*500 500*600*750 800*700*900 800*1000*1000 1000*1000*1000 Overall dimension (mm) 1050*880*1440 1050*1020*2000 1320*1320*2170 1470*1520*2315 1670*1520*2315 Technical structure Temperature range -20~+150 Low type : -40 :-60 : -70 Humidity range 20% ~ 98% RH Temperature fluctuations ± 0.5 Temperature deviation ± 2.0 Humidity deviation ± 2.5% RH Heating rate 3 / min Cooling rate 1 / min Control system Controller 5.7" programmable color display touch screen controller Controller optional languages are English, German, French, Russian, Spanish, Korean, Japanese. PC Link with software, R-232 interface Temperature Sensor PTR Platinum Resistance PT100O/MV A-class Temperature Resolution ± 0.001 Humidity sensor Dry and wet bulb sensor Humidity Resolution ± 1%RH Heating system Independent Nichrome electronic heating system Cooling system French TECUMSEH compressor Humidification system External isolation, stainless steel surface evaporation humidifier Dehumidification system Evaporator Water supply system Automatic water supply, Water purification system, Water saving Circulatory system Cold resistance and low noise centrifugal wind wheel Material Exterior material Steel Plate with protective coating Interior material SUS304 stainlesssteel Insulation window Double thermostability silicone rubber sealing Standardconfiguration 1 Cable hole (F 50,) cover, 2 sets of shelf, 2 protector tubes, 1 overflow water tube,1 copy of operating specification Timing Function 0.1~999.9 (S,M,H) settable Power Supply AC220V/AC380V 50HZ Three-phase five little system Ambient Temperature 5~+30 =85% RH Standard IEC60068-2-1;IEC60068-2-2;GB/T2423.1-2001; GB/T2423.2-2001
Pathological and diagnostic solutions .
Specialty Adhesives, Digital Moisture Meter..
General lab equipments, laboratory medical consumables.
Lab furniture and equipment.
IVD products, rapid test, elisa kit, laboratory plastic consumables.
Antibodies, viral antigens, innovative diagnostic components, and critical assay reagents .
Laboratory glasswares and chemicals.
Product Features: 1. Pure white PTFE 2. Temperature range: -200 to 250 degrees Celsius; 4. Low background value; 5. Good chemical resistance, can withstand most chemical solvents (strong acid, strong alkali, aqua regia and various organic solvents); As a high-quality, high-performance new material carrier, Teflon silicon wafer carrier is widely used in various fields, such as semiconductor manufacturing, electronics industry, medical treatment, etc. Its special structure gives it good mechanical properties, high temperature resistance and chemical stability, so that it can reliably support and protect various complex electronic components. Compared with traditional carriers, PTFE silicon wafer carriers have higher strength and better corrosion resistance, can maintain stability in extreme environments, and will not be affected by substances such as water, oil, acid and alkali. At the same time, it can also work for a long time at high temperature without deformation or damage.
Product name: PFA multi-neck flask Specifications (ml): 250/500/1000/2000/3000 Material: PFA Using temperature: -200-260 Pressure tolerance: Maximum 0.05Mpa When fabricating flasks with PFA (Perfluoroalkoxy), there are numerous advantages that make it an excellent choice for various applications. Here are some of the key benefits and industries where PFA flasks are commonly used: Advantages: Advantages of PFA flasks: 1.Excellent Thermal Stability: PFA flasks possess outstanding heat resistance, enabling them to withstand temperatures ranging from -200�°C to +260�°C. This thermal stability is crucial for many high-temperature experiments, such as heating reactions, boiling, and high-temperature solvent extraction. 2.Superior Transparency: PFA flasks exhibit excellent transparency, allowing for clear observation of reaction processes and sample changes. This is crucial for monitoring and recording reactions in chemical experiments, enabling researchers to better understand and analyze the progress and results. 3.Anti-Adhesion Properties: PFA flasks have good anti-adhesion properties, meaning reagents are less likely to adhere to the inner walls. This reduces loss and waste, while maintaining the cleanliness of the flask's interior and preventing any potential contamination from adhering substances. 4.Excellent Electrical Properties: PFA flasks are excellent electrical insulators, effectively isolating electrical currents and reducing interference from electrochemical reactions. 5.Good Mechanical Properties: PFA flasks possess good mechanical strength and abrasion resistance, enabling them to withstand high pressures and impacts.
1. Product Introduction Microwave digestion systems have been widely used in food, medicine, textiles, plastics, geology, metallurgy, coal, biomedicine, petrochemicals, environmental monitoring, sewage treatment, cosmetics and other fields. Our factory can provide various manufacturers and models of microwave digestion system inner vessels and related racks, turntables, plugs and gaskets. HVT50 microwave digestion vessel is suitable for Austrian AntonPaar Multiwave GO type microwave digestion system. The parts of this microwave digestion vessel are item numbers, lid: 104453, plug: 104454, vessel: 104616 2. Product parameters Item number: lid: 104453, plug: 104454, vessel: 104616 Applicable instrument: AntonPaar Multiwave GO type microwave digestion instrument 24-bit Inner vessel material: modified polytetrafluoroethylene material (TFM) High and low temperature resistance: -200ï½?+260â??, the maximum resistance is 300â?? Specifications: 50ml III. The outstanding features of the inner vessel of the microwave digestion instrument we produce 1. The inner vessel is made of modified polytetrafluoroethylene (TFM) material; 2. Selected materials, no recycled materials added, clean processing environment, optimized processing technology, and low background; 3. TFM temperature resistance -200 ~ +260 â??, the maximum resistance is 300 â??. It has the characteristics of low background value, good deformation resistance, penetration resistance, and stronger recovery under high temperature and high pressure; 4. The experimental data is not inferior to the original factory, and the cost is low, which greatly reduces the cost of purchasing consumables for many scientific research units; 5. The inner vessel can be equipped with our factory's acid-driving electric heating plate as an acid-driving tool in the later stage of the experiment.