Measuring Range:
-20~+20D(VD = 12,0.12D / 25D STEPS) -10~+10D (0.12D/25D STEPS) 1~180 ( 1 STEPS )
Pupil Distance:
30~85mm, 1mm STEPS
Vertex Distance:
0mm, 12mm, 13.75mm , 15mm
Min.Pupil Size:
2.0mm
Chart:
AUTO FOG
Display:
5.7TFT LCD
Print:
THERMAL PRINTER
Power Supply:
100~120V / 200~240V, 50 / 60Hz
Dimensions:
480 (L) X 270(w) x 445 (H) mm-mm-mm
Weight:
17 KG
Features:
1. PUPIL DISTANCE AUTO MEASURED
2. WITH AUTO - TRACING FEATURE , OPEREATER CAN ADJUST THE FOCUS AND ALIGNMENT IN UP AND DOWN DIRECTIONS
3. WITH AUTO VIDEO TAPING FEATURE , OPERATOR CAN TAKE MEASUREMENTS AUTOMATICALLY ONCE EQUIPMENT OBTAINS SATISFACTORY FOCUS AND ALIGNMENT
4. WITH SERVO CHIN-REST , OPERATOR CAN ADJUST HEIGHT OF CHIN-REST EASILY
5. DISPLAY IS TILT - ADJUSTABLE
6. PRINTER HAS A PAPER AUTO CUT
WARRANTY:
1 YEAR
TAGLINES:
1. 5.7' LCD TILTABLE COLOR DISPLAY
2. PRINTER WITH AUTO CUTTING
3. PD MEASUREMENT
4. AUTO FOG CHART
5. VERTEX DISTANCE
6. AUTO CHIN-UP AND DOWN
7. AUTO ALIGN AND FOCUS
W3/330 system is based on the electrolytic sensor method to measure water vapor transmission rate of film and package specimens. It has three independent testing cells and can be easily connected with 9 satellite systems.
Benefits :
Increase sample throughput
Available for high barrier materials
Simulate some realistic application of packaging conditions in the market
TSY-W3 is professionally applicable to determination of water vapor permeability of plastic films, high barrier materials, back-sheets, sheeting, aluminum foils, waterproof materials, and other materials used in sanitary and medical industry.
W3/230 is based on the infrared sensor method and designed for the determination of water vapor transmission rate of film and package specimens. It is applicable to various materials with high, medium and low water vapor permeability.
Benefits :
Increase sample throughput
Available for high barrier materials
Simulate some realistic application of packaging condit ions in the market
4349 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
Screw Storage caps, septa, and vials are designed especially for use with Agilent's and otherrotating or robotic arm samplers .
Storage vials are manufactured of Clear, Type 1 Class A or Amber, Type 1 Class B borosilicate glass .
Caps are made of high quality polypropyleneto exact manufacturing tolerances and lined in a controlled manufacturing environment .
Our septa only use the highest quality materials to ensure proper function and can be pre-slit to ease needle penetration.
Designed for single injection and/or short sample cycles, particularly for LC applications
Absence of elastomer layer reduces potential for contamination.
Features:
Volume/Capacity:� 20ml, 40ml, 60ml (Normal Volume)
Feature: 27.5*57mm, 27.5*75mm,27.5*95mm, 27.5*140mm vials, 22*3/22*1.5mm
PTFE/Silicone septa, 20mm PP screw cap
Qty/Pack: 100/pack z
Model:� Storage screw-thread vials
The fiskeâ® 210 freezing-point osmometer requires only a 20âµl sample size, which provides accurate osmolality results in less than 90 seconds. For convenience, the fully accessible probe design is easy to clean and service. The 210 is not only your most reliable option, it's the easiest to use. Just pipette 20âµl of sample into a disposable sample tube, then place the tube into the test chamber. Lower the probe into the sample and push the "test" button. Results are displayed in ninety seconds.
Features
Alphanumeric display: results, user prompts, and instrument diagnostics are clearly displayed.
Easy push-button operation: requires minimal operator training.
Printer, rs232c and barcode scanner ports: a full range of data handling options is available. Unit connects easily to printer, computer and scanner.
Automatic calibration: no fine-tuning or user adjustments during calibration. The instrument's microprocessor automatically makes calibration adjustments at the push of a button.
Smallest sample size: only 20âµl of sample needed.
Solid-state cooling: the 210 has no liquid cooling bath; no maintenance required.
Double-glazed designed glass reactor, the liner is for reaction solvent, and the jacket for heating or cooling resource(cool liquid, hot water or hot oil), to achieve circulating heating or cooling experiment. And its ancillary equipment-high and low temperature machine which can satisfy functional high & low temp reaction experiments.
Fiber optic spectrometer with the advantages of modularization and flexibility of its measuring system is widely used to measure wavelength and line width of laser, LED and common light source, can accurately obtain the spectral characteristics of the light source which is being tested. CNI developed spectrometers with the characteristics of compact and portable design, plug and play, easy operation and Spectral Analysis 5.0 software downloads, which are extensively applied on the fields of scientific research, teaching, industries and many other applications. CNI can also customize the wavelength and resolution of the spectrometers according to different customers’ demands.
Laser power meter is used to measure laser power and power stability. CNI as a world's leading designer and manufacturer of laser system, designed several laser power measurement instruments with the features of accuracy testing, easy operation, etc., which could fully meet customer's practical needs of laser power and power stability measurement. They are widely used in the research, teaching, medical science, industry and other fields.
The finest experimental facilities in the country rely on KC Hydraulic Engineering Labs for accurate analysis and superior precision. Our equipment of Hydraulic Lab explain the principles of bernoulli’s theorem, continuity, momentum and many more concepts that are applied to fluid motion. The Hydraulics Laboratory offers many testing facilities including fluid mechanical, hydraulic machinery, wind tunnel, flow channels and computer-controlled equipment, pumps etc.
We can understand a lot about a process just by observing it. The lab helps the students to study refrigeration and air conditioning systems, their components and processes. The RAC lab should be well-equipped with the experimental setups, models and charts as required in the curriculum. Our Refrigeration & Air Conditioning laboratory equipment are known for their durability and accurate results. KC REFRIGERATION & AIR CONDITIONING LAB Select Quantity
Model TH-100 TH-225 TH-500 TH-800 TH-1000
Internal dimension (mm) 450*450*500 500*600*750 800*700*900 800*1000*1000 1000*1000*1000
Overall dimension (mm) 1050*880*1440 1050*1020*2000 1320*1320*2170 1470*1520*2315 1670*1520*2315
Technical structure
Temperature range -20~+150
Low type : -40 :-60 : -70
Humidity range 20% ~ 98% RH
Temperature fluctuations ± 0.5
Temperature deviation ± 2.0
Humidity deviation ± 2.5% RH
Heating rate 3 / min
Cooling rate 1 / min
Control system
Controller 5.7" programmable color display touch screen controller
Controller optional languages are English,
German, French, Russian, Spanish, Korean, Japanese.
PC Link with software, R-232 interface
Temperature Sensor PTR Platinum Resistance PT100O/MV A-class
Temperature Resolution ± 0.001
Humidity sensor Dry and wet bulb sensor
Humidity Resolution ± 1%RH
Heating system Independent Nichrome electronic heating system
Cooling system French TECUMSEH compressor
Humidification system External isolation, stainless steel surface evaporation humidifier
Dehumidification system Evaporator
Water supply system Automatic water supply, Water purification system, Water saving
Circulatory system Cold resistance and low noise centrifugal wind wheel
Material
Exterior material Steel Plate with protective coating
Interior material SUS304 stainlesssteel
Insulation window Double thermostability silicone rubber sealing
Standardconfiguration 1 Cable hole (F 50,) cover, 2 sets of shelf,
2 protector tubes, 1 overflow water tube,1 copy of operating specification
Timing Function 0.1~999.9 (S,M,H) settable
Power Supply AC220V/AC380V 50HZ Three-phase five little system
Ambient Temperature 5~+30 =85% RH
Standard IEC60068-2-1;IEC60068-2-2;GB/T2423.1-2001; GB/T2423.2-2001