Digital Auto Melting Point Apparatus Up to 300C, Suitable for Melting / Boiling Point, Readability in C, Resolution 1C, Programmable, Visual provision by Optical Magnifier, Automatic Ramp Rate Proceeding, Auto Gradient Rate of Heating Control, Sample Capacity 3 samples. The unit consists of a built-in magnetic stirrer, glare free background illuminator and cylindrical silicon oil bath. The silicon oil bath consists of a plain cylindrical container of corning glass having capacity of about 200 ml.
Features:-
Melting View Magnifying display of melting operation with the help of adjustable magnifying glass
Melting point reading hold on by activating the HOLD key & reading is protected from power failure till RESET is not activated.
Technical Specification:-
Model
S- 972
Temp. Range
Ambient to 300C
Display
4 Digit
Resolution
1C, (0.1C Optional)
Temp. Sensor
Grade PT-100, Platinum Sensor
Sample Capacity
3 samples and one 8mm provision for test tube, for the determination of boiling point of any liquid
Application Area
Silicon oil bath (Made of high-temp. toughened glass)
Application
Suitable for boiling & Melting Point
Melting View
Magnifying display of melting operation with the help of adjustable magnifying glass, melting point reading hold on by activating the HOLD key & reading is protected from power failure till RESET is not activated.
Heating Control
Microprocessor Controlled closed loop PID
Ramp Rates
2C to 10C/minute (Selectable auto-low-high)
Advanced visible spectrophotometer offering superior accuracy and resolution for quantitative analysis of samples
Large sample chamber can accommodate 5-100mm path length cuvettes.
Quantitative and Kinetics test with professional PC software.
Automatically adjust 0%A and 100%T.
Store 50 groups of measuring data.
70 x 40mm blue light LCD display.
Manual wavelength setting.
Photometric Mode - T, A, C.
PC software available
Precisely measure the absorbance of light in the visible spectrum with our high-performance visible spectrophotometer. Ideal for applications in chemistry, biology, and materials science.
4LCD Display.
RS232C Interface.
Measured values can be transferred to PC via RS232C port  for further analysis with software.
PC software available.
Wavelength can be set manually from the dial on the front panel.
Photometric Mode - T, A, C
Technical Specifications
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Range - 330-1020 nm
Spectral Bandwidth - 5 nm
Wavelength Accuracy :-± 2nm
Wavelength Repeatability-Â + 1nm
Photometric Accuracy - 0.5%T
Photometric Repeatability- + 0.2%T
Photometric Mode- T, A, C
Stray Light& Stability : 0.3%T & + 0.002A
Wavelength Setting : Manual
Display : 4" LCD
Light Source : Tungsten Lamp
Detector& Cell Holder-Â Silicon Photodiode& 4 position 10mm cell holder
Powersupply -Â AC 220V/50Hz
Packing Dimension -Â (LxWxH) 520 x 450 x 320mm
Gross Weight : 9kg
Discover the UV-VIS Single Beam Spectrophotometer, your essential tool for precise measurements in the ultraviolet and visible spectrum. Analyze absorbance, transmittance, and concentration with ease. Ideal for research, education, and quality control.
Unique optical system, 1200 lines/mm grating.
The instrument has basic functions of photometric analysis and quantitative analysis.
It expands the applications, such as spectral scanning, kinetics, DNA/protein analysis, multi-wavelength test, etc. with PC software.
Store 200 test data and 100 standard curves;
Deuterium and Tungsten lamp can ON / OFF individually to increase the shelf life.
Large sample chamber can accommodate 5-100mm cuvettes.
Photometric Mode - T, A, C, E.
PC software available
1. Full wavelength scanning (190-1100nm) covers UV, Vis. near IR.
2. Fully sealed structure, all optical mirrors are equipped with SiO2 protective film to avoid stray light caused by dust and corrosive gas.
3. Core components reduce the stray light and improve the stability and reliability.
4. Double beam optical system with precision vertical-type dual optical path and dual detector.
5. Grating of high performance greatly reduces the stray light and improves the stability and reliability of device.Ã?Â
6. 10 inches large touch screen, built-in 32GB memory.
7. Powerful data analysis system with internal computer could realize multi functions independently. Like establishing calibration curve, photometric measurement, quantitative measurement, spectral scanning, dynamics, DNA/Protein test, multi-wavelength analysis and data printing.
8.� � W Lamp / D2 Lamp can monitor of usage hours.
9. Data can export in Pendrive directly
10. Convenient data storage and printing function. LUV Series can be directly connected to the printer HP DESKJET 2723 for A4 paper data and graph printing.
11. Automatic power ON self test and system positioning function could inspect and calibrate the deviation before every use.Ã?Â
12. All test data and analysis report can be exported to USB disk directly.
13. Graphs support 3D display,
14. PC software follows GLP & GMP standards, user management, logging, data tracking, etc. mostly as per 21CFR Part 11.
1. Analog Model with fixed current 250mA and also 5 types of fixed voltage means 50V. 100V. 150V. 200V and 250V.
2. It is recommended for mini Horizontal and mini vertical Electrophoresis Apparatus.
3. The voltage is selected thru a 5 step voltage regulator. Example if selector swich is at 1 position. The LED light will glow at 50 V means fixed voltage of 50V is selected. Like wise other voltage can be selected.
It is required in biotechnology and molecular biology applications in colleges. universities research institutes.
It meant for protein characterization.
The buffer chamber is jointless, moulded of transparent polycarbonate to avoid leakage. The unit is based on acrylic sheet fitted with 3 leveling screws.
Complete with acrylic cover.
Technical Parameter.
4 dimensions (Outer) (LxWxH) 15x18x15 cm
4 Gel Size (cm) 8cx7 ) Gel
4 Buffer required (ml) 100+150
It is required in biotechnology, Molecular Biology applications in colleges, Universities, and Research Institutes.
It is meant for nucleic acid (DNA) characterization.
These are also called submarine electrophoresis unit/agrose gel/poly
The unit is jointless, moulded of transparent polycarbonate to avoid leakae.
It is fitted with 2 platinum electrodes and supploed with a transparent jointless safety lid which is also made of polycarbonate.
The unit is jointless mouldeed of trabsparent polycarbonate to avoid leakage.
These are research models of Tranilluminator. We have 3 model detailed as under.
Specifications.
Parameters
Model: TI-50
Model: TI-60
Model: TI-40
Item
U. V. Transilluminator smart look, very accurate, research work
U. V. Transilluminator smart look, very accurate� � research work accurate for research
Ultra thin U. V. Transilluminator very for small look Portable, very work.
Dual Intensity
302mm
302 and 365mm
302 mm
No. of Tubes
6
6
LED base
Wattage
8 Watts
8 Watts
LED base
Detection limit
0.01 ngm. of stained D.N.A.
0.01 ngm. of stained D.N.A.
0.01 ngm of stained DNA
Body
Alluminium Pressure die casted body furnished in Black Pouder coating.
Alluminium Pressure die casted body furnished in Black Pouder coating.
Alluminium Pressure die casted body furnished in Pink Pouder coating.