Fume hood is used to protect lab environment and operator during general chemical applications .It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Air Purifier is an air purification equipment, which is widely used in hospital, small clinic, laboratory, office, meeting room and house etc. it can protect your life and your health through filtering dust, germ and virus in the air. 1.Low noise. 2.Remote Control. 3. Adjustable air velocity. 4.QRJ-128:LCD Display; KJH-350:LED Display with touch button. 5. KJH-350:Thorough sterilizing with blue light UV lamp. 6. KJH-350:Eliminate formaldehyde efficiency: 96.2%;Eliminate PM2.5 efficiency:99.9%.
Air shower is a necessary passage for person entering clean room in order to minimized the amount of particulate contaminant, achieve workplace strict clean purificationstandards. Personnel move through the air shower while particulate contaminants are blew off by the clean high speed air. So the duct cannot be brought into clean area. Features: 1. Photoelectric sensor, automatic blowing. 2. Designed with circulation wind to ensure the cleanness of shower area under non-shower status. 3. Double doors with electric interlock. 4. Led display with adjustable blowing time (0-99 min). 5. Hepa filter, class 100 cleanness.
. 2 microplates, 80 sample rack, 92 dilution rack. ¡. 8 special reagent racks, 1 general reagent racks. ¢. Biological safety protection provides the high level of operator and environmental protection.
. 4 Pipetting probe, 1ul stepping (1000ul volumes). Total 25 racks, arbitrary rack can be defined as sample or reagent on the software. 4 units 96 well microplates (pipetting,incubator,reading).
.4 microplates,2 pipetting probes ¡. 192 sample positions , 96 dilution positions,23 reagent positions, 16 common reagent positions,48 QC positions. All sample & reagent positions can be editable.
It is used for the repaid sterilization of small instruments in stomatology, ophthalmology, e.N.T. Department, gynecology, operating room, etc. 1. It only takes 6-7 minutes for the shortest sterilization cycle which can extend service life of the instrument 2. Three shortcut keys for sterilization programs, the sterilization temperature and time can be set freely 3. Alarm for unqualified water and water shortage, the autoclave will stop working when there is a low temperature and low pressure 4. Small dimension, light weight, easy to operate, the cassette can be also used for instrument transfer and temporary storage
Application: It is applicable for the sterilization of unpacked solid instrument in department of stomatology, ophthalmology, operation room and CSSD. Features: 1. Automatic sterilization process 2. Drying function 3. Over-temperature, over-pressure protection device. 4. Interlock function. 5. Safety valve for over pressure protection. 6. Water level sensor. The power will be cut-off automatically in case of low water level. 7. 304 stainless steel material chamber.
Application: It is applicable for the sterilization of unpacked solid instrument in department of stomatology, ophthalmology, operation room and CSSD. Features: 1. Sterilizing programs for fabric, instrument, rubber and liquid. 2. Equipped with printer to print date, time and process parameters. 3. Build-in efficient steam generator, microcomputer temperature control. 4. Perfect four-level authority management system to avoid mis-operation. 5. The positive pressure air-exhaust system to exhaust the cold air from chamber. 6. Post-dying function makes the residual humidity of sterilized articles less than 3%. 7. Touch screen display of temperature, pressure, time, running status and failure warning. 8. Over-heat auto protection device, dual door safety lock device, over-pressure relief valve, short-circuit protection and over-pressure protection.
. 90 Sample positions. 90 Reagent positions. . 120 Reaction cuvettes. 550 Tests / Hour.
1. Main body: it adopts double layer structure. The chamber corner adopts circular arc transition, with no cleaning dead corner and anti-corrode. 2. Sealing door: double motor-driven door, compressed air technology. 304 stainless steel door, safety interlock, double door interlock. 3. Sterilizer control system: Siemens plc: with advanced control function, large storage and fault free operation time up to 50000 hours Micro-computer touch screen: with multi-function and three levels password protection. 4. Printer: it achieves real-time output by micro needle printer, could output the â??pressure, temperature, time, f0 value and other parameters and curves conveniently. 5. Temperature, pressure transmitter setting: Dual core temperature transmitter, work on system temperature and sterilization recording. Pressure transmitter: jacket and chamber sets separately. 6. Sterilizer pipeline system: Asco seat pneumatic valve Water ring type vacuum pump High function biology filter, teflon filter core
Autoclaves are equipment for sterilizing widely used in microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, dentistry, and prosthetics fabrication. They vary in size and function depending on the media to be sterilized. 1. Adopting European N standard, with thermal vacuum and drying functions, it can be used for A-type hollow instruments and solid instruments. Thermodynamic vacuum guarantees elimination of cold air from the cavity and makes sure that reaches the optimal effect of sterilization. 2. Specially design for dental clinic field, it could sterilize 12 pieces hand piece at same time, simply and efficiently. 3. Microprocessor control, LED display and modularized panel for easy operation. 4. Automatic malfunction detection system makes easy maintaining.
Application range: There are 5 fixed programs and 4 diy programs according to Different sterilization objects such as dressings, equipment, Tools, rubber, liquid, culture medium, waste, etc. Technical features: 1. Complete process of filling water, dynamic pulse exhaust, heating, sterilizing, draining and drying runs automatically. 2. Led screen displays all steps of full process as well as error codes. 3. Sterilization programs for dressings, equipment, rubber, culture medium, waste, etc. 4. Adopting certain temperature ( exhaust method and dynamic pulse exhaust method to completely empty the cold air inside chamber for ensuring steam saturability. 5. Automatic selecting quick or low exhaust to avoid sterilization liquid overflowing. 6. Inner stainless steel water tank for water and steam to circulate inside. Steam does not exhaust during sterilization, so as to keep the outside clean and dry. 7. Independent quick service window, easy for repairing and maintenance. 8. Water inlet filter to keep high water quality. 9. Hand wheel type of quick-open door structure, self-expandable sealing ring, easy operating and safe. 10. Optional printer for recording sterilization data.
Product introduction: BIOBASE Plasma sterilizer takes H2O2 assterilizing agent and from plasmatic state of H202 by electromagnetic field under low temperature. It combines both gaseous and plasmatic H2O2 to make sterilization for the items in chamber and decomposed the residual H2O2 after sterilization. It is widely used in CSSD or other medical institute for the steriliza- tion of electric wire and cable, optical glasses and glass lens, power equipment and batteries, endoscopes, catheter, nonmetallic and other wet or heat sensitive instruments.
Application: Hot air sterilizer is usedto sterilize small surgical instrument, glass, petri dishes etc. This device is suitable for medical and veterinary clinics, hospitals, pharmacies, health care centers, and laboratories.
Range of application: It's desk-top autoclave sterilizer which is designed for the hospital, clinic, lab, etc. It's mostly suitable for sterilizing of surgical, dental instruments, glassware, culture medium and biological dressing, food and goods, etc. Features: 1. Easy operation, safe and reliable. 2. Steam-water inner circulation system. 3.The sealing ring is made of silicon rubber. 4. Two safety valves keep double safety (for timing control type). 5. It has self-adjustment function (for timing control type) 6. It is well sealed and effectively prevents steam leakage. 7. Over temperature & over pressure auto-protection. 8. Electric heating or gas heating can be used (for dual fuel type). 9. The sterilizer is provided with a power switch, user can control the operation easily. 10. Immersion type electric heating pipe, thermal efficiency is high, stainless steel material tube is durable To use. 11. Double groove pressure gauge, could clearly indicate, convenient observation, reliable performance. 12. When at lower water level, or at the end of heat preservation time, have buzzer alarm, Timing control type will automatically stop heating (for timing control type).
Three protection: operator, sample and environment. Airflow system: 70% air recirculation, 30% air exhaust A2 cabinet is suitable for work with microbiological research in the absence of volatile or toxic chemicals and radionuclide. Advantage: 1. Motorized front window. 2. Time reserve function. 3. Hepa filter life and uv life indicator. 4. Automatic air speed adjustable with filter block. 5. Work area surrounded by negative pressure, it can ensure maximum safety in work area. 6. Audio and visual alarm (filter replacement, window over height, abnormal air flow velocity etc). 7. Most accessories are standard. No need to pay more, save your money. 8. Remote control. All functions can be realized with it, making the operation much easier and more convenient. 9. Foot switch. Adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement. 10. Interlock function: uv lamp and front window; uv lamp and blower, fluorescent lamp; blower and front window .
. 20 incubating positions. ¡. Membrane keyboard. ¢. Bulid-in thermal printer. £. Real-time graph display
Rotary evaporators come with a modular heating bath, vertical glassware, and digital temperature rotation control. The optimized bath volume allows fast heat-up times. The condenser unit has specially designed glass tubes that utilize surface extremely efficiently. We offer rotary evaporator with reasonable price, delivering reliable and reproducible process results, which is usually reserved for costly systems in the market.
Rotary evaporator is a device widely used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation. These machines are most often used to separate solvents of low boiling points, such as n hexane or ethyl acetate, from compounds which are solid at room temperature and pressure. Careful application also allows removal of a solvent from a sample containing a liquid compound, if there are minimal co-evaporation and a sufficient difference in boiling points at the chosen temperature and reduced pressure.