Please click here to check who's online and chat with them.

Find Verified Industrial Chemicals Suppliers, Manufacturers and Wholesalers

Sep-13-16
Supplier From Ha Noi, Viet Nam
Aug-28-18
Supplier From Mumbai, India
Jan-16-22
Supplier From Sto Domingo, Albay, Philippines
Jul-19-24
Supplier From United Kingdom
Mar-19-19
Supplier From Incheon, Incheon, South Korea (Republic Of Korea)
31828 Industrial Chemicals Suppliers
Short on time? Let Industrial Chemicals sellers contact you.
Oct-15-24
Supplier From Hai Phong, Viet Nam
Dec-08-21
Supplier From Hanoi, Viet Nam
Oct-02-21
Supplier From Philippines
Jun-15-21
Supplier From Surabaya, East Java, Indonesia
Apr-12-21
Supplier From India
Feb-01-21
Supplier From Sri Lanka
Jan-02-20
Supplier From Kenya
Oct-11-19
Supplier From Islamabad, Pakistan
Nov-18-18
Supplier From Davao, Philippines
Oct-23-18
Supplier From Ho Chi Minh, Viet Nam
Aug-07-19
Supplier From Tianjin, China
Apr-10-19
Supplier From Islamabad, Pakistan
Aug-27-22
Supplier From Japan
Nov-15-19
Supplier From Foshan, Guangdong, China
Dec-15-21

Zinc Oxide Arrester Tester

$770.00 - $15.4k
MOQ: Not Specified
 
Product description

The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester MOA leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests.



Zinc oxide arrester tester Technical Indexes

Range of reference voltage input peak 10V-200V

Measurement range of full leakage current peak 100uA 10mA

Measurement range of resistive current peak 100uA 10mA

Measurement range of capacitive current peak 100uA 10mA

Measurement range of angle 0-90

Power consumption 4W

System measurement accuracy reading 5 5 words not more than 2m for harmonic current

AC power supply AC 220V 10 50Hz 1



Precautions

When measure the reference voltage from PT or the measuring end of the testing transformer, carefully check wiring to avoid the PT secondary or test voltage short circuit.

Be careful not to wrongly connect the current and voltage sampling lines in the connecting process.

In the laboratory experiment, the high voltage power supply cannot use the series excitation testing transformer.
31828 Industrial Chemicals Suppliers
Short on time? Let Industrial Chemicals sellers contact you.