Function & Feature
1. QPCX electrical transducer converts ac current and voltage signals into a load independent dc signal
proportional to active power (watt), reactive power (var) and power factor (PF). With an extra output
channel for customized. Total four channel output for electrical data sampling use.
2. The current and voltage signals are passed into the circuit via precision instrument transformers to
provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current
and voltage signals is mathematically multiplied together to produce a product signal proportional to
true power and independent of wave shape and phase angle.
3. This combination transducers with RS485 communication port, it can be connected to a variety of
measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers,
digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature
1. QPK transducer converts ac current and voltage signals into a load independent dc signal proportional
to reactive power (vars). This signal is capable of driving a number of independent instruments.
2. The current and voltage signals are passed into the circuit via precision instrument transformers to
provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current
and voltage signals is mathematically multiplied together to produce a product signal proportional to
true power and independent of wave shape and phase angle.
3. These var transducers to be connected to a variety of measuring and control devices and systems,
such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Function & Feature
1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise
measurement.
2. Voltage transducer converts an ac voltage input into a load independent output signal.
3. Excellent temperature characteristic and good working stability.
4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence
the transducer can be used with distorted waveforms.
5. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5,
clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test
voltage.
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
506 Inductors Transducers Suppliers
Short on time? Let Inductors Transducers sellers contact you.
Function & Feature
1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Function & Feature
1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input
signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Specifications
Inputs:
System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V
Absorbed power 0.1VA
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Respones time
Function & Feature
1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise
measurement.
2. Current transducer converts an ac current input into a load independent output signal.
3. Excellent temperature characteristic and good working stability.
4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence
the transducer can be used with distorted waveforms.
5. The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5,
clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test
voltage.
Specifications
Inputs:
System current 1A, 5A, 10A, 30A
Absorbed power 0.3VA
Frequency range 50Hz, 60Hz
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Ripple
Function & Feature
1. QPCX electrical transducer converts ac current and voltage signals into a load independent dc signal
proportional to active power (watt), reactive power (var) and power factor (PF). With an extra output
channel for customized. Total four channel output for electrical data sampling use.
2. The current and voltage signals are passed into the circuit via precision instrument transformers to
provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current
and voltage signals is mathematically multiplied together to produce a product signal proportional to
true power and independent of wave shape and phase angle.
3. This combination transducers with RS485 communication port, it can be connected to a variety of
measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers,
digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Specifications
Inputs:
Nominal input 1 or 5 Amp C.T. connected
110V, 230V, 240V, 400V, 415V ac +/-20%
Power consumption
Function & Feature
1. QPK transducer converts ac current and voltage signals into a load independent dc signal proportional
to reactive power (vars). This signal is capable of driving a number of independent instruments.
2. The current and voltage signals are passed into the circuit via precision instrument transformers to
provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current
and voltage signals is mathematically multiplied together to produce a product signal proportional to
true power and independent of wave shape and phase angle.
3. These var transducers to be connected to a variety of measuring and control devices and systems,
such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Specifications
Inputs:
Nominal input 1 or 5 Amp C.T. connected
110V, 230V, 240V, 400V, 415V ac +/-20%
Power consumption
Function & Feature
1. QPPX electrical transducer measures a wide range of electrical parameters and generates analog or
digital output signals suitable for interfacing with instrumentation and control systems. Total four
channel output, with panel key or PC control programmable, user can free to set 4 different data from
max 26 electrical parameter for sampling and analog signal output.
2. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can
monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA
software. Any of the measured parameters can be read out via the optional RS485-Modbus
connection.
3. QPPX also can be used to configure the connection to the measured circuit for single-phase,
three-phase three-wire, three-phase four-wire, balanced or unbalanced load. Can be connected to a
variety of measuring and control devices and systems, such as analogue meters, PLC, computers,
data loggers, digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Specifications
Inputs:
Nominal input 1 or 5 Amp C.T. connected
110V, 230V, 240V, 400V, 415V ac +/-20%
Power consumption
Function & Feature
1. Isolate the DC voltage input signal from the DC Output signal, which is directly proportional to the input
signal.
2. These isolators can be used to prevent earth loops, which occur when a measuring source
3. Excellent temperature characteristic and good working stability.
4. It have an advantage over loop powered units, in that if for any reason the output lead should become
disconnected, the input will not be saturated.
5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Specifications
Inputs:
System input 0~5V, 0~30V, 0~60V, 0~300V, 0~400V
Absorbed power 0.1VA
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Respones time
Function & Feature
1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise
measurement.
2. Voltage transducer converts an ac voltage input into a load independent output signal.
3. Excellent temperature characteristic and good working stability.
4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence
the transducer can be used with distorted waveforms.
5. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5,
clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test
voltage.
Specifications
Inputs:
System voltages 100V,220V, 380V, 450V
Absorbed power 0.5VA
Frequency range 50Hz, 60Hz
Output:
Standard nominal outputs 4~20mA, 0-5V,
(others on request) 0-20mA,
5-10V
0-10V
Ripple
Function & Feature
1. QPW transducer converts ac current and voltage signals into a load independent dc signal
proportional to active power (watt). This signal is capable of driving a number of independent
instruments.
2. The current and voltage signals are passed into the circuit via precision instrument transformers to
provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current
and voltage signals is mathematically multiplied together to produce a product signal proportional to
true power and independent of wave shape and phase angle.
3. These watt transducers to be connected to a variety of measuring and control devices and systems,
such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Specifications
Inputs:
Nominal input 1 or 5 Amp C.T. connected
110V, 230V, 240V, 400V, 415V ac +/-20%
Power consumption
Function & Feature
1. QPWK transducer converts ac current and voltage signals into a load independent dc signal
proportional to active power (watt) and reactive power (var). Two output signals combination in one
transducer.
2. The current and voltage signals are passed into the circuit via precision instrument transformers to
provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current
and voltage signals is mathematically multiplied together to produce a product signal proportional to
true power and independent of wave shape and phase angle.
3. This var transducers to be connected to a variety of measuring and control devices and systems, such
as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems.
4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Specifications
Inputs:
Nominal input 1 or 5 Amp C.T. connected
110V, 230V, 240V, 400V, 415V ac +/-20%
Power consumption
We are a leading manufacturer of high-performance sensors engineered to deliver accuracy, reliability, and innovation across industries. With 30 years of expertise in advanced sensing technology, we design and produce cutting-edge solutions that empower automation, IoT, and smart systems worldwide.
Industry-specific attributes
CAS No. 7440-22-4
Purity 71.0�±2.0%
Other attributes
Place of Origin Guangdong, China
Other Names CHIP INDUCTOR SILVER PASTE
Grade Standard Industrial Grade, Electron Grade
Application CHIP INDUCTOR
Brand Name LONGXIN
Model Number LX-DG1002L
Solid content(%) 71.0±2.0
Viscosity (dPa.s) 600-700
Fineness(m) 10.0
Pulling force(KG) 10
AIT1000-SG has a high gain and measurement accuracy in the full bandwidth range, due totheapplicationof the multi-point zero-flux technology system and high-frequency ripple sensing channel ontopof currentlyexisting DC sensor technology. The multi-point zero-flux technology system secures the high accuracy by utilizing thetechnologycombination of exciting magnetic flux closed-loop control, self-excited magnetic fluxgateandmulti-closed-loop control that realizes the closed-loop control between excitation magnetic fluxandAC/DCmagnetic flux generated by primary current, while the high-frequency ripple sensing channel allowsthesensor to have the high performance over the full bandwidth range.
BMS500 fluxgate transducer is made of an excitation magnetic ring and a control circuit. Under normal
conditions, the control circuit generates a fixed excitation current frequency to alternately place the magnetic
core at the maximum saturation point. When the measured current flows, the primary current is measured by
detecting the symmetry of the saturation point.
The BMS series is suitable for battery monitoring systems that require high accuracy and low offset.
It can realize the isolation measurement between the primary current (high voltage) and the secondary
current (12V system).
PHEV and EV system may use different technologies of batteries. One very important parameter that mayinfluence the stability of the SOC is the temperature. The battery temperature affects vehicle performance, reliability, safety and lift-cycle cost. The BMS500 series is qualified between -40 to 85 but the transducer shows a better accuracyinarestricted temperature range in order to deliver a very accuracy current measurement.
506 Inductors Transducers Suppliers