LC 105 is an ideal one product boiler internal treatment. It can control not only calcium carbonate & calcium phosphate deposits but also calcium sulfate and barium sulfate. Highly concentrated alkaline product. Eliminates excessive precipitation of solids and reduces sludge accumulation. Application For use with make-up water with hardness below 150 ppm and effectively disperses iron oxides as well as calcium phosphate and clay. Injected directly into the boiler by means of a proportioning pump. It is environmentally safe, non-hazardous and non-corrosive. Dosage Initial : 2 quarts per 100 gallons or 1 : 200 Maintenance: 1 quart for every 100 gallons of make-up water or 1 : 400 Maintain 15-25 ppm (mg/l) of orthophosphate in the boiler waters with pH between 11.0 – 12.0. Maintain Conductivity below 5000 µmho/cm. Consult LifeChem Technical Services when Hardness is low or high. Handling & Precaution LC 105 is an alkaline product and should be handled with care to prevent personal injury. Wear protective clothing and eye protection. In case of contact with skin, immediately flush with water. In case of contact with eye, flush with water for 15 minutes and obtain immediate medical attention. Triple rinse used cans before reuse or disposal. Packaging Available in pail of 20 lt. Can also be custom packaged.
LC 255 is a versatile and highly effective rust preventative for use on unpainted metals during outdoor storage or overseas shipping. LC 255 protects metal with heavy waxy film. It does not require any surface cleaning or preparation and covers the metal like a paint, but easily removable. LC 255 provides protection for storage of metal, equipment, tools, tanks, structures, machinery, castings, fittings, valves, doors, frames, fixtures, jigs, etc. Application: LC 255 can be applied by spraying, brushing or dipping. It is recommended to apply by dipping in a tank with water draining facilities which ensures maximum coverage, penetration and cost effectiveness. LC 255 absorbs water and moisture while lubricating plated surfaces and bare metals such as steel, iron, alumunium, copper, brass and lead. Handling & Precaution: Avoid contact with eyes and skin. In the case of contact with eyes, wash immediately with plenty of water. Seek medical advice. If ingested, do not induce vomiting, seek medical attention. Packaging: Available in pail of 20 lt.. Can also be custom packaged.
LC 104 is an ideal single product boiler internal treatment, specially formulated by blending sludge conditioner & oxygen scavenger for dual function in packaged boiler systems. It can control not only calcium carbonate & calcium phosphate deposits but also calcium sulfate and barium sulfate. Highly concentrated alkaline product. Eliminates excessive precipitation of solids and reduces sludge accumulation. The oxygen scavenger prevents pitting corrosion in the boiler system. It is environmentally safe, non-hazardous and non-corrosive. Application Used in packaged boilers below 5 Tons/Hr. For use with make-up water hardness below 150 ppm and effectively disperses iron oxides as well as calcium phosphate and clay. Injected directly into the boiler by means of a proportioning pump. Dosage Initial : 2 quarts per 100 gallons or 1 : 200 ratio Maintenance: 1 quart for every 100 gallons of make-up water or 1 : 400 ratio Maintain 15-25 ppm (mg/l) of orthophosphate in the boiler waters with pH between 11.0 – 12.0. Maintain Conductivity below 3000 µmho/cm. Consult LifeChem Technical Services when Hardness is low or high. Handling & Precaution LC 104 is an alkaline product and should be handled with care to prevent personal injury. Wear protective clothing and eye protection. In case of contact with skin, immediately flush with water. In case of contact with eye, flush with water for 15 minutes and obtain immediate medical attention. Triple rinse used cans before reuse or disposal. Refer to MSDS for detailed information. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lc 120 is a product which effectively prevents scale and Corrosion in cooling towers having very soft waters which Are more corrosive, have a rysnar index over 7 and Calcium 25 – 75 ppm in the make-up water. It is an Excellent dispersant for calcium phosphate, iron oxides And clay. This product is used where heavy metals and Zinc is not allowed in effluent waters. Lc 120 is a Hydroxy-phosphonoacetic acid with polymers and copolymers To control scaling. It also has inorganic Phosphate and sodium tolytriazole to prevent corrosion And pitting of all metal surfaces. Application Injected directly into the circulating pipe upstream from the condenser. Cycles of concentration will vary from 5 – 20 as a probable upper limit. For Higher limits consult our laboratory. Dosage Feed lc 120 from a chemical mix tank or directly from the drum by means Of a proportioning pump at the rate of 0.5 pound / 1, 000 gallons of make-up Water. Adjust the dosage to maintain 5 – 10 ppm of orthophosphate in the Circulating water. A ph of 8.0 – 8.5 must be maintained. Handling & precaution Protective clothing and eye protection should be worn. In case of skin Contact, immediately flush thoroughly with plenty of clean water. In case of Eye contact, flush with copious of amounts of water for 15 minutes and Obtain immediate medical attention. Packaging Available in pail of 20 lt.. Can also be custom packaged .
Iron nails, heat press sublimation.
Copper Ore