Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Anand   New Delhi   Mumbai  
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31FF012SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF012SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9125 903
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-19-21
 
GBCDG31FF013SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF013SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 902
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31FF013SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF013SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 902
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31FF014SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF014SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31FF014SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF014SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ 013
Wiring Diagram MFDZ801-103-1
782 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-19-21
 
GBCDG31FF015SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay model No CDG31FF015SBCH
Relay type CDG 31 Special
Case size 3D V 20T
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Current setting - E/F 0.2 to 0.8 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
BURDE / D.M.T 3 VA / 1.3 Secs
C.T.Secondary 1 amps
Frequency 50 Hz
Flag Yes
Mounting Flush
Name Plate RFG9125 902
Outline drawing MFJ 013
Wiring diagram MFDZ 801.130-1
VERIFIED
Jun-19-21
 
GBCDG31FF021SBCH
IDMT 2 O/C & 1 E/F RELAYS SPL 150 HZ.
Technical specification
Relay model No CDG31FF021SBCH
Relay type CDG 31 Special
Case size 3D V 20T
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Current setting - E/F 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
BURDE / D.M.T 3 VA / 3 Secs
C.T.Secondary 5 amps
Frequency 150 Hz
Flag Yes
Mounting Flush
Note to test:Relay to test
150 Hz. refer test inst.
Name Plate RFG9126 903
Outline drawing MFJ 013
Wiring diagram MFDZ 801.101-1
VERIFIED
Jun-19-21
 
Alstom Gbcdg31ff8101lch
3idmt,2 O/c & 1 E/f ,3va 3 Secs Dmt 50hz
Technical Specification
Model No. Cdg31ff8101lch
Case Size : 3d Ver.
Application : 2 O/c & 1 E/f
Ct Secondary : 5 Amps
Current Setting O/c : 2.5 to 10 Amps
Current Setting E/f : 1 to 4 Amps
Contacts : 2m 2b H/r.
Output Contacts : 2m 2b H/r.
Taps : Std.
Burden / Operating Time : 3 Va 3 Secs.
Frequency : 50 Hz.
Name Plate : Rfg9126 904
O/l & Arrangement : Mfj 013
Wiring Diagram : Mfdz 801.95 - 1
VERIFIED
Jun-19-21
 
Alstom Gbcdg31ff8111lch
3idmt,2o/c & 1e/f,3va 1.3secs, Dmt 50hz
Technical Specification
Relay Model No Cdg31ff8111lch
Type Cdg31
Application 2 O/c + 1 E/f
Burden / D.m.t. 3va / 1.3 Sec.
C.t. Secondary 5 Amp C.t.
Case Size 3d Vert.
Contacts (S/r or H/r) 2 N/o 2 N/c H/r
E/f Setting 1 - 4 Amps.
Flag Yes
Frequency 50 Hz
Mounting Flush
O/c Setting 2.5 - 10 Amps.
Name Plate Rfg9125-904
Outline Drawing Mfj013
Wiring Diagram Mfdz801.95-1
VERIFIED
Jun-19-21

Alstom Relay

$1.50K
MOQ: Not Specified
 
Alstom Gbcdg61eg001zmch
Obs.replaced by Gbcdg61eg101zmch
Obs Model .replaced by Model List Gbcdg61eg101zmch
VERIFIED
Jun-19-21
 
ALSTOM GBCDG61EG003SXCH
IDMT THREE O/C RELAY WITH HIGH-SET
Technical Specification
Relay model no CDG61EG003SXCH
Relay type CDG 61
Case size 3D HOR.30T
Application O/C
Current setting - O/C 2.5 to 10 amps
Contacts 3Meter S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Taps Std
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
High set - O/C Setting 20 to 80 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 774
Outline drawing MFJ 014
Wiring Diagram MADZ 821.27-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG61EG006SXCH
IDMT THREE O/C RELAY WITH HIGH-SET
Technical specification
Relay model no CDG61EG006SXCH
Relay type CDG 61
Case size 3D HOR.30T
Application O/C
Current setting - O/C 0.5 to 2 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Taps Std
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
High set - O/C Setting 4 to 16 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 771
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
 
GBCDG61EG011SGCH
IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI
Technical specification
Relay model no CDG61EG011SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Taps / Frequency STD / 50 Hz
Burden 3 VA
Operating time 3 secs
Flag Yes
Current setting - E/F 1 to 4 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 10 to 40 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 904
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG61EG018SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG018SGCH
Relay type CDG 61
Case size 3D H 30T
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Tap Std
Burden / D.M.T 3 VA / 3 Secs
Current setting - E/F 0.2 to 0.8 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 2 to 8 amps
High set/High set contact CAG 13 / 2 N/O S/R
Name plate RFG9126 902
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
 
ALSTOM GBCDG61EG020SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG020SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.1 to 0.4 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 1 to 4 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 901
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
May-20-14
 
Single-use visual impact indicator mounted directly to product packaging. Activates when exposed to impact beyond desired threshold and turns bright red to indicate mishandling.
Single use, go/no go devices that determine if fragile products have been dropped during transit or in storage. Field-armable, tamper-proof devices that turn bright red when an impact beyond a specific threshold has occurred. Each unit has a unique identifier to support traceability.
VERIFIED
May-20-14
 
To facilitate the clients, further we are offer authentic range of impact & environmental recorders that is used for recording varied environment conditions during transportation, storage as well operation. These recorders are assembled and incorporated with latest gps / gprs tracking module required to record any kind of impact and generate reports so as to decrease the rate of products damaging. The various environmental factors like humidity, temperature changes, till and atmospheric pressure can be recorded in this devise and can be rectified to reduce the damaging of the products. They are capable of recording shock, vibration or any environment related impact conditions and can exactly record the time duration of the mishandling. These devices are incorporated with advance triaxial piezoelectric accelerometer technology is used for recording the exact amplitude and direction of impact that enables to set certain control measures to prevent the products from damaging further.
VERIFIED
May-20-14
 
Shockwatch tip and tilt sensors continually monitor and/or report the conditions products are exposed to during transit, storage, and operation.
Attach one of the tiltwatch family of products directly to a package or container’s exterior surface, to monitor the ‘care in handling’.
Tiltwatch xtr tip indicator monitors goods that must remain upright to ensure intact delivery. Tiltwatch xtr is a single-use tip indicator that does not activate until it is at an 80o angle +/-5% from vertical.
Tiltwatch plus attached to package’s exterior surface, ‘peel and stick’ pressure sensitive label, is actually three separate registers in a single tilt indicator unit, providing inexpensive 360° tilt monitoring for the entire duration of shipping transit and an unalterable record of damaging excesses.
VERIFIED
May-20-14
 
The skid-mate is an air dampened cushioning device that provides a fast, cost effectiveand durable customized solution to protect sensitive products from shock and vibration. Theskid-mate can be easily mounted on a crate or pallet base creating an air-ride cushion in placeof hardwood skid runners eliminating the need for expensive air-ride trucks.Each color coded skid-mate corresponds to a specific load range and allows users to calculatetheir requirements simply and easily to avoid potential laboratory testing and use of expensivepackaging materials.

Reduce packaging design & assembly time and cost• eliminate costly damage from handling hazards during shipment• reduce costs associated with shock and vibration damage
Jun-03-22
 
> 2 x 2-wire, 4~20 mA or 0~10V DC outputs with RTD resistance output option
> Any or both outputs can be assigned to RH or T or Dew point or specific derived physical quantity
> RH & T range selection, parameter configuration and calibration with
> USB to serial converter (DCC501)
> Handheld configurator (HHC202)
> Inbuilt LCD and 3 keys
>. Health / status (Heartbeat) LED

> Calculated physical quantities
-Dew point
-Absolute humidity
-Heat index
-Enthalpy
-Air density

> Isolated RS485 / MODBUS RTU or BACnet MS/TP
> Replaceable RH+T sensor
> Convenient installation with 2-part housing with fixed back and removable electronics
> Stylish housing with vents for air flow across sensor for better accuracy
782 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.