ALSTOM GBCDG31FF012SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF012SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. NAME PLATE - RFG9125 903 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-103-1
GBCDG31FF013SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF013SB(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.2 - 0.8 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 902 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-101-1
ALSTOM GBCDG31FF013SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF013SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.2 - 0.8 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 902 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-103-1
ALSTOM GBCDG31FF014SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF014SBCH RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.1 - 0.4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 901 Outline Diagram MFJ013 Wiring Diagram MFDZ801-101-1
ALSTOM GBCDG31FF014SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF014SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.1 - 0.4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 901 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-103-1
GBCDG31FF015SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical specification Relay model No CDG31FF015SBCH Relay type CDG 31 Special Case size 3D V 20T Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Current setting - E/F 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std BURDE / D.M.T 3 VA / 1.3 Secs C.T.Secondary 1 amps Frequency 50 Hz Flag Yes Mounting Flush Name Plate RFG9125 902 Outline drawing MFJ 013 Wiring diagram MFDZ 801.130-1
GBCDG31FF021SBCH IDMT 2 O/C & 1 E/F RELAYS SPL 150 HZ. Technical specification Relay model No CDG31FF021SBCH Relay type CDG 31 Special Case size 3D V 20T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Current setting - E/F 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std BURDE / D.M.T 3 VA / 3 Secs C.T.Secondary 5 amps Frequency 150 Hz Flag Yes Mounting Flush Note to test:Relay to test 150 Hz. refer test inst. Name Plate RFG9126 903 Outline drawing MFJ 013 Wiring diagram MFDZ 801.101-1
Alstom Gbcdg31ff8101lch 3idmt,2 O/c & 1 E/f ,3va 3 Secs Dmt 50hz Technical Specification Model No. Cdg31ff8101lch Case Size : 3d Ver. Application : 2 O/c & 1 E/f Ct Secondary : 5 Amps Current Setting O/c : 2.5 to 10 Amps Current Setting E/f : 1 to 4 Amps Contacts : 2m 2b H/r. Output Contacts : 2m 2b H/r. Taps : Std. Burden / Operating Time : 3 Va 3 Secs. Frequency : 50 Hz. Name Plate : Rfg9126 904 O/l & Arrangement : Mfj 013 Wiring Diagram : Mfdz 801.95 - 1
Alstom Gbcdg31ff8111lch 3idmt,2o/c & 1e/f,3va 1.3secs, Dmt 50hz Technical Specification Relay Model No Cdg31ff8111lch Type Cdg31 Application 2 O/c + 1 E/f Burden / D.m.t. 3va / 1.3 Sec. C.t. Secondary 5 Amp C.t. Case Size 3d Vert. Contacts (S/r or H/r) 2 N/o 2 N/c H/r E/f Setting 1 - 4 Amps. Flag Yes Frequency 50 Hz Mounting Flush O/c Setting 2.5 - 10 Amps. Name Plate Rfg9125-904 Outline Drawing Mfj013 Wiring Diagram Mfdz801.95-1
Alstom Gbcdg61eg001zmch Obs.replaced by Gbcdg61eg101zmch Obs Model .replaced by Model List Gbcdg61eg101zmch
ALSTOM GBCDG61EG003SXCH IDMT THREE O/C RELAY WITH HIGH-SET Technical Specification Relay model no CDG61EG003SXCH Relay type CDG 61 Case size 3D HOR.30T Application O/C Current setting - O/C 2.5 to 10 amps Contacts 3Meter S/R Output contacts 2M S/R C.T.Secondary 5 amps Taps Std Frequency 50 Hz Burden 3 VA Operating time 3 secs Flag Yes High set - O/C Setting 20 to 80 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 774 Outline drawing MFJ 014 Wiring Diagram MADZ 821.27-1
ALSTOM GBCDG61EG006SXCH IDMT THREE O/C RELAY WITH HIGH-SET Technical specification Relay model no CDG61EG006SXCH Relay type CDG 61 Case size 3D HOR.30T Application O/C Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Taps Std Frequency 50 Hz Burden 3 VA Operating time 3 secs Flag Yes High set - O/C Setting 4 to 16 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 771 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG011SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no CDG61EG011SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Taps / Frequency STD / 50 Hz Burden 3 VA Operating time 3 secs Flag Yes Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG018SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG018SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Tap Std Burden / D.M.T 3 VA / 3 Secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set/High set contact CAG 13 / 2 N/O S/R Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Single-use visual impact indicator mounted directly to product packaging. Activates when exposed to impact beyond desired threshold and turns bright red to indicate mishandling. Single use, go/no go devices that determine if fragile products have been dropped during transit or in storage. Field-armable, tamper-proof devices that turn bright red when an impact beyond a specific threshold has occurred. Each unit has a unique identifier to support traceability.
To facilitate the clients, further we are offer authentic range of impact & environmental recorders that is used for recording varied environment conditions during transportation, storage as well operation. These recorders are assembled and incorporated with latest gps / gprs tracking module required to record any kind of impact and generate reports so as to decrease the rate of products damaging. The various environmental factors like humidity, temperature changes, till and atmospheric pressure can be recorded in this devise and can be rectified to reduce the damaging of the products. They are capable of recording shock, vibration or any environment related impact conditions and can exactly record the time duration of the mishandling. These devices are incorporated with advance triaxial piezoelectric accelerometer technology is used for recording the exact amplitude and direction of impact that enables to set certain control measures to prevent the products from damaging further.
Shockwatch tip and tilt sensors continually monitor and/or report the conditions products are exposed to during transit, storage, and operation. Attach one of the tiltwatch family of products directly to a package or container’s exterior surface, to monitor the ‘care in handling’. Tiltwatch xtr tip indicator monitors goods that must remain upright to ensure intact delivery. Tiltwatch xtr is a single-use tip indicator that does not activate until it is at an 80o angle +/-5% from vertical. Tiltwatch plus attached to package’s exterior surface, ‘peel and stick’ pressure sensitive label, is actually three separate registers in a single tilt indicator unit, providing inexpensive 360° tilt monitoring for the entire duration of shipping transit and an unalterable record of damaging excesses.
The skid-mate is an air dampened cushioning device that provides a fast, cost effectiveand durable customized solution to protect sensitive products from shock and vibration. Theskid-mate can be easily mounted on a crate or pallet base creating an air-ride cushion in placeof hardwood skid runners eliminating the need for expensive air-ride trucks.Each color coded skid-mate corresponds to a specific load range and allows users to calculatetheir requirements simply and easily to avoid potential laboratory testing and use of expensivepackaging materials. Reduce packaging design & assembly time and cost• eliminate costly damage from handling hazards during shipment• reduce costs associated with shock and vibration damage
> 2 x 2-wire, 4~20 mA or 0~10V DC outputs with RTD resistance output option > Any or both outputs can be assigned to RH or T or Dew point or specific derived physical quantity > RH & T range selection, parameter configuration and calibration with > USB to serial converter (DCC501) > Handheld configurator (HHC202) > Inbuilt LCD and 3 keys >. Health / status (Heartbeat) LED > Calculated physical quantities -Dew point -Absolute humidity -Heat index -Enthalpy -Air density > Isolated RS485 / MODBUS RTU or BACnet MS/TP > Replaceable RH+T sensor > Convenient installation with 2-part housing with fixed back and removable electronics > Stylish housing with vents for air flow across sensor for better accuracy