K2 EDTA Tubes
Specifications: Tube Size: 13-100 5.2mGs Membran Filtered EDTA K2 Sprayed
Description
EDTA stands for Ethylenedia minetetraacetic acid. EDTA functions by binding calcium in the blood and keeping the blood from clotting. It is used mostly i n Hematology studies: CBC, WBC Count, Hemoglobin, Hematocrit, Platelet Count, Reticulocyte count, and differential.
Minimum Order Quantity: 15000 Unit
Material: Plastic
Volume: 1ml, 10ml
Packaging Size: 100 Pcs
Cap Color: Red, Yellow, Lavender, Green, Black
Application: Clinical, Hospital, Laboratory
Quality Guarantee Period: 2 Years
Ethylene Oxide Sterilization: Without Ethylene Oxide Sterilization
Description
Features:
1. Sterilized
2. Sturdiness
3. Latex free
4. Crack resistant and transparent
5. Universal Color codes
6. Disposable, non toxic and pyrogen free
7. Protective plastic safety cap for non- spilling of blood
8. Special Medical grade rubber for stoppering
Infineon Corporation offers the entire range of vacuum blood collection tubes.
Blood Collection System is composed of evacuated tubes, single use blood collection needle and holder and Bio-Xs patented products Clear Spot Bandage, Together used for collection of blood in Labs / Hospitals.
Product Details:
Brand SD Biosensor
Specimen Whole blood
Specimen volume 1 mL
Storage temperature 2-25 C / 36-77 F
Cat. No 07TBF10C
Blood collection vacuum tube for diagnosis of latent tuberculosis infection
Intented Use
Blood collection vacuum tube which is used with STANDARD E TB-Feron ELISA for diagnosis of latent tuberculosis infection
Advantage
Specific detection of human IFN-I related to TB
Sensitive and specific IGRA test.
Product Details:
Brand SD Biosensor
Specimen Whole blood
Specimen volume 1 mL
Storage temperature 2-25 C / 36-77 F
Cat No 07TBF10C
Intented Use :
Blood collection vacuum tube which is used with STANDARD E TB-Feron ELISA for diagnosis of latent tuberculosis infection
Advantage:
Specific detection of human IFN-I³ related to TB
Sensitive and specific IGRA test
Vacuum Blood Collection Tube introduced by us promises to live up the expectations of the buyers. It is manufactured completely in clean room environment by using the best of the quality materials and assembled on a 100% Automatic assembly Line. We believe in quality and the same has been inculcated in our products.
We produce the tubes in two volumes 13 75 mm and 13 100 mm.
Variants :
K2 EDTA (2 ml - 6 ml)
K3 EDTA (2 ml - 6 ml)
Clot Activator (2 ml - 6 ml)
Sodium Heparin (2 ml - 6 ml)
Lithium Heparin (2 ml - 6 ml)
Sodium Fluoride (2 ml - 6 ml)
Sodium Citrate (2 ml - 6 ml)
Gel with Clot Activator (3.5 ml - 5 ml)
We follow the colour codes of ISO 6710:2016 for the manufacturing process of the tube.
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
LYBCON Vacutainer GEL-SST Advance tubes
During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components.
For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted.
Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested.
As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage.
The main advantages of gel tubes versus non-gel tubes are:
Stable barrier between serum and clotted blood, therefore better analyse stability.
Better sample quality.
Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube.
No possibility of misidentification due to the use of secondary tubes.
CLOTTING TIMES
The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes.
CENTRIFUGING CONDITIONS
1600-2000g for 10 minutes
MIXING RECOMMENDATION
Serum Separation Tubes should be gently inverted 180 and back 6-8 times.
EFFECTS OF TEMPERATURE
LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C.
Serum Separation Tubes should be gently inverted 180 and back 6-8 times.
SODIUM CITRATE
Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible.
LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations:
0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1.
The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis.
LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary.
FILL LINE MARKING
The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level.
CENTRIFUGING CONDITIONS
For coagulation analysis different plasma specifications can be obtained from the citrated blood.
Platelet rich plasma:150-200g for 5 minutes at 18-25 C
Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C
Platelet free plasma: >3000g for 15-30 minutes at 18-25 C
MIXING RECOMMENDATION
Citrate tubes should be gently inverted 180 and back 3-4 times.
SPECIFICATION
Specimen: Plasma or Whole
Additive: Sodium citrate 3.2% or 3.8% (9NC)
Cap color: Blue
Tube Size: 13x75mm
Draw Volume: 1.8mL, 2.7mL
Max. draw volume Tolerance: ±10%
84 Medical Tubes Suppliers
Short on time? Let Medical Tubes sellers contact you.