Indications: Complex intra-articular and extra-articular olecranon fractures. Pseudoarthrosis of the proximal ulna. Simple olecranon fractures. Repair of the olecranon after osteotomies in distal humerus surgery. Plate Features: Angular stable fixation of fragments regardless of bone quality. Minimised risk of primary and secondary loss of reduction, even under high dynamic loading. Reduced impairment of periosteal blood supply due to the limited plate contact.
Plate Features: Proximal Tibia Safety Lock Plate 3.5mm is used for Non-unions, Malunions, and fractures of Proximal Tibia, including Simple, Comminuted, Lateral wedge, Depression, Medial wedge, Bicondylar, Combination of Lateral wedge and depression and fractures associated with shaft. These plates can be anatomically contoured to match Proximal Lateral Tibia. These plates are designed for both right or left Tibia and are available in a variety of lengths. The head and three Proximal holes allow only 3.5 mm Safety Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws.
Clavicle Hook Safety Lock Plate 3.5 is indicated for Extra-articular and Intra-articular fractures of Lateral Clavicle . Anatomically precontoured: The plate facilitates optimal implant placement and surgery to provide an improved outcome. Rounded shaft profile minimizes the risk of soft tissue irritation between the plate and surrounding soft tissue. Undercuts in shaft reduce impairment of blood supply. The plates are designed for both Right and Left Clavicle bones and are available in a varying lengths and Hook depths. All holes of plate accept 3.5 mm cortex, 3.5mm safety lock and 4.0 mm cancellous screws.
Locking Proximal Humerus Plate is used for complex and unstable fractures. Indications Proximal Humerus Multifragmentary (dislocated) fractures requiring open reduction Unstable subcapital fractures Subcapital pseudarthrosis Osteotomies Suture holes The fixation of additional wireloops or sutures attached to the tubercles (in 3- or 4-fragment fractures) neutralises the muscle tension and helps to maintain reduction. The head of plate allows only 3.5 mm Safety Lock Screws and shaft of the plate allows both 3.5 mm Safety Lock and Cortical screws.
Used for the fractures of the clavicle shaft. Plate Features: Anatomically pre-shaped, twisted design. Due to Lateral superior placement, there is less need to detach muscles than with anterior placement. Undercuts reduce impairment of blood supply. Also used in osteoporotic bone and in multi fragment fractures. Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
Mini Cortex Screws Dia : 1.5mm Total Length : 6mm to 12mm (with 1mm diff.) : 14mm to 20mm (with 2mm diff.) Core Dia : 1.0mm Drill Bit : 1.1mm Tap : 1.5mm
Contents 4.5 mm Cortical Screws 8 Screws each of 14, 16, 18, 20, 22, 24, 26 & 28mm 64 nos. 16 Screws 30mm 16 nos 12 Screws each of 32, 34, 36, 38, 40 & 44mm 72 nos 6 Screws each of 42, 46, 48, 52 & 56mm 30 nos 5 Screws 60mm 5 nos 4 Screws each of 64 & 68mm 8 nos.
Mini Fragment Set Contents Instrument for 2.7 mm Screws ST003.01 Drill Bit 2mm 2 nos. ST203.03 Tap 2.7mm 2 nos. ST303.00 Tap Handle 1 no ST503.02 Drill Sleeve : 2mm 1 nos ST603.02 Tap Sleeve : 2.7mm 1 no ST113.01 Mini Neutral & Load Drill Guide 1 no ST403.02 Screw Driver with Sleeve 1 no ST013.01 Mini Depth Gauge 1 no ST013.04 Self Retaining Retractor 1 no
ST810.00 Large Fragment Set Contents ST992.05 : Drill Bits - 3.2mm : 2 nos. ST992.09 : Drill Bits - 4.5mm : 2 nos. ST903.03 : Counter Sink : 1 no ST203.07 : Bone Tap : 4.5mm : 2 nos ST103.09 : Bone Tap : 6.5mm : 1 no ST503.03 : Drill Sleeve 3.2mm / Tap Sleeve 4.5mm : 1 no ST403.04 : Large Hexagonal screw Driver : 1 no ST013.03 : Large Depth Gauge : 1 no ST113.03 : Neutral & load Drill Guide : 1 no ST303.00 : Tap Handle : 1 no
These plates deal with fractures and malunions of the clavicle shaft Plate Features: Anatomically pre-shaped, twisted design. Due to Lateral superior placement, there is lesser need to detach muscles than with anterior placement. Undercuts reduce impairment of blood supply. Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
Contents Instruments ST992.04 Drill Bit (S.S.) : 2.5mm 2 nos. ST003.02 Drill Bit (S.S. Quick Coupling End) : 2.5mm 1 nos. ST992.07 Drill Bit (S.S.) 3.5mm 1 no ST903.02 Counter Sink 1 nos ST203.04 Cortical Tap : 3.5mm 2 no ST203.05 Cancellous Tap : 3.5mm 2 no ST203.06 Cancellous Tap : 4mm 1 no
Contents ST853.08 : Wire Holding Forceps : 2 nos. ST853.09 : Wire Bending Forceps : 1 nos. ST853.07 : Wire Cutter Cum Plier 6 : 1 nos. ST853.05 : Wire Passer : small : 1 nos. Wire Passer : medium : 1 nos. Wire Passer : large : 1 nos. ST853.06 : Wire Tightner : 1 nos. ST853.01 : Bone Awl : 3 nos. ST853.04 : T. Handle : 1 nos.
Contents ST510.01 : Half Rings : 100mm : 6 nos. ST510.02 : Half Rings : 120mm : 8 nos. ST510.03-04 : Half Rings : 140 & 160mm (8 each) : 16 nos. ST510.05 : Half Rings : 180mm : 4 nos. ST510.06 K : Wire Clamps : 20 nos. ST510.07 : Ring Connecting Bolts : 10 nos. ST510.08 : Threaded Rods : 100, 150mm (8 each) : 16 nos.
Indications: The 3.5 mm LCP Extra-articular Distal Humerus Plates are indicated for fractures of the distal humerus. Plate features Left and right plates are anatomically contoured to match the posterolateral distal humerus. Two most distal holes are angled toward the capitulum and trochlea. Plate head tapered to minimize soft tissue irritation. A limited-contact plate design reduces plate-to-bone contact and helps to preserve the periosteal blood supply. Anatomic reduction: Fracture reduction and fixation to restore anatomical relationships. Stable fixation: Fracture fixation providing absolute or relative stability, as required by the patient, the injury, and the personality of the fracture. Early, active mobilization: Early and safe mobilization and rehabilitation of the injured part and the patient as a whole. Preservation of blood supply: Preservation of the blood supply to soft tissues and bone by gentle reduction techniques and careful handling.
The multidirectional and angular stable fixation system (TriLock technology) for the distal radius consists of implant plates, implant screws and the corresponding instruments. Plate thickness 1.3 mm, 1.6 mm, 2.0 mm and 2.2 mm HexaDrive in all screws, cortical and TriLock Consistent screw diameter: 1 twist drill, 1 screwdriver, locking or non-locking
Lag screws compress the fracture fragments together. There are two screw types by which to achieve this. In the Proximal Tibia most often cancellous bone screws are used due to the absence of real cortical bone.
The length of the shaft at the end of the campana cup can be cut As per the requirement and then inserted into the cylinder on the Thus only one tita-prostheses type partial vario Campana is needed for a particular partial ossicular Reconstruction. Four symmetrical holes on the disc enhance the surgeonâ??s view of The middle ear cavity. Offers best possible length selection. Campana shaped cup offers lowest risk of dislocation. Radial outer facing disk minimizes risk of tympanic membrane injury. Optimally roughened surface on outer face of disk and inside of cup ensure firm placement of prostheses. Mri compatible.
BIOMED HEALTHTECH PVT LTD (ISO 9001: 2000 certified) as India's reputed manufacturer and exporter of Orthopedic Implants & Instrumentation. It has been our constant endeavor to provide innovative solutions in the branch of Orthopedics and hence we are very pleased to offer our New Spinal Range Orthopedic implants’ demand is always increasing in developing country like ours. It does not need any kind of after sales service http://www.biomedorthopedics.com/ Complete Range of Orthopedic Implants & Instrumentations, such as: Interlocking Nails : Tibia / Femur / Recon / Supracondylar / PFN Plates : DHS , DCS , Locking , Distal , Proximal Trauma Range , Clavicle Screws Prosthesis : Austin Moore , Thomson Modular Bipolar Hip Joint & THR External Fixator , Rods & clamps Instruments Titanium Implants SPINAL RANGE : Monoaxial, Polyaxial Screws, Rods and Banana Cage for Spinal Surgeries Biomed is ISO and CE Certified and in existence since 1989 Biomed was pioneer in developing the Intra medullary Nailing Concept under the guidance of DR D. D. Tanna ( Head of All India Orthopedic Association ) Biomed conducted 55 Workshops and more all over India and Nigeria for training doctors in Interlocking Concepts All implants are made from 316 L Medical Grade Steel which is tested by the Metallurgy Department and Batch report is generated and thus batch numbers assigned to every implants Titanium range also available Biomed also customizes implants as per doctors specification. All Instrumentation Sets available with Elite Boxes for the same.
We are offering orthopedic operating table, Albee’s type orthopaedic attachment :- Ortho attachment allows the table to be used for the lower extremity procedures. Available at competitive prices our ortho attachment is purely made of stainless steel which resist corrosion. Features : This orthopedic extension device can be used with any operating table as it independently stands on the floor. Specially design for intra operative x-ray photos & image intensifier set use.In addition, a pelvic support plate is supported on top of the frame and is formed with an asymmetrical construction. The pelvic support plate includes a cutout area on a front corner thereof permitting additional access to the affected leg of a patient. Removable pelvic rest & x-ray translucent pelvic stemstirring instruments allows flexionraising of legs & stirringstring ball joints locked from foot end.Two traction devices on sliding spot with ball joint allowing flexions & rotations of foot with traction shoe with metallic sole. Padded orthopedic knee crutchesprovides support to the legs of the patient.Traction unit with supporter is so easily & collapsible that it requires a very small place.The plate may be flipped over to position the cutout area on the opposite side of the patient, depending on the location of the affected leg. Each piece is packed in plywood case.
Auxein medical is an orthopedic implants manufacturers & suppliers company approved by iso 9001:2008, iso 13485:2003 & ce