TEMPO make COD digester outer cabinet made of mild steel duly coated. Double wall construction with insulation for minimum heat losses increases the efficiency of the system. An aluminium block with holes (dimension 40 mm dia x 80 mm depth) is used to hold COD tubes. The aluminium block is heated to maintain the temperature up to 180�°C. Temperature range â?? Above ambient to 180�°C Resolution â?? 1�°C Supply â?? 230V, AC Features : Superior finish. Long-lasting Customized options Exceptional quality
This apparatus is an ideal instrument to check the sealing integrity of the blister packs, strip packs, sachet and pouch packs etc. It is also used for checking leaks from capped bottles, induction sealed containers, sealed or crimped containers etc. The leak test apparatus in a stainless steel body with phenomenal compactness. The instrument is equipped with a long-lasting vacuum pump, which gives a higher level of vacuum in the shortest possible time. Die pressed polycarbonate vacuum desiccator sustain vacuum for a long time. Application : Drugs manufacture (Blisters and small sachets containing tablets) Pain manufacturer Food manufacture (Sugar, spices, granulates) Mineral water bottle manufacturing Features : The very low noise level Polycarbonate vacuum desiccator sustains vacuum for a long time. Stainless steel 304 construction Built-in vacuum and isolating valve. Stable digital timer for auto stop Vacuum level up to 550 mm of Hg Audio alarm after completion of software.
TEMPO make soxhlet extraction heaters are designed to use in laboratories for solvent extraction under reflux. Typical applications are the determination of residual oil content in oil cake, assay of crude herbal drug sources etc. Max surface temp 400C Supply 230V, AC Construction : TEMPO make soxhlet extraction heaters is suitable to heat soxhlet flasks of 100-350 ml capacity. The heating element is attached to knitted fabric to provide flexible support to the bottom of the flask. Glass wool insulation fills the gap between the metal casing and the heater. In event of spillage, the solvent will either evaporate or escape through the draining hole below each element. The housing has two retort rods and a cross bar on which the extraction apparatus is fixed. The apparatus has an inbuild energy regulator which controls all the heaters. The heating elements have individual ON/OFF switch and pilot lamp to indicate working. Controlling System : Energy regulator and pilot lamp Heating System : The heating element is attached to knitted fabric to provide flexible support to the bottom of the flask. Glass wool insulation fills the gap between the metal casing & the heater.
TEMPO make a tray dryer are with the forced air circulation provided by means of motorized blower fitted on the oven for recirculation of air which ensures a homogeneous hot air mixture and an exact temperature profile. Temperature range 50C to 200C Temperature accuracy ±0.1C Supply 440V, three phase Controlling System : Microprocessors based auto tune PID temperature controller with & dual display of set value & process value for precise control of temperature with PT 100 sensor is used for temperature. Heating System : SS tubular heating elements used on the side walls to maintain a uniform temperature condition inside the chamber. Air Circulation : The motorized blower fitted on the top side of the chamber develop unique airflow system which ensures maximum temperature distribution inside the temperature. The unique airflow assures that there is a quick recovery after the doors are opened.
TEMPO make fume hood is a type of local ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapour's or dust. Air is drawn from lab space into the fume hood then dispersed via a pipe to the outside atmosphere. Basically, it protects the user from inhaling toxic gases. Application : Chemical lab Food manufacturer Drugs manufacturer company Paint manufacturing company Rubber industry Polymer industry Cement industry
Tempo make Laboratory Autoclave are suitable for Pharma & Biotech industries, Food research & Quality assurance labs, Agriculture research, Health care & Diagnostic labs, University, etc Technical Data : Temp. Range : 121 C to 125 C Pressure Range : 15 to 22 PSI Factory Set : 15 PSI at 121 C Supply : 230 Volt, AC, Single Phase, 50Hz
TEMPO make laboratory autoclave are suitable for pharma & biotech industries, food research & quality assurance labs, agriculture research, healthcare & diagnostic labs, university, etc. Temperature range 121 C to 125 C Pressure range 15 to 22 PSI Factory set 15 PSI at 121 C Supply 230V, AC Construction : Vertical double walled design has a single chamber for steam & water. Lid, flange & bottom plate is also made of SS, all joints are argon welded. Jointless silicon gasket. Heavy duty industrial flange heater. Lid fitting pressure gauge 0-30 PSI, safety spring loaded pressure valve, steam release valve. Safety high pressure release valve. Foot lifting arrangement is provided in 121C/D/E/F, a basket made of thick stainless steel (S.S.) rod wire mesh. Technical Specification : Semi automatic system for autoclave is supplied with microprocessor based digital temperature controller with an inbuilt timer. Low water level cuts off the system with magnetic oat switch for heaterâ??s safety. Fully automatic system for autoclave is supplied with microprocessor based digital temperature controller with an inbuilt timer. Low water level cuts off the system with magnetic oat switch for heater's safety.
The cryo baths are designed for research work and are provided with the circulating pump to ensure uniform temperature. TEMPO low temperature baths are designed for research work at the desired temperature with high accuracy. The temperature is controlled by microprocessor based PID controller with an accuracy of ±1C. The unit is provided with a circulation pump to ensure uniform temperature. Low temperature bath offers a combination of contemporary design, advance microcontroller and a range of accessories to suit your specific laboratory or process application. High strength cabinet construction with stainless steel interior tanks withstand the most critical applications in demanding laboratory environments. The unit is mounted on castor wheels for ease of mobility. Temperature range 0C to -20C Temperature accuracy ±1C Supply 230V, AC
The water baths are designed and manufactured to comply with the requirements of the various pharmaceutical and lab industries. â??TEMPOâ?? serological water bath have SS interior and powder coated mild steel exterior. The temperature is controlled by means of a precision thermostat. Temperature range 5 C above ambient to 60C
The water baths are designed and manufactured to comply with the requirements of the various pharmaceutical and lab industries. Tempo Water Bath have S.S. 316 Interior and S.S. 304 exterior. Temperature Range is from 5�°C above ambient to 99�°C max. Temperature is controlled by PID controller. Equipment is supplied with Pyramidal Lid. Temperature range â?? 5�°C above ambient to 99�°C Supply â?? 230V, AC Features : Safety temperature controller Low water level indicator Timer with alarm European plug Stainless Steel water drainage IP20 protection for control panel Drain for water supply Inlet nozzle for water filling
TEMPO make glass door refrigerators are stable and reliable with the refrigerated environment for exact laboratory requirements. Lab refrigerators are used for maintaining storage conditions of a product, to prevent its exposure to low temperature applications, where the temperature requirements are on the lower side. Ideal temperature environment for clinical research, pharmaceutical and industrial use. Adjustable shelves and wide range set point for varying laboratory applications including chromatography and pharmaceutical storage. The application includes refrigerated storage of vaccines, reagents, cultures, medicines and blood samples. Temperature range 2C to 8C Temperature accuracy ±0.5 C Temperature uniformity ±2 C Supply 230V, AC Controlling System : Microprocessor based auto tune PID temperature controller with a dual display of set value & process value for precise control of temperature. Sensor : PT 100 sensor is used for temperature & electronic type sensor for humidity. Heating System : High quality SS tubular heaters are used for better heating. Refrigeration System : CFC Free hermetically sealed Emerson Copeland make compressor for better cooling with R134 A (Eco Friendly) refrigerant with a time delay to safeguard compressor system.
TEMPO lab refrigerator is made of double walled construction with thick high grade PUF insulation. Full view inner acrylic door & front door with gasket & locking arrangement. The motorized blower at the backside of the chamber develops a unique airflow system to maintain uniform temperature condition inside the chamber. Unique airflow assures quick recovery after door openings. The unit is provided with a user friendly adjustable specially designed S.S rod trays, ensures uniform temperature distribution. The equipment is mounted on castor wheels for easy movement. Temperature range 2C to 8C Temperature accuracy ±0.5C Supply 230V, AC Controlling System By means of imported microprocessor based auto tuned PID controller with CE mark & dual display of set value & process value. Sensor PT 100 sensor is used for sensing the temperature. Heating System High quality S.S. tubular heaters are used for better heating. Refrigeration System CFC free hermetically sealed Emerson Copeland make compressor for better cooling with R134 A (eco-riendly) refrigerant with a time delay to safeguard compressor system. Validation Port : 50 mm validation porthole with silicon rubber seal to insert sensor for validation. Controlling System : By means of imported microprocessor based auto tuned PID controller with CE mark & dual display of set value & process value. Sensor : PT 100 sensor is used for sensing the temperature. Heating System : High quality S.S. tubular heaters are used for better heating. Refrigeration System : CFC free hermetically sealed Emerson Copeland make compressor for better cooling with R134 A (eco-friendly) refrigerant with a time delay to safeguard compressor system. Validation Port : 50 mm validation porthole with silicon rubber seal to insert sensor for validation.
TEMPO make bacteriological incubator are specially designed for research laboratories, engineering lab, pharmaceutical lab, cosmetic industry, chemical lab, clinical lab, microbiological determination, pharmaceutical stability assays, food processing, QC, etc. Temperature range 5 C above ambient to 80 C Temperature accuracy ±0.2 C Supply 230V, AC Controlling System : Microprocessor based auto tune PID temperature controller with a dual display of the value and process value for precise control of temperature with PT 100 sensor is used. Air Circulation (only forced air circulation) : The motorized blower at the backside of the chamber develops a unique airflow system which ensures maximum uniform temperature distribution inside the chamber. A unique airflow ensures quick recovery after the doors are opened. Heating System : Forced air circulation model â?? high quality SS tubular heaters are used for better heating conditions. Natural convection model the heating elements are made from the best quality Kanthal/Nichrome wire for refractory purpose.
TEMPO make BOD incubators are manufactured to comply requirement of industries. Specifically designed for the long term and stable continuous operation ideal for pharmaceuticals, biotechnology and research institutions for storage and incubation studies. Incubators to provide a condition for optimal growth of microbiology cultures, biological labs for the preservation of vaccines, serological and complement fixation tests, General low temperature uses in physical /chemical labs, R&D centre, quality control laboratory, general laboratories of industries, pharmaceuticals, chemicals, petrochemicals, oil & gas, cement, pulp and paper, fertilizers, defence, railways, paint etc. Temperature range â?? 5 C to 60 C Temperature accuracy â?? �±0.5 C Supply â?? 230V, AC Controlling System : Microprocessor based auto tune PID temperature controller with a dual display of set value & process value for precise control of temperature. Sensor : PT 100 sensor is used for sensing the temperature. Heating System : High quality S.S. tubular heaters are used for better heating. Humidity System : Steam injection system (non-condensing type) & reservoir tank with water level arrangement with indicator. Refrigeration System : CFC free hermetically sealed Emerson Copeland make compressor for better cooling with R134 A (eco-friendly) refrigerant with a time delay to safe guard compressor system. Validation Port : 50mm validation porthole with silicon rubber seal to insert sensor for validation.
When your testing requires a walk in rooms choose â??TEMPOâ?? controlled temperatures solution. Our test rooms feature automated process control, energy efficiency and a vast range of other features and options. Every â??TEMPOâ?? environmental room features equipment that reliably produces required conditions, structural integrity that keeps the room working properly through years of demanding test cycles, and measuring/monitoring equipment that precisely records all test data. Temperature range â?? 20 C to 60 C Temperature accuracy â?? �±0.2 C Temperature uniformity â?? �±1 C Humidity Range â?? 40% Rh to 95% Rh Humidity Accuracy â?? �±2%Rh Humidity Uniformity â?? �±3%Rh Air Circulation : The motorized blower at the backside of the chamber provides the recirculation of air which ensure the maximum uniformity of temperature and humidity inside the chamber should be maintained. Heating System : The high quality SS tubular heater made from the nichrome wire sheathed in SS tube is used. The special arrangement of heaters avoids the direct rendition of stored samples. Humidity System : High-quality U shape S.S. tubular heater is used for better heating. Humidity System : Steam injection system with water level arrangement is provided. A low pressure boiler tank and reservoir tank with duly argon welded is fitted with a float valve. When the water level in the tank is low the switch cut off. The ISI marked heating elements are used with the inbuilt stand by humidity system with auto change over the facility. Refrigeration System : The CFC Free hermetically sealed Emerson Copeland make compressor is used for better cooling with eco friendly refrigerant. The cooling system is made up of split type and the compressor is coupled with the condenser unit in a well ventilated area to avoid the hot air throw inside the chamber. Control System : The microprocessor based PLC (logging capacity of 1000 readings) with HMI touch screen 4.3â?³ colour display, which gives the direct display, the process value and the set value of temperature and humidity inside the chamber. The sensor (transmitter type 4-20 ma) which will accurately measure the temperature and humidity is provided with a high speed ethernet communication. The internal working area is illuminated.
When your testing requires a walk in rooms choose TEMPO controlled temperatures solution. Our test rooms feature automated process control, energy efficiency and a vast range of other features and options. Every TEMPO environmental room features equipment that reliably produces required conditions, structural integrity that keeps the room working properly through years of demanding test cycles, and measuring/monitoring equipment that precisely records all test data. Temperature range â?? 2 C to 8 C Temperature accuracy â?? �±0.5 C Temperature uniformity â?? �±2 C Control System : Microprocessor based PLC (up to 5000 readings) with 7â?³ touch screen colour HMI, which gives the direct display of process value and set the value of temperature and humidity inside the chamber. High speed ethernet based communication. Refrigeration System : The refrigeration is provided by means of CFC free hermetically sealed Emerson Copland compressor for better cooling with eco-friendly refrigerant. The cooling system is made up of split type so as one can place the compressor coupled with condenser unit in a well ventilated area to avoid hot air throw in the stability room. The inbuilt stand by refrigeration system is provided with auto change over the facility. Features : Negligible maintenance the sturdy design and long lasting finish ensures minimum maintenance for years. Minimal heat transferthe tongue and groove edges of all panels are moulded to close tolerance ensuring a tight fit between panels. These prevent condensation from forming on the foam and minimize heat transfer. Quality accessories hardware like hinges, handles etc. on panels from best indigenous suppliers.
TEMPO make vacuum oven are designed & manufactured to comply with the requirements of the industry. It is widely applicable for drying & sterilization in fields of biochemistry, pharmacy, medicine, health, agriculture & scientific research and environment protection. It is designed especially for the drying of material which is thermos sensitive or decompounded and oxidative easily. " Temperature range 50C to 200C " " Temperature accuracy ±0.2C " " Vacuum capacity can withstand a vacuum of 760 mm of mercury " " Supply 230V, AC " Controlling System : Microprocessor based auto tune PID temperature controller with a dual display of set value & process value for precise control of temperature. Heating System : Heating element made from best quality Kanthal DSD wire is used to develop unique temperature inside the chamber. Insulation : 4â?? high grade glass wool insulation for rectangular model & 3â?? high grade glass wool insulation for the circular model to minimized heat loss. Models & Optional Features : Circular vacuum oven with glass window of 7 diameter. Rectangular vacuum oven with glass window
TEMPO make humidity ovens are manufactured and design for electrical & electronic industries for testing components and equipment as per ISO 9000:2015 Testing cement, batteries, cigarettes, or any other material demanding controlled temperature & humidity. It is also used in industries like pharmaceutical for accelerating ageing, food & beverage, packing, department of botany, cytology, plant & animal breeding. Temperature range 5 C above ambient to 60 C Temperature accuracy ±0.5 C Temperature uniformity ±1 C Humidity Range 5% Rh above ambient to 90% Rh Humidity Accuracy ±2%Rh Humidity Uniformity ±3%Rh Controlling System : The temperature is controlled by means of imported microprocessors based autotune PID controller with CE mark & dual display of set value & process value. The humidity is controlled by means of imported microprocessors based autotune PID controller with CE mark & dual display of set value & process value with direct %RH. Air Circulation : The motorized blower at the backside of the chamber develops a unique air ow system which ensures maximum uniform temperature and humidity condition inside the chamber. The unique airflow assures quick recovery after the doors are opened. Heating System : High-quality U shape SS tubular heaters are used for better heating. Humidity System : Steam injection system (non-condensing type) & reservoir tank with water level arrangement with indicator.
TEMPO make TI 128HT series ovens are made of triple-walled construction. The motorized blower with V-belt fitted on the top side of the chamber for re-circulation of air to maintain the uniformity of temperature inside the chamber. The unit is insulated with 4 high grade glass wool. Single door fitted on heavy hinges. The unit is provided with user friendly adjustable stainless steel rod mesh trays. Temperature range 50 C to 450 C Temperature accuracy ±1 C Temperature uniformity ±1% of the set temperature Supply 230V, AC Controlling System : Two separate imported microprocessors based auto tune PID controller with CE mark & dual display of set value & process value for precise control of temperature. Air Circulation : The motorized blower with a V belt drive on the top side of the chamber develops the unique airflow distribution inside the chamber. The unique airflow system ensures quick recovery after the doors are opened. Heating System : High-quality U shape SS tubular heating elements used on the side walls to maintain uniform condition inside the chamber.
TEMPO make TI 128HT series ovens are made of triple-walled construction. The motorized blower with V-belt fitted on the top side of the chamber for re-circulation of air to maintain the uniformity of temperature inside the chamber. The unit is insulated with 4 high grade glass wool. Single door fitted on heavy hinges. The unit is provided with user friendly adjustable stainless steel rod mesh trays. Temperature range â?? 50 C to 400 C Temperature accuracy â?? �±1 C Temperature uniformity â?? �±1% of the set temperature Supply â?? 230V, AC TEMPO make TI â?? 128HT series ovens are made of triple walled construction. The motorized blower with V-Belt fitted on the top side of the chamber for re-circulation of air to maintain the uniformity of temperature inside the chamber. The unit is insulated with 4 high grade glass wool. Single door fitted on heavy hinges. The unit is provided with user friendly adjustable stainless steel rod mesh trays.