Product Details: Brand SD Biosensor Specimen Whole blood Specimen volume 1 mL Storage temperature 2-25 C / 36-77 F Cat No 07TBF10C Intented Use : Blood collection vacuum tube which is used with STANDARD E TB-Feron ELISA for diagnosis of latent tuberculosis infection Advantage: Specific detection of human IFN-I³ related to TB Sensitive and specific IGRA test
Sterile Duodenal Tube
Sterile Extension Tube
Sterile Ryle's Tube
Sterile Infant Feeding Tube
Sterile Levin's Tube
Tracheotomy Tube
Sterile Nasogastric Tube
Sterile Stomach Tube
All Surgery Tube Available Yankeur Suction Set Plain Tip CHEST DRAINAGE CATHETER Size FG- 10,12, 14, 16, 18, ABDOMINAL DARINAGE KIT Size FG- 12,14,16, 18,20, 22, 24,26 CLOSE WOUND SUCTION UNIT Adult 800 ml SURGICAL BLADES Size-Fitment No-3(10,10A,11,11P,12, 15 Size-Fitment No-4(20,21,22,23,24
2-Way Foley Balloon Catheter (PAPER PACK) Size: 12 FR To 18 FR 3-WAY FOLEY BALLOON CATHETER (PAPER PACK) Size 12 FR To 22 FR 100% SILICONE 2-WAY FOLEY BALLOON CATHETER Size 12 FR To 24 FR Urethral Red Rubber Catheter Size 12 FR To 24 FR T.U.R. Set Trans-Urethral Resection Of The Prostate NELTON CATHETER Size: 8 FG To 24 FG RECTAL CATHETER Size â?? 20, 22, 24,26,28,30 MALE EXTERNAL CATHETER Size Small, Medium, Large, Ex-Large. PEDIA URINE BAG UROMETER
Manufactured By: Plastx & P fact Unit size: 1 Pack size: 250 Pieces Volume: 2 ml
Vacuum Blood Collection Tube introduced by us promises to live up the expectations of the buyers. It is manufactured completely in clean room environment by using the best of the quality materials and assembled on a 100% Automatic assembly Line. We believe in quality and the same has been inculcated in our products. We produce the tubes in two volumes 13 75 mm and 13 100 mm. Variants : K2 EDTA (2 ml - 6 ml) K3 EDTA (2 ml - 6 ml) Clot Activator (2 ml - 6 ml) Sodium Heparin (2 ml - 6 ml) Lithium Heparin (2 ml - 6 ml) Sodium Fluoride (2 ml - 6 ml) Sodium Citrate (2 ml - 6 ml) Gel with Clot Activator (3.5 ml - 5 ml) We follow the colour codes of ISO 6710:2016 for the manufacturing process of the tube.
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%
Available in Vacuum and Non-vacuum types
Endotracheal Tube (Cuffed) Manufactured from siliconised non-toxic, non-irritant P.V.C. kink resistant thermo sensitive tube ensures tube patency for patient safety, yet softens at body temperature to conform to the anatomy of the respiratory tract. -Murphy eye has a polished smoothness ensuring atraumatic intubation and extubation. -Kink resistant inflation tube ensures patient safety during cuff inflation and deflation. -Soft low pressure cuff provides an air tight fit between tube and trachea. -X-ray opaque line and markings provided on the tube facilitate the exact location of the tube position. -Standard 15mm connector provided at proximal end. E.T.O. Sterile & Pyrogen Free. -Size: 2,2.5,3,3.5,4,4.5,5,5.5,6,6.5,7,7.5,8,8.5,9,9.5,10